Initial Experiments of a Needle-Holding Robot for Microwave Ablation Therapy

被引:0
作者
Deng Shuangcheng [1 ]
Jiang Lipei [1 ]
Cao Yingyu [1 ]
Ping, Liang [2 ]
He, Ren [2 ]
Yang, Wang [2 ]
Tong, Lu [2 ]
机构
[1] Beijing Inst Petrochem Technol, Optomechatron Equipment Technol Beijing Area, Major Lab, Beijing 102617, Peoples R China
[2] Peoples Liberat Army Gen Hosp, Dept Ultrasound, Beijing 100853, Peoples R China
来源
2008 10TH INTERNATIONAL CONFERENCE ON CONTROL AUTOMATION ROBOTICS & VISION: ICARV 2008, VOLS 1-4 | 2008年
关键词
medical robot; microwave ablation; motion tracking; robotic hand; damping force; RADIOFREQUENCY ABLATION; ULTRASOUND; MANAGEMENT;
D O I
10.1109/ICARCV.2008.4795587
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
A needle-holding robot for microwave ablation therapy is developed to free two hands of the surgeon, so that more effort can be concentrated on monitoring the ablation procedure, which in turn guarantees good tumor ablation effect The overall architecture of the robot is introduced first with the explanation of the mechanism of 3D motion tracking and how to minimize damping force for the robotic hand. Two experiments were conducted, one to quantify the force required for motion tracking, the other to assess the performance of motion tracking. The results of force-measuring experiment show that the force required for rotation and radial translation motion tracking are less than 15 grams, which indicates the high sensitivity of the holding robot. The results of in-vivo animal test performed on a swine show that the holding robot is accurate enough in tracking the 313 motion of the ablation needle, which allows for stable and precise holding of the needle compared to that of freehand holding.
引用
收藏
页码:605 / +
页数:2
相关论文
共 12 条
  • [1] Radiofrequency ablation in 447 complex unresectable liver tumors: Lessons learned
    Bleicher, RJ
    Allegra, DP
    Nora, DT
    Wood, TF
    Foshag, LJ
    Bilchik, AJ
    [J]. ANNALS OF SURGICAL ONCOLOGY, 2003, 10 (01) : 52 - 58
  • [2] Management of hepatic metastases
    Choti, MA
    Bulkley, GB
    [J]. LIVER TRANSPLANTATION AND SURGERY, 1999, 5 (01): : 65 - 80
  • [3] ULTRASOUND QUANTITATION OF RESPIRATORY ORGAN MOTION IN THE UPPER ABDOMEN
    DAVIES, SC
    HILL, AL
    HOLMES, RB
    HALLIWELL, M
    JACKSON, PC
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1994, 67 (803) : 1096 - 1102
  • [4] GOBBI DG, 2002, LNCS, V2489, P156
  • [5] HONG JS, 2002, LNCS, V2488, P9
  • [6] RESPIRATORY KINEMATICS OF THE UPPER ABDOMINAL ORGANS - A QUANTITATIVE STUDY
    KORIN, HW
    EHMAN, RL
    RIEDERER, SJ
    FELMLEE, JP
    GRIMM, RC
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1992, 23 (01) : 172 - 178
  • [7] NAKAKURA E, 2000, ADV ONC, V16, P12
  • [8] Nakakura EK, 2000, ONCOLOGY-NY, V14, P1085
  • [9] Salcudean SE, 1999, LECT NOTES COMPUT SC, V1679, P1062
  • [10] Accuracy and effectiveness of laparoscopic vs open hepatic radiofrequency ablation
    Scott, DJ
    Young, WN
    Watumull, LM
    Lindberg, G
    Fleming, JB
    Huth, JF
    Rege, RV
    Jeyarajah, DR
    Jones, DB
    [J]. SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2001, 15 (02): : 135 - 140