Clinical single-shot diffusion-weighted MRI of the human brain on a short-bore medium-field imager

被引:7
作者
Lövblad, KO
Remonda, L
Heid, O
Schneider, J
Gönner, F
Schroth, G
机构
[1] Univ Bern, Inselspital, Inst Radiol, NRAD IDR C212,Dept Neuroradiol, CH-3010 Bern, Switzerland
[2] Siemens Med Syst Inc, Erlangen, Germany
关键词
stroke; magnetic resonance imaging; diffusion-weighted imaging;
D O I
10.1007/s002340050861
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Diffusion-weighted MRI (DWI) is becoming important for assessment of acute stroke. Until recently single-shot DWI required expensive technology such as echo-planar imaging (EPI) available only at some research sites. A new medium-field (1.0 T) short-bore MR imager has been developed with which DWI data sets can be acquired. We prospectively studied 169 patients on this 1.0 T commercial system. After conventional imaging, DWI was performed with a single-shot multi-slice sequence with b values 0 an 900 s/mm(2), and with the gradients switched in three directions. The apparent diffusion coefficients were calculated with online calculation software. There were 50 patients with totally normal MRI, and 17 had strokes, these strokes were detected as areas of high signal on the images at a maximal b value. There was a drop in the ADC in ischaemic regions: in sub-acute infarcts, the values were between 0.41 and 0.531 x 10(-3) mm(2)/s. In old infarcts the ADC was 1.15 x 10-3 mm(2)/s. Cerebrospinal fluid (CSF) gave low signal whereas areas in the brain had more intermediate intensities (CSF) 3.00; deep white matter: 0.75, cortical grey matter: 0.80, basal ganglia (thalamus): 0.70 and cerebellar white matter: 0.65 x 10(-3) mm(2)/s. Anisotropy was detected as areas of restricted diffusion along the tracts. These preliminary data show that DWI can be aquired successfully on a medium-field short-bore system. This should allow the technique to be implemented at more sites, therefore facilitating the diagnosis of acute stroke and rendering early intervention feasible.
引用
收藏
页码:889 / 894
页数:6
相关论文
共 29 条
  • [1] STROKE WITH NEGATIVE BRAIN MAGNETIC-RESONANCE-IMAGING
    ALBERTS, MJ
    FAULSTICH, ME
    GRAY, L
    [J]. STROKE, 1992, 23 (05) : 663 - 667
  • [2] MULTI-PLANAR IMAGE-FORMATION USING NMR SPIN ECHOES
    MANSFIELD, P
    [J]. JOURNAL OF PHYSICS C-SOLID STATE PHYSICS, 1977, 10 (03): : L55 - L58
  • [3] Enlargement of human cerebral ischemic lesion volumes measured by diffusion-weighted magnetic resonance imaging
    Baird, AE
    Benfield, A
    Schlaug, G
    Siewert, B
    Lovblad, KO
    Edelman, RR
    Warach, S
    [J]. ANNALS OF NEUROLOGY, 1997, 41 (05) : 581 - 589
  • [4] ANISOTROPIC DIFFUSION IN HUMAN WHITE MATTER - DEMONSTRATION WITH MR TECHNIQUES INVIVO
    CHENEVERT, TL
    BRUNBERG, JA
    PIPE, JG
    [J]. RADIOLOGY, 1990, 177 (02) : 401 - 405
  • [5] CHIEN D, 1992, AM J NEURORADIOL, V13, P1097
  • [6] Hemorrhagic and nonhemorrhagic stroke: Diagnosis with diffusion-weighted and T2-weighted echo-planar MR imaging
    Ebisu, T
    Tanaka, C
    Umeda, M
    Kitamura, M
    Fukunaga, M
    Aoki, I
    Sato, H
    Higuchi, T
    Naruse, S
    Horikawa, Y
    Ueda, S
    [J]. RADIOLOGY, 1997, 203 (03) : 823 - 828
  • [7] EVOLVING TOWARD EFFECTIVE THERAPY FOR ACUTE ISCHEMIC STROKE
    FISHER, M
    BOGOUSSLAVSKY, J
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1993, 270 (03): : 360 - 364
  • [8] Line scan diffusion imaging
    Gudbjartsson, H
    Maier, SE
    Mulkern, RV
    Morocz, IA
    Patz, S
    Jolesz, FA
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (04) : 509 - 519
  • [9] MR IMAGING OF INTRAVOXEL INCOHERENT MOTIONS - APPLICATION TO DIFFUSION AND PERFUSION IN NEUROLOGIC DISORDERS
    LEBIHAN, D
    BRETON, E
    LALLEMAND, D
    GRENIER, P
    CABANIS, E
    LAVALJEANTET, M
    [J]. RADIOLOGY, 1986, 161 (02) : 401 - 407
  • [10] Lovblad KO, 1998, AM J NEURORADIOL, V19, P201