Intensified nitrogen and phosphorus removal by embedding electrolysis in an anaerobic-anoxic-oxic reactor treating low carbon/nitrogen wastewater

被引:35
作者
Gong, Benzhou [1 ]
Wang, Yingmu [1 ]
Wang, Jiale [1 ]
Huang, Wei [1 ]
Zhou, Jian [1 ,2 ]
He, Qiang [1 ,2 ]
机构
[1] Chongqing Univ, Fac Urban Construct & Environm Engn, Chongqing 400045, Peoples R China
[2] Chongqing Univ, Minist Educ, Key Lab Thress Gorges Reservoirs Ecoenvironm, Chongqing 400045, Peoples R China
关键词
Electrolysis; Nitrogen and phosphorus removal; Low carbon/nitrogen wastewater; AAO; ACTIVATED-SLUDGE; PERFORMANCE; PRECIPITATION; TECHNOLOGIES; PHOSPHATE; RECOVERY; SYSTEMS; CARBON; IRON;
D O I
10.1016/j.biortech.2018.02.014
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
A modified anaerobic-anoxic-oxic (AAO) reactor embedding electrolysis was constructed for treatment of low carbon/nitrogen (C/N) wastewater. The effect of different current conditions on the performance of reactor was investigated in this study. When the current ranged from 0 mA to 200 mA, the removal efficiency of total nitrogen (TN) increased from 61.25% (0 mA) to 75.60% (200 mA), and that of total phosphorus (TP) increased from 72.24% (0 mA) to 93.93% (200 mA). In addition, the removal efficiencies of chemical oxygen demand (COD) and NH4+-N were not affected. The results indicated that AAO reactor coupling electrolysis was an effective way to strengthen the removal of nitrogen and phosphorus for treatment of low C/N wastewater.
引用
收藏
页码:562 / 565
页数:4
相关论文
共 17 条
[1]  
[Anonymous], 2006, STANDARD METHODS EXA, DOI DOI 10.5860/CHOICE.37-2792
[2]  
de Haas DW, 2001, WATER SA, V27, P117
[3]   Precipitation of iron-hydroxy-phosphate of added ferric iron from domestic wastewater by an alternating aerobic-anoxic process [J].
Fulazzaky, Mohamad Ali ;
Salim, Nur Atikah Abdul ;
Abdullah, Noorul Hudai ;
Yusoff, Abdull Rahim Mohd ;
Paul, Etienne .
CHEMICAL ENGINEERING JOURNAL, 2014, 253 :291-297
[4]   Intensified nitrate and phosphorus removal in an electrolysis-integrated horizontal subsurface-flow constructed wetland [J].
Gao, Y. ;
Xie, Y. W. ;
Zhang, Q. ;
Wang, A. L. ;
Yu, Y. X. ;
Yang, L. Y. .
WATER RESEARCH, 2017, 108 :39-45
[5]   High performance of nitrogen and phosphorus removal in an electrolysis-integrated biofilter [J].
Gao, Y. ;
Xie, Y. W. ;
Zhang, Q. ;
Yu, Y. X. ;
Yang, L. Y. .
WATER SCIENCE AND TECHNOLOGY, 2016, 74 (03) :714-721
[6]   Detection of nitrifiers and evaluation of partial nitrification for wastewater treatment: A review [J].
Ge, Shijian ;
Wang, Shanyun ;
Yang, Xiong ;
Qiu, Shuang ;
Li, Baikun ;
Peng, Yongzhen .
CHEMOSPHERE, 2015, 140 :85-98
[7]   Nutrients removal and recovery in bioelectrochemical systems: A review [J].
Kelly, Patrick T. ;
He, Zhen .
BIORESOURCE TECHNOLOGY, 2014, 153 :351-360
[8]   Treatment of nitrate contaminated water using an electrochemical method [J].
Li, Miao ;
Feng, Chuanping ;
Zhang, Zhenya ;
Yang, Shengjiong ;
Sugiura, Norio .
BIORESOURCE TECHNOLOGY, 2010, 101 (16) :6553-6557
[9]   Performance of an anoxic reactor proposed before BAF: Effect of ferrous sulfate on enhancing denitrification during simultaneous phosphorous removal [J].
Li, Ting ;
Wang, Hongjie ;
Dong, Wengyi ;
Liu, Tongzhou ;
Ouyang, Feng ;
Zhang, Qian ;
Dong, Xiaoqing .
CHEMICAL ENGINEERING JOURNAL, 2014, 248 :41-48
[10]   Review: Phosphorus removal and recovery technologies [J].
Morse, GK ;
Brett, SW ;
Guy, JA ;
Lester, JN .
SCIENCE OF THE TOTAL ENVIRONMENT, 1998, 212 (01) :69-81