摘要
Functional magnetic resonance imaging (fMRI) is increasingly used in cognitive studies. Unfortunately, the scanner produces acoustic noise during the image acquisition process. Interference from acoustic noise is known to affect auditory, visual and motor processing, raising the possibility that acoustic interference may also modulate processing of other sensory modalities such as pain. With the increasing use of fMRI in the investigation of the mechanisms of pain perception, particularly in relation to attention, this issue has become highly relevant. Pain is a complex experience, composed of sensory-discriminative, affective motivational and cognitive-evaluative components. The aim of this experiment was to assess the effect of MRI scanner noise, compared to white noise, on the affective (unpleasantness) and the sensory-discriminative (localisation) components of pain. Painful radiant heat from a CO2 laser was delivered to the skin of the right forearm in 24 healthy volunteers. The volunteers attended to either pain location or pain unpleasantness during three conditions: i) no noise, ii) exposure to MRI scanner noise (85 dB) or iii) exposure to white noise (85 dB). Both MRI scanner noise and white noise significantly reduced unpleasantness ratings (from 5.1 +/- 1.6 in the control condition to 4.7 +/- 1.5 (P = 0.002) and 4.6 +/- 1.6 (P < 0.001) with scanner and white noise respectively), whereas the ability to localise pain was not significantly affected (from 85.4 +/- 9.2% correct in the control condition to 83.1 +/- 10.3% (P = 0.06) and 83.9 +/- 9.5% (P = 0.27) with MRI scanner and white noise respectively). This phenomenon should be taken into account in the design of fMRI studies into human pain perception. (c) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:1278 / 1283
页数:6
相关论文
共 50 条
  • [1] Acoustic noise concerns in functional magnetic resonance imaging
    Moelker, A
    Pattynama, PMT
    HUMAN BRAIN MAPPING, 2003, 20 (03) : 123 - 141
  • [2] Functional magnetic resonance imaging evaluation of lumbosacral radiculopathic pain
    Koefman, Alex J.
    Licari, Melissa
    Bynevelt, Michael
    Lind, Christopher R. P.
    JOURNAL OF NEUROSURGERY-SPINE, 2016, 25 (04) : 517 - 522
  • [3] FUNCTIONAL MAGNETIC RESONANCE IMAGING STUDIES IN PAIN RESEARCH
    Edes Andrea Edit
    Juhasz Gabriella
    IDEGGYOGYASZATI SZEMLE-CLINICAL NEUROSCIENCE, 2016, 69 (9-10): : 307 - 312
  • [4] Parallel Imaging-Based Reduction of Acoustic Noise for Clinical Magnetic Resonance Imaging
    Pierre, Eric Y.
    Grodzki, David
    Aandal, Gunhild
    Heismann, Bjoern
    Badve, Chaitra
    Gulani, Vikas
    Sunshine, Jeffrey L.
    Schluchter, Mark
    Liu, Kecheng
    Griswold, Mark A.
    INVESTIGATIVE RADIOLOGY, 2014, 49 (09) : 620 - 626
  • [5] Transforming Pain With Prosocial Meaning: A Functional Magnetic Resonance Imaging Study
    Lopez-Sola, Marina
    Koban, Leonie
    Wager, Tor D.
    PSYCHOSOMATIC MEDICINE, 2018, 80 (09): : 814 - 825
  • [6] A comparison of visceral and somatic pain processing in the human brainstem using functional magnetic resonance imaging
    Dunckley, P
    Wise, RG
    Fairhurst, M
    Hobden, P
    Aziz, Q
    Chang, L
    Tracey, I
    JOURNAL OF NEUROSCIENCE, 2005, 25 (32) : 7333 - 7341
  • [7] Functional magnetic resonance imaging in anaesthesia research
    Pattinson, K. T. S.
    BRITISH JOURNAL OF ANAESTHESIA, 2013, 111 (06) : 872 - 876
  • [8] Functional Magnetic Resonance Imaging
    Shah, Lubdha M.
    Anderson, Jeffrey S.
    Lee, James N.
    Wiggins, Richard, III
    SEMINARS IN ROENTGENOLOGY, 2010, 45 (02) : 147 - 156
  • [9] Physiological noise reduction using volumetric functional magnetic resonance inverse imaging
    Lin, Fa-Hsuan
    Nummenmaa, Aapo
    Witzel, Thomas
    Polimeni, Jonathan R.
    Zeffiro, Thomas A.
    Wang, Fu-Nien
    Belliveau, John W.
    HUMAN BRAIN MAPPING, 2012, 33 (12) : 2815 - 2830
  • [10] Brainstem Functional Magnetic Resonance Imaging: Disentangling Signal From Physiological Noise
    Harvey, Ann K.
    Pattinson, Kyle T. S.
    Brooks, Jonathan C. W.
    Mayhew, Stephen D.
    Jenkinson, Mark
    Wise, Richard G.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 28 (06) : 1337 - 1344