Parallel-hole collimator concept for stationary SPECT imaging

被引:5
作者
Pato, Lara R. V. [1 ]
Vandenberghe, Stefaan [1 ]
Zedda, Tiziana [1 ]
Van Holen, Roel [1 ]
机构
[1] Univ Ghent, MEDISIP, Dept Elect & Informat Syst, IMinds IBiTech, B-9000 Ghent, Belgium
关键词
single photon emission computed tomography; collimator design; modeling and simulation; PINHOLE COLLIMATOR; SYSTEM; DESIGN;
D O I
10.1088/0031-9155/60/22/8791
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Parallel-hole SPECT collimators have traditionally been manufactured by stacking sheets of lead foil or by casting. These techniques significantly restrict our options in terms of collimator geometry. However, recent developments in metal additive manufacturing are making novel collimator designs possible, giving rise to new opportunities in SPECT imaging. In this paper we propose an innovative type of collimator for stationary SPECT, using parallel-holes whose collimation direction depends on their axial position. Its main advantage compared to current stationary SPECT systems (which are based on pinholes) is that, using only axial bed translations, we can achieve complete angular sampling of an increased portion of the transaxial area of the collimator bore. This allows the system to be much more compact than current stationary SPECT systems that image objects of the same size. We describe three possible designs, for full-body, brain and small-animal imaging, respectively, and test their feasibility using simulations. The system modeling method is validated against realistic Monte Carlo simulations, and then used in the evaluation of the systems' performances and reconstructions. The simulations show that the system is able to reconstruct objects occupying the predicted field of view (75% of the transaxial area of the bore) without sampling artifacts. In particular, we perform reconstructions from noisy projection data obtained for an activity and scanning time similar to standard protocols for the three applications, and the resulting images indicate the possibility of using the proposed systems in practice.
引用
收藏
页码:8791 / 8807
页数:17
相关论文
共 23 条
  • [1] Anger H.O., 1967, INSTRUMENTATION NUCL, V1, P485
  • [2] [Anonymous], 2013, PHD DISSERTATION
  • [3] Barrett H H, 1996, RADIOLOGICAL IMAGING
  • [4] Beekman FJ, 2005, J NUCL MED, V46, P1194
  • [5] Murine cardiac images obtained with focusing pinhole SPECT are barely influenced by extra-cardiac activity
    Branderhorst, Woutjan
    van der Have, Frans
    Vastenhouw, Brendan
    Viergever, Max A.
    Beekman, Freek J.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (03) : 717 - 732
  • [6] Quantification of diphosphonate uptake based on conventional bone scanning
    Brenner, W
    Bohuslavizki, KH
    Sieweke, N
    Tinnemeyer, S
    Clausen, M
    Henze, E
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1997, 24 (10) : 1284 - 1290
  • [7] Catafau AM, 2001, J NUCL MED, V42, P259
  • [8] Calibration of scintillation cameras and pinhole SPECT Imaging systems
    Chen, YC
    Furenlid, LR
    Wilson, DW
    Barrett, HH
    [J]. Small Animal SPECT Imaging, 2005, : 195 - 201
  • [9] Deprez K, 2013, J NUCL MED, V54, P2165
  • [10] Characterization of a SPECT pinhole collimator for optimal detector usage (the lofthole)
    Deprez, Karel
    Pato, Lara R. V.
    Vandenberghe, Stefaan
    Van Holen, Roel
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (04) : 859 - 885