Multispectral imaging of acute wound tissue oxygenation

被引:10
作者
Huong, Audrey [1 ]
Philimon, Sheena [1 ]
Ngu, Xavier [1 ]
机构
[1] Univ Tun Hussein Onn Malaysia, Fac Elect & Elect Engn, Dept Elect Engn, Batu Pahat 86400, Johor, Malaysia
关键词
Multispectral imaging; wound healing; transcutaneous blood oxygen saturation; extended modified Lambert-Beer;
D O I
10.1142/S1793545817500043
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
This paper investigates the appropriate range of values for the transcutaneous blood oxygen saturation (StO2) of granulating tissues and the surrounding tissue that can ensure timely wound recovery. This work has used a multispectral imaging system to collect wound images at wavelengths ranging between 520 nm and 600 nm with a resolution of 10 nm. As part of this research, a pilot study was conducted on three injured individuals with superficial wounds of different wound ages at different skin locations. The StO2 value predicted for the examined wounds using the Extended Modified Lambert-Beer model revealed a mean StO2 of 61 +/- 10.3% compared to 41.6 +/- 6.2% at the surrounding tissues, and 50.1 +/- 1.53% for control sites. These preliminary results contribute to the existing knowledge on the possible range and variation of wound bed StO2 that are to be used as indicators of the functioning of the vasomotion system and wound health. This study has concluded that a high StO2 of approximately 60% and a large fluctuation in this value should precede a good progression in wound healing.
引用
收藏
页数:8
相关论文
共 16 条
[1]  
Barnikol W. K., 2012, GMS GERMAN MED SCI, V10, P1
[2]   Use of a multi-spectral camera in the characterization of skin wounds [J].
Basiri, Ali ;
Nabili, Marjan ;
Mathews, Scott ;
Libin, Alex ;
Groah, Suzanne ;
Noordmans, Herke J. ;
Ramella-Roman, Jessica C. .
OPTICS EXPRESS, 2010, 18 (04) :3244-3257
[3]   A new method for on-line measurement of the volumetric oxygen uptake rate in membrane aerated animal cell cultures [J].
Ducommun, P ;
Ruffieux, PA ;
Furter, MP ;
Marison, I ;
von Stockar, U .
JOURNAL OF BIOTECHNOLOGY, 2000, 78 (02) :139-147
[4]  
Enoch S., 2008, Surgery, V26, P31, DOI [DOI 10.1016/J.MPSUR.2007.11.005, 10.1383/surg.23.2.37.60352, DOI 10.1383/SURG.23.2.37.60352]
[5]  
Flanagan M, 2000, J Wound Care, V9, P299
[6]  
Frieri M., 2016, WOUND MED, V13, P12, DOI DOI 10.1016/j.wndm.2016.02.004
[7]  
Huong A. K. C., 2015, INT C INN BIOM ENG L
[8]   The application of extended modified Lambert Beer model for measurement of blood carboxyhemoglobin and oxyhemoglobin saturation [J].
Huong, Audrey ;
Ngu, Xavier .
JOURNAL OF INNOVATIVE OPTICAL HEALTH SCIENCES, 2014, 7 (03)
[9]   IN SITU MONITORING OF MEAN BLOOD OXYGEN SATURATION USING EXTENDED MODIFIED LAMBERT BEER MODEL [J].
Huong, Audrey K. C. ;
Ngu, Xavier T. I. .
BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS, 2015, 27 (01)
[10]   Spatial frequency domain imaging of burn wounds in a preclinical model of graded burn severity [J].
John Quan Nguyen ;
Crouzet, Christian ;
Mai, Tuan ;
Riola, Kathleen ;
Uchitel, Daniel ;
Liaw, Lih-Huei ;
Bernal, Nicole ;
Ponticorvo, Adrien ;
Choi, Bernard ;
Durkin, Anthony J. .
JOURNAL OF BIOMEDICAL OPTICS, 2013, 18 (06)