Influence of calibration on digital templating of hip arthroplasty

被引:29
作者
Boese, Christoph Kolja [1 ]
Wilhelm, Sebastian [1 ]
Haneder, Stefan [2 ]
Lechler, Philipp [3 ]
Eysel, Peer [1 ]
Bredow, Jan [4 ,5 ]
机构
[1] Univ Hosp Cologne, Dept Orthopaed & Trauma Surg, Joseph Stelzmann Str 9, D-50924 Cologne, Germany
[2] Univ Hosp Cologne, Inst Diagnost & Intervent Radiol, Cologne, Germany
[3] Univ Giessen & Marburg, Ctr Orthoped & Trauma Surg, Marburg, Germany
[4] Schon Klin Dusseldorf, Dept Spine Surg, Dusseldorf, Germany
[5] Schon Klin Dusseldorf SE & Co KG, Ctr Orthoped, Heerdter Krankenhaus 2, D-40549 Dusseldorf, Germany
关键词
Total hip arthroplasty; Digital templating; Radiography; Calibration; ACCURACY; REPLACEMENT; MARKERS; KNEE;
D O I
10.1007/s00264-018-4120-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
IntroductionDigital templating for total joint replacement is the current standard. For image calibration, external calibration markers (ECM) are used. However, there are concerns regarding the precision of the method. This study aimed to identify the direct influence of calibration errors on digital templating.Patients and methodsA retrospective analysis of 100 post-operative radiographs with unilateral total hip arthroplasty was performed. The magnification factor of the ECM and of the internal prosthetic femoral head (ICM) as a reference value was calculated for each radiograph. Two blinded observers performed templating of the contralateral hip using a randomized list for all radiographs and both markers. The component size templated by the ECM magnification was compared to the reference by the ICM magnification.ResultsMean magnification factors of ICM and ECM differed significantly (p=0.006). The absolute difference was 5.2% (range 0.0-23.3%, SD 4.8%). Templating of the acetabular or the femoral component showed no significant differences (p=0.120, p=0.599). Differences of more than one size were found in 26% of the acetabular components and 14% of the femoral components and differences over two sizes in 10% respectively 3%. Correlation coefficients for magnification error and size differences of acetabular components were -0.645 (p<0.001) and for the femoral component -0.607 (p<0.001).InterpretationThe calibration error of external calibration markers in digital templating for hip replacement influences component sizes significantly. Thus, correct positioning of ECM is of utmost importance.
引用
收藏
页码:1799 / 1805
页数:7
相关论文
共 17 条
[1]   Prospective, Randomized, Surgeon-Blinded Comparison of Standard Magnification Assumption vs Magnification Marker Usage for Preoperative Templating in Total Hip Arthroplasty [J].
Archibeck, Michael J. ;
Tripuraneni, Krishna R. ;
Carothers, Joshua T. ;
Junick, Daniel W. ;
Munson, Natalie R. ;
Murray-Krezan, Cristina M. .
JOURNAL OF ARTHROPLASTY, 2017, 32 (10) :3061-3064
[2]   The accuracy of automatic calibration of digital pelvic radiographs using two different scale markers: a comparative study [J].
Baxter, Jonathan A. ;
Barlow, Timothy ;
Karthikeyan, Shanmugam ;
Mayo, Damian J. ;
King, Richard J. .
HIP INTERNATIONAL, 2012, 22 (01) :82-89
[3]   Evaluation of the Accuracy and Use of X-Ray Markers in Digital Templating for Total Hip Arthroplasty [J].
Bayne, Christopher O. ;
Krosin, Michael ;
Barber, Thomas C. .
JOURNAL OF ARTHROPLASTY, 2009, 24 (03) :407-413
[4]   Calibration Marker Position in Digital Templating of Total Hip Arthroplasty [J].
Boese, Christoph K. ;
Bredow, Jan ;
Dargel, Jens ;
Eysel, Peer ;
Geiges, Hansjoerg ;
Lechler, Philipp .
JOURNAL OF ARTHROPLASTY, 2016, 31 (04) :883-887
[5]   Dual-position calibration markers for total hip arthroplasty: theoretical comparison to fixed calibration and single marker method [J].
Boese, Christoph Kolja ;
Wilhelm, Sebastian ;
Haneder, Stefan ;
Lechler, Philipp ;
Eysel, Peer ;
Bredow, Jan .
INTERNATIONAL ORTHOPAEDICS, 2019, 43 (03) :589-595
[6]   Calibration Markers for Digital Templating in Total Hip Arthroplasty [J].
Boese, Christoph Kolja ;
Lechler, Philipp ;
Rose, Leonard ;
Dargel, Jens ;
Oppermann, Johannes ;
Eysel, Peer ;
Geiges, Hansjoerg ;
Bredow, Jan .
PLOS ONE, 2015, 10 (07)
[7]  
Efe T, 2011, ACTA ORTHOP BELG, V77, P616
[8]   A comparison of four systems for calibration when templating for total hip replacement with digital radiography [J].
Franken, M. ;
Grimm, B. ;
Heyligers, I. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2010, 92B (01) :136-141
[9]   The Accuracy of Digital Templating in Uncemented Total Hip Arthroplasty [J].
Gamble, Patrick ;
de Beer, Justin ;
Petruccelli, Danielle ;
Winemaker, Mitchell .
JOURNAL OF ARTHROPLASTY, 2010, 25 (04) :529-532
[10]   A Comparison of Acetate vs Digital Templating for Preoperative Planning of Total Hip Arthroplasty [J].
Iorio, Richard ;
Siegel, Jodi ;
Specht, Lawrence M. ;
Tilzey, John F. ;
Hartman, Audrey ;
Healy, William L. .
JOURNAL OF ARTHROPLASTY, 2009, 24 (02) :175-179