Information content with low- vs. high-Tc SQUID arrays in MEG recordings: The case for high-TcSQUID-based MEG

被引:38
作者
Schneiderman, Justin F. [1 ,2 ,3 ]
机构
[1] MedTech West, Gothenburg, Sweden
[2] Sahlgrens Acad, Inst Neurosci & Physiol, Gothenburg, Sweden
[3] Univ Gothenburg, Gothenburg, Sweden
基金
瑞典研究理事会;
关键词
Channel capacity; Total information; High-T-c SQUID; MEG; SQUID-sensor arrays; Neuroimaging; MAGNETIC-FIELDS; MAGNETOENCEPHALOGRAPHY;
D O I
10.1016/j.jneumeth.2013.10.007
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: Magnetoencephalography (MEG) is a method of studying brain activity via recordings of the magnetic field generated by neural activity. Modern MEG systems employ an array of low critical-temperature superconducting quantum interference devices (low-T-c SQUIDs) that surround the head. The geometric distribution of these arrays is optimized by maximizing the information content available to the system in brain activity recordings according to Shannon's theory of noisy channel capacity. New method: Herein, we present a theoretical comparison of the performance of low- and high-T-c SQUID-based multichannel systems in recordings of brain activity. Results: We find a high-T-c SQUID magnetometer-based multichannel system is capable of extracting at least 40% more information than an equivalent low-T-c SQUID system. The results suggest more information can be extracted from high-T-c SQUID MEG recordings (despite higher sensor noise levels than their low-T-c counterparts) because of the closer proximity to neural sources in the brain. Comparison with existing methods: We have duplicated previous results in terms of total information of multichannel low-T-c SQUID arrays for MEG. High-T-c SQUID technology theoretically outperforms its conventional low-T-c counterpart in MEG recordings. Conclusions:A full-head high-T-c SQUID-based MEG system's potential for extraction of more information about neural activity can be used to, e.g., develop better diagnostic and monitoring techniques for brain disease and enhance our understanding of the working human brain. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:42 / 46
页数:5
相关论文
共 13 条
[1]   SAMPLING THEORY FOR NEUROMAGNETIC DETECTOR ARRAYS [J].
AHONEN, AI ;
HAMALAINEN, MS ;
ILMONIEMI, RJ ;
KAJOLA, MJ ;
KNUUTILA, JET ;
SIMOLA, JT ;
VILKMAN, VA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1993, 40 (09) :859-869
[2]  
Clarke J., 2004, The SQUID Handbook, V1
[3]   MAGNETOENCEPHALOGRAPHY - EVIDENCE OF MAGNETIC FIELDS PRODUCED BY ALPHA-RHYTHM CURRENTS [J].
COHEN, D .
SCIENCE, 1968, 161 (3843) :784-&
[4]   A New Generation of the HTS Multilayer DC-SQUID Magnetometers and Gradiometers [J].
Faley, M. I. ;
Poppe, U. ;
Urban, K. ;
Paulson, D. N. ;
Fagaly, R. L. .
7TH EUROPEAN CONFERENCE ON APPLIED SUPERCONDUCTIVITY (EUCAS'05), 2006, 43 :1199-1202
[5]   INTERPRETING MAGNETIC-FIELDS OF THE BRAIN - MINIMUM NORM ESTIMATES [J].
HAMALAINEN, MS ;
ILMONIEMI, RJ .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1994, 32 (01) :35-42
[6]  
Hansen P., 2010, MEG: An Introduction to Methods
[7]   Magnetoencephalography: From SQUIDs to neuroscience Neuroimage 20th Anniversary Special Edition [J].
Hari, Riitta ;
Salmelin, Riitta .
NEUROIMAGE, 2012, 61 (02) :386-396
[8]  
Kemppainen PK, 1990, ADV BIOMAGNETISM, P635
[9]   A 122-CHANNEL WHOLE-CORTEX SQUID SYSTEM FOR MEASURING THE BRAINS MAGNETIC-FIELDS [J].
KNUUTILA, JET ;
AHONEN, AI ;
HAMALAINEN, MS ;
KAJOLA, MJ ;
LAINE, PP ;
LOUNASMAA, OV ;
PARKKONEN, LT ;
SIMOLA, JTA ;
TESCHE, CD .
IEEE TRANSACTIONS ON MAGNETICS, 1993, 29 (06) :3315-3320
[10]  
Nenonen J, 2004, BIOMAG2004, V14, P630