Highly cross-linked versus conventional polyethylene inserts in total hip arthroplasty, a five-year Roentgen stereophotogrammetric analysis randomised controlled trial

被引:5
作者
van Loon, Justin [1 ,2 ]
Hoornenborg, Daniel [1 ]
Sierevelt, Inger [1 ]
Opdam, Kim T. M. [2 ]
Kerkhoffs, Gino M. M. J. [2 ]
Haverkamp, Daniel [1 ]
机构
[1] Xpert Orthoped Amsterdam Specialized Ctr Orthoped, Dept Orthopaed Surg, Laarderhoogtweg 12, NL-1101 EA Amsterdam, Netherlands
[2] Amsterdam Univ Med Ctr, Locat Acad Med Ctr, Dept Orthopaed Surg, NL-1105 AZ Amsterdam, Netherlands
关键词
Highly cross-linked polyethylene; Primary total hip arthroplasty; Polyethylene wear; Roentgen stereophotogrammetric analysis; MOLECULAR-WEIGHT POLYETHYLENE; FEMORAL-HEAD; WEAR-RATES; OSTEOLYSIS; REVISION; ORIENTATION; MACROPHAGES; ACCURACY; OUTCOMES; DEBRIS;
D O I
10.5312/wjo.v11.i10.442
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BACKGROUND Polyethylene (PE) particles produced by wear of the acetabular insert are thought to cause osteolysis and thereby aseptic loosening of the implant in total hip arthroplasty (THA). As highly cross-linked polyethylene (HXLPE) is presumed to give lower wear rates, in vivo studies are needed to confirm this. AIM To compare the wear of REXPOL, a HXPLE, with conventional PE within the first five years after implantation using Roentgen stereophotogrammetric analysis (RSA). METHODS Patients were randomised to receive either a HXLPE (REXPOL) or a conventional PE insert during primary THA. RSA images were obtained directly postoperative and after 6 wk, 12 wk, 6 mo, 12 mo, 24 mo and five years. Functional outcomes were assessed using the Hip Injury and Osteoarthritis Outcome Score and Harris Hip Score at baseline and five years after surgery. RESULTS The HXLPE (REXPOL) showed less wear in the latero-medial direction. Significant wear rates of conventional PE were seen in the latero-medial and center-proximal direction and in volume and corrected volume, whereas the REXPOL did not show these outcomes over time. Improvement from baseline in functional outcome did not significantly differ. CONCLUSION Total 3D wear is less in THAs inserted with a REXPOL inlay than a conventional PE inlay after five years. This study confirms, for the first, that the REXPOL HXLPE inlay is preferred to standard PE.
引用
收藏
页码:442 / 452
页数:11
相关论文
共 36 条
[1]  
Asaumi H, 1995, ACTA HORTIC, P111, DOI 10.17660/ActaHortic.1995.391.9
[2]  
Atienza Cesar Jr, 2008, J Surg Orthop Adv, V17, P27
[3]   Steady-state penetration rates of electron beam-irradiated, highly cross-linked polyethylene at an average 45-month follow-up [J].
Bragdon, Charles R. ;
Barrett, Susan ;
Martell, John M. ;
Greene, Meridith E. ;
Malchau, Henrik ;
Harris, William H. .
JOURNAL OF ARTHROPLASTY, 2006, 21 (07) :935-943
[4]   Experimental assessment of precision and accuracy of radio stereometric analysis for the determination of polyethylene wear in a total hip replacement model [J].
Bragdon, CR ;
Malchau, H ;
Yuan, XH ;
Perinchief, R ;
Kärrholm, J ;
Börlin, N ;
Estok, DM ;
Harris, WH .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2002, 20 (04) :688-695
[5]   The Relationship Between Polyethylene Wear and Periprosthetic Osteolysis in Total Hip Arthroplasty at 12 Years in a Randomized Controlled Trial Cohort [J].
Broomfield, John A. J. ;
Malak, Tamer T. ;
Thomas, Geraint E. R. ;
Palmer, Antony J. R. ;
Taylor, Adrian ;
Glyn-Jones, Sion .
JOURNAL OF ARTHROPLASTY, 2017, 32 (04) :1186-1191
[6]   Wear of highly crosslinked polyethylene acetabular components [J].
Callary, Stuart A. ;
Solomon, Lucian B. ;
Holubowycz, Oksana T. ;
Campbell, David G. ;
Munn, Zachary ;
Howie, Donald W. .
ACTA ORTHOPAEDICA, 2015, 86 (02) :159-168
[7]   Low Wear of a Second-generation Highly Crosslinked Polyethylene Liner: A 5-year Radiostereometric Analysis Study [J].
Callary, Stuart A. ;
Field, John R. ;
Campbell, David G. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2013, 471 (11) :3596-3600
[8]   Second-generation Highly Cross-linked X3™ Polyethylene Wear: A Preliminary Radiostereometric Analysis Study [J].
Campbell, David G. ;
Field, John R. ;
Callary, Stuart A. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (10) :2704-2709
[9]   Wear analysis of failed acetabular polyethylene - A Comparison of analytical methods [J].
Chuter, G. S. J. ;
Cloke, D. J. ;
Mahomed, A. ;
Partington, P. F. ;
Green, S. M. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2007, 89B (02) :273-279
[10]   Cross-Linked Polyethylene for Total Hip Arthroplasty Markedly Reduces Revision Surgery at 16 Years [J].
de Steiger, R. ;
Lorimer, M. ;
Graves, S. E. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2018, 100 (15) :1281-1288