Effects of Small-Size Suspended Solids on the Emission of Escherichia coli from the Aeration Process of Wastewater Treatment

被引:13
作者
Lin, Tzu-Hsien [1 ,2 ]
Chiang, Chow-Feng [3 ]
Lin, Shaw-Tao [4 ]
Tsai, Ching-Tsan [5 ]
机构
[1] China Med Univ, Dept Dent Hyg, Taichung 40402, Taiwan
[2] China Med Univ, Dept Occupat Safety & Hlth, Taichung 40402, Taiwan
[3] China Med Univ, Dept Hlth Risk Management, Taichung 40402, Taiwan
[4] Providence Univ, Dept Appl Chem, Taichung 43301, Taiwan
[5] China Med Univ, Dept Publ Hlth, Taichung 40402, Taiwan
关键词
Bioaerosols; Suspended solids; Wastewater treatment plant; E; coli; TREATMENT PLANTS; BIOAEROSOL EMISSIONS; AIRBORNE BACTERIA; MICROORGANISMS; SLUDGE; PARTICLES; AEROSOLS; AIR; PERFORMANCE; IMPACTORS;
D O I
10.4209/aaqr.2015.04.0232
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The concentrations of bioaerosols near pretreatment facilities are often higher than those near activated-sludge aeration tanks in wastewater treatment plants (WWTP). The reason for this difference is not yet clear and the differences between the characteristics of suspended solids (SS) in these two processes might play a critical role. In this study, a lab-scale wastewater treatment system was tested with Escherichia coli (E. coli) in order to investigate the effects of the type and concentration of SS on the concentration and size distribution of emitted bioaerosols. Two types of SS, activated sludge from a hospital WWTP and kaolin clay, were selected to represent floc-type mixed-liquor SS (MLSS) and non-floc-type SS, respectively. An Andersen six-stage sampler was used to analyze the size distribution of the airborne E. coli aerosols. When the tested aeration rate was as low as 0.5 L min(-1), it was found that the presence of bioaerosols slightly decreased in air/water ratio (AWR, CFU m(-3) air/CFU 100 mL(-1) water) when the SS increased from 500 to 2000 mg L-1 for both floc and non-floc SS. However when the aeration rates went up to 5-15 L min(-1), the pattern of AWR vs. SS curve was different with an increase trend for non-floc SS and a decrease trend for floc SS, with an exception of increase trend for floc SS as the MLSS increased from 0 to 500 mg L-1. The major sizes of emitted bioaerosols ranged from 0.65 to 1.1 mu m. A peak was observed at an aerodynamic diameter greater than 7 mu m when the aeration rate was 15 L min(-1). In conclusion, floc-type activated sludge can inhibit the emission of E. coli from an aeration tank. In contrast, the non-floc-type small-size kaolin clay can enhance the emission of E. coli from the pretreatment process.
引用
收藏
页码:2208 / 2215
页数:8
相关论文
共 41 条
  • [1] NEW SAMPLER FOR THE COLLECTION, SIZING, AND ENUMERATION OF VIABLE AIRBORNE PARTICLES
    ANDERSEN, AA
    [J]. JOURNAL OF BACTERIOLOGY, 1958, 76 (05) : 471 - 484
  • [2] Evaluation of the environmental impact of microbial aerosols generated by wastewater treatment plants utilizing different aeration systems
    Brandi, G
    Sisti, M
    Amagliani, G
    [J]. JOURNAL OF APPLIED MICROBIOLOGY, 2000, 88 (05) : 845 - 852
  • [3] Characteristics of Microbial Aerosols Released from Chicken and Swine Feces
    Chien, Yeh-Chung
    Chen, Chiou-Jong
    Lin, Tzu-Hsien
    Chen, Shih-Hsun
    Chien, Yu-Ching
    [J]. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2011, 61 (08) : 882 - 889
  • [4] EFFECT OF AN ACTIVATED-SLUDGE WASTE-WATER TREATMENT-PLANT ON AMBIENT AIR DENSITIES OF AEROSOLS CONTAINING BACTERIA AND VIRUSES
    FANNIN, KF
    VANA, SC
    JAKUBOWSKI, W
    [J]. APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1985, 49 (05) : 1191 - 1196
  • [5] Changes at art activated sludge sewage treatment plant alter the numbers of airborne aerobic microorganisms
    Fernando, NL
    Fedorak, PM
    [J]. WATER RESEARCH, 2005, 39 (19) : 4597 - 4608
  • [6] Site-related airborne biological hazard and seasonal variations in two wastewater treatment plants
    Fracchia, L
    Pietronave, S
    Rinaldia, M
    Martinotti, MG
    [J]. WATER RESEARCH, 2006, 40 (10) : 1985 - 1994
  • [7] Characterization and Proinflammatory Response of Airborne Biological Particles from Wastewater Treatment Plants
    Gangamma, S.
    Patil, R. S.
    Mukherji, S.
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2011, 45 (08) : 3282 - 3287
  • [8] Goyer N, 2001, AIHAJ, V62, P330, DOI 10.1080/15298660108984635
  • [9] Reduction and characterization of bioaerosols in a wastewater treatment station via ventilation
    Guo, Xuesong
    Wu, Pianpian
    Ding, Wenjie
    Zhang, Weiyi
    Li, Lin
    [J]. JOURNAL OF ENVIRONMENTAL SCIENCES, 2014, 26 (08) : 1575 - 1583
  • [10] Airborne enteric coliphages and bacteria in sewage treatment plants
    Heinonen-Tanski, Helvi
    Reponen, Tiina
    Koivunen, Jari
    [J]. WATER RESEARCH, 2009, 43 (09) : 2558 - 2566