Real-time magnetic resonance imaging - guided coronary intervention in a porcine model

被引:27
作者
Heidt, Timo [1 ,2 ]
Reiss, Simon [3 ]
Krafft, Axel J. [3 ]
Oezen, Ali Caglar [3 ]
Lottner, Thomas [3 ]
Hehrlein, Christoph [1 ,2 ]
Galmbacher, Roland [4 ]
Kayser, Gian [5 ]
Hilgendorf, Ingo [1 ,2 ]
Stachon, Peter [1 ,2 ]
Wolf, Dennis [1 ,2 ]
Zirlik, Andreas [1 ,2 ]
Duering, Klaus [6 ]
Zehender, Manfred [1 ,2 ]
Meckel, Stephan [7 ]
von Elverfeldt, Dominik [3 ]
Bode, Christoph [1 ,2 ]
Bock, Michael [3 ]
von zur Muehlen, Constantin [1 ,2 ]
机构
[1] Freiburg Univ, Cardiol & Angiol 1, Heart Ctr, Freiburg, Germany
[2] Fac Med, Freiburg, Germany
[3] Univ Med Ctr Freiburg, Fac Med, Dept Radiol, Med Phys, Freiburg, Germany
[4] Univ Hosp Heidelberg, Dept Expt Anesthesiol, Heidelberg, Germany
[5] Univ Med Ctr Freiburg, Fac Med, Inst Surg Pathol, Dept Pathol, Freiburg, Germany
[6] MaRVis Intervent GmbH, Frechen, Germany
[7] Univ Med Ctr Freiburg, Fac Med, Dept Neuroradiol, Freiburg, Germany
关键词
ACTIVE CATHETER TRACKING; FEASIBILITY;
D O I
10.1038/s41598-019-45154-7
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
X-ray fluoroscopy is the gold standard for coronary diagnostics and intervention. Magnetic resonance imaging is a radiation-free alternative to x-ray with excellent soft tissue contrast in arbitrary slice orientation. Here, we assessed real-time MRI-guided coronary interventions from femoral access using newly designed MRI technologies. Six Goettingen minipigs were used to investigate coronary intervention using real-time MRI. Catheters were custom-designed and equipped with an active receive tip-coil to improve visibility and navigation capabilities. Using modified standard clinical 5 F catheters, intubation of the left coronary ostium was successful in all animals. For the purpose of MR-guided coronary interventions, a custom-designed 8 F catheter was used. In spite of the large catheter size, and therefore limited steerability, intubation of the left coronary ostium was successful in 3 of 6 animals within seconds. Thereafter, real-time guided implantation of a non-metallic vascular scaffold into coronary arteries was possible. This study demonstrates that real-time MRI-guided coronary catheterization and intervention via femoral access is possible without the use of any contrast agents or radiation, including placement of non-metallic vascular scaffolds into coronary arteries. Further development, especially in catheter and guidewire technology, will be required to drive forward routine MR-guided coronary interventions as an alternative to x-ray fluoroscopy.
引用
收藏
页数:10
相关论文
共 50 条
[41]   Coronary Events Following Dobutamine Stress Cardiac Magnetic Resonance Imaging in Pediatric Patients [J].
Beattie, Meaghan ;
Beroukhim, Rebecca ;
Annese, David ;
Dionne, Audrey ;
Baker, Annette ;
Powell, Andrew J. .
PEDIATRIC CARDIOLOGY, 2024,
[42]   Magnetic resonance imaging-guided ultrasound ablation for prostate cancer - A contemporary review of performance [J].
Alabousi, Mostafa ;
Ghai, Sangeet .
FRONTIERS IN ONCOLOGY, 2023, 12
[43]   A Passive Parallel Master-Slave Mechanism for Magnetic Resonance Imaging-Guided Interventions [J].
Elayaperumal, Santhi ;
Cutkosky, Mark R. ;
Renaud, Pierre ;
Daniel, Bruce L. .
JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2015, 9 (01)
[44]   Real-Time Classification of Hand Motions Using Ultrasound Imaging of Forearm Muscles [J].
Akhlaghi, Nima ;
Baker, Clayton A. ;
Lahlou, Mohamed ;
Zafar, Hozaifah ;
Murthy, Karthik G. ;
Rangwala, Huzefa S. ;
Kosecka, Jana ;
Joiner, Wilsaan M. ;
Pancrazio, Joseph J. ;
Sikdar, Siddhartha .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2016, 63 (08) :1687-1698
[45]   Combined Magnetic Resonance Elastography and Collagen Molecular Magnetic Resonance Imaging Accurately Stage Liver Fibrosis in a Rat Model [J].
Zhu, Bo ;
Wei, Lan ;
Rotile, Nicholas ;
Day, Helen ;
Rietz, Tyson ;
Farrar, Christian T. ;
Lauwers, Gregory Y. ;
Tanabe, Kenneth K. ;
Rosen, Bruce ;
Fuchs, Bryan C. ;
Caravan, Peter .
HEPATOLOGY, 2017, 65 (03) :1015-1025
[46]   Adaptive model-predictive controller for magnetic resonance guided focused ultrasound therapy [J].
de Bever, Joshua ;
Todd, Nick ;
Payne, Allison ;
Christensen, Douglas A. ;
Roemer, Robert B. .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2014, 30 (07) :456-470
[47]   Real-time spectral CT thermometry via physical density for image guided tumor ablation [J].
Liu, Leening P. ;
Hung, Matthew ;
Soulen, Michael C. ;
Noel, Peter B. ;
Shapira, Nadav .
MEDICAL IMAGING 2022: PHYSICS OF MEDICAL IMAGING, 2022, 12031
[48]   Magnetic resonance imaging-guided lumbar nerve root infiltrations: optimization of an in-house protocol [J].
Scheffler, Max ;
Guillemin, Pauline Coralie ;
Lorton, Orane ;
Maturana, Enrique ;
Lauper, Nicolas ;
Dominguez, Dennis E. ;
Terraz, Sylvain ;
Poletti, Pierre-Alexandre ;
Salomir, Rares ;
Boudabbous, Sana .
BMC MEDICAL IMAGING, 2021, 21 (01)
[49]   Magnetic resonance imaging ultrasonography fusion-guided transforaminal epidural steroid injection: a retrospective cohort [J].
Sumen, Ahmet ;
Oktay, Kubra Neslihan Kurt .
EUROPEAN SPINE JOURNAL, 2025, 34 (04) :1552-1561
[50]   First Magnetic Resonance Imaging-Guided Aortic Stenting and Cava Filter Placement Using a Polyetheretherketone-Based Magnetic Resonance Imaging-Compatible Guidewire in Swine: Proof of Concept [J].
Kos, Sebastian ;
Huegli, Rolf ;
Hofmann, Eugen ;
Quick, Harald H. ;
Kuehl, Hilmar ;
Aker, Stephanie ;
Kaiser, Gernot M. ;
Borm, Paul J. A. ;
Jacob, Augustinus L. ;
Bilecen, Deniz .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2009, 32 (03) :514-521