Evaluation of the Respimat Soft Mist Inhaler using a Concurrent CFD and In Vitro Approach

被引:91
作者
Longest, P. Worth [1 ,2 ]
Hindle, Michael [2 ]
机构
[1] Virginia Commonwealth Univ, Dept Mech Engn, Richmond, VA 23284 USA
[2] Virginia Commonwealth Univ, Dept Pharmaceut, Richmond, VA 23284 USA
关键词
softmist inhalers; aerosol transport and deposition; USP induction port; mouth-throat geometry; respiratory aerosol dynamics; respiratory drug delivery; spray aerosols; inhaler mouthpiece design; METERED-DOSE INHALER; LOW-REYNOLDS-NUMBER; BROMIDE PLUS FENOTEROL; PARTICLE DEPOSITION; MOUTH-THROAT; SOFT-MIST(TM) INHALER; AEROSOL DEPOSITION; TURBULENT FLOWS; LUNG DEPOSITION; MODELS;
D O I
10.1089/jamp.2008.0708
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background: The Respimat Soft Mist Inhaler is reported to generate an aerosol with low spray momentum and a small droplet size. However, the transport characteristics of the Respimat aerosol are not well understood. The objective of this study was to characterize the transport and deposition of an aerosol emitted from the Respimat inhaler using a combination of computational fluid dynamics (CFD) modeling and in vitro experiments. Methods: Deposition of the Respimat aerosol was assessed in the inhaler mouthpiece (MP), a standard induction port (IP), and a more realistic mouth-throat (MT) geometry at an inhalation flow rate of 30 L/min. Aerosols were generated using an albuterol sulfate (0.6%) solution, and the drug deposition was quantified using both in vitro experiments and a CFD model of the Respimat inhaler. Laser diffraction experiments were used to determine the initial polydisperse aerosol size distribution. Results and Conclusions: It was found that the aerosol generated from the highly complex process of jet collision and breakup could be approximated in the model using effective spray conditions. Computational predictions of deposition fractions agreed well with in vitro results for both the IP (within 20% error) and MT (within 10% error) geometries. The experimental results indicated that the deposition fraction of drug in the MP ranged from 27 to 29% and accounted for a majority of total drug loss. Based on the CFD solution, high MP deposition was due to a recirculating flow pattern that surrounded the aerosol spray and entrained a significant number of small droplets. In contrast, deposition of the Respimat aerosol in both the IP (4.2%) and MT (7.4%) geometries was relatively low. Results of this study indicate that modifications to the current Respimat MP and control of specific patient variables may significantly reduce deposition in the device and may decrease high oropharyngeal drug loss observed in vivo.
引用
收藏
页码:99 / 112
页数:14
相关论文
共 57 条
[1]   Degree of throat deposition can explain the variability in lung deposition of inhaled drugs [J].
Borgstrom, Lars ;
Olsson, Bo ;
Thorsson, Lars .
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 2006, 19 (04) :473-483
[2]  
Byron Peter R, 2004, Proc Am Thorac Soc, V1, P321, DOI 10.1513/pats.200403-023MS
[3]   Measurements of airway dimensions and calculation of mass transfer characteristics of the human oral passage [J].
Cheng, KH ;
Cheng, YS ;
Yeh, HC ;
Swift, DL .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1997, 119 (04) :476-482
[4]   Respiratory deposition patterns of salbutamol pMDI with CFC and HFA-134a formulations in a human airway replica [J].
Cheng, YS ;
Fu, CS ;
Yazzie, D ;
Zhou, Y .
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 2001, 14 (02) :255-266
[5]  
CONWAY J, 2002, RESP DRUG DEL, V8, P189
[6]  
Crowe C., 1998, Multiphase Flows with Droplets and Particles
[7]   Numerical models for two-phase turbulent flows [J].
Crowe, CT ;
Troutt, TR ;
Chung, JN .
ANNUAL REVIEW OF FLUID MECHANICS, 1996, 28 :11-43
[8]   Systemic side effects of inhaled corticosteroids in patients with asthma [J].
Dahl, Ronald .
RESPIRATORY MEDICINE, 2006, 100 (08) :1307-1317
[9]   A review of the development of Respimat® Soft Mist™ Inhaler [J].
Dalby, R ;
Spallek, M ;
Voshaar, T .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2004, 283 (1-2) :1-9
[10]   Aerosol plumes: Slow and steady wins the race [J].
Dhand, R .
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 2005, 18 (03) :261-263