Miniature scintillating detector for small field radiation therapy

被引:86
作者
Létourneau, D
Pouliot, J
Roy, R
机构
[1] Univ Quebec, Ctr Hosp, Quebec City, PQ G1R 2J6, Canada
[2] Univ Laval, Dept Phys, St Foy, PQ G1K 7P4, Canada
关键词
scintillator; stereotactic radiosurgery;
D O I
10.1118/1.598793
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In planning stereotactic radiosurgery treatments, depth dose curves, profiles, and dose rate of treatment beams are difficult to obtain with conventional detectors because of loss of lateral electronic equilibrium and volume averaging. A scintillating detector with high spatial resolution and good reliability has been developed to overcome this problem. The miniature dosimeter consists of two identical radiation-resistant 10 m long silica optical fibers, each connected to an independent silicon photodiode. A small cylindrical polystyrene scintillator (3.9 mm(3)) is optically glued to the detection fiber. The light seen by the photodiode connected to this fiber arises from fluorescence of the scintillator and from the Cerenkov effect produced in silica. The reference signal produced by the fiber without scintillator is used to subtract the Cerenkov light contribution from the raw detector response. The sensitive volume of the scintillating detector is nearly water-equivalent and thus minimizes dose distribution perturbation in water. The miniature dosimeter has a spatial resolution comparable to the film-densitometer system. Profiles of 1 cm diam, 6 MV photon beam measured with both systems show very similar shapes. Furthermore, the use of photodiodes instead of photomultiplier tubes gives a better stability response and offers the possibility to perform absolute dosimetry. (C) 1999 American Association of Physicists in Medicine. [S0094-2405(99)02112-4].
引用
收藏
页码:2555 / 2561
页数:7
相关论文
共 8 条
[1]   Radiation-induced light in optical fibers and plastic scintillators: Application to brachytherapy dosimetry [J].
Arnfield, MR ;
Gaballa, HE ;
Zwicker, RD ;
Islam, Q ;
SchmidtUllrich, R .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (03) :2077-2084
[2]   WATER-EQUIVALENT PLASTIC SCINTILLATION DETECTORS FOR HIGH-ENERGY BEAM DOSIMETRY .2. PROPERTIES AND MEASUREMENTS [J].
BEDDAR, AS ;
MACKIE, TR ;
ATTIX, FH .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (10) :1901-1913
[3]   WATER-EQUIVALENT PLASTIC SCINTILLATION DETECTORS FOR HIGH-ENERGY BEAM DOSIMETRY .1. PHYSICAL CHARACTERISTICS AND THEORETICAL CONSIDERATIONS [J].
BEDDAR, AS ;
MACKIE, TR ;
ATTIX, FH .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (10) :1883-1900
[4]   ABSORBED DOSE PERTURBATION CAUSED BY DIODES FOR SMALL-FIELD PHOTON DOSIMETRY [J].
BEDDAR, AS ;
MASON, DJ ;
OBRIEN, PF .
MEDICAL PHYSICS, 1994, 21 (07) :1075-1079
[5]   CERENKOV LIGHT GENERATED IN OPTICAL FIBERS AND OTHER LIGHT PIPES IRRADIATED BY ELECTRON-BEAMS [J].
BEDDAR, AS ;
MACKIE, TR ;
ATTIX, FH .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (04) :925-935
[6]   OPTICAL FILTERING AND SPECTRAL MEASUREMENTS OF RADIATION-INDUCED LIGHT IN PLASTIC SCINTILLATION DOSIMETRY [J].
DEBOER, SF ;
BEDDAR, AS ;
RAWLINSON, JA .
PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (07) :945-958
[7]  
Jelly J. V., 1958, CERENKOV RAD ITS APP
[8]  
Leo WR, 1994, TECHNIQUES NUCL PART