A new method to assess fetal head descent in labor with transperineal ultrasound

被引:224
作者
Barbera, A. F. [1 ]
Pombar, X. [4 ]
Perugino, G. [5 ]
Lezotte, D. C. [3 ]
Hobbins, J. C. [2 ]
机构
[1] Denver Hlth Med Ctr, Dept Obstet & Gynecol, Denver, CO 80204 USA
[2] Univ Colorado, Sch Med, Dept Obstet & Gynecol, Aurora, CO USA
[3] Univ Colorado, Sch Med, Dept Prevent Med & Biometr, Aurora, CO USA
[4] Rush Univ, Dept Obstet & Gynecol, Chicago, IL 60612 USA
[5] IRCCS Mangiagalli, Dept Obstet & Gynecol, Milan, Italy
关键词
fetal head station; labor; transperineal ultrasound; ENGAGEMENT; SONOGRAPHY;
D O I
10.1002/uog.6329
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives To assess the feasibility and reproducibility of measuring fetal head station and descent during labor using transperineal ultrasound (TPU) imaging, to compare the evaluation of fetal station through digital examinations with concurrent TPU assessments, and to assess its utility in distinguishing patients whose pregnancy will result in spontaneous vaginal delivery front those who will require operative vaginal delivery or Cesarean section for failure to progress. Methods TPU and digital examinations were performed in 88 term laboring patients with a singleton fetus in cephalic presentation. Using TPU imaging, head descent was quantified by measuring the angle between the long axis of the pubic symphysis and a line extending from its most inferior Portion tangentially to the fetal skull. Intraobserver and interobserver variability were calculated using variance component analysis. TPU imaging was used to measure the angle of bead descent during the second stage of labor in 23 of the women. Results Analysis of replicated measurements on 75 subjects, by the same observer at approximately the same time, yielded an average SD (intraobserver variability) of approximately 2.9 degrees for the measurement of angle of bead descent on TPU examination. A separate variance component analysis on a subset of 15 assessments for which measurements were repeated by a second observer, with two to four replicate measurements obtained by each, yielded an interobserver error estimate of 1.24 degrees. A significant linear association was found between clinical digital assessments and measurement of angle of bead descent by TPU examination (P < 0.001). An angle of at least 120 degrees measured during the second stage of labor was always associated with subsequent spontaneous vaginal delivery. In six pregnancies ending in Cesarean section the mean angle of descent measured at last TPU examination was only 108 degrees. Conclusions The angle of bead descent measured by TPU imaging provides an objective, accurate and reproducible means for assessing descent of the fetal bead during labor. Copyright (c) 2009 ISUOG. Published by John Wiley & Sons, Ltd.
引用
收藏
页码:313 / 319
页数:7
相关论文
共 16 条
  • [1] Akmal S, 2002, J Matern Fetal Neonatal Med, V12, P172, DOI 10.1080/713605646
  • [2] [Anonymous], 2007, NATL VITAL STAT REP
  • [3] CRICHTON D, 1974, S AFR MED J, V48, P784
  • [4] Cunningham FG, 2005, WILLIAMS OBSTET, V22nd, P409
  • [5] Measuring engagement of the fetal head: validity and reproducibility of a new ultrasound technique
    Dietz, HP
    Lanzarone, V
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2005, 25 (02) : 165 - 168
  • [6] Ultrasound assessment of fetal head-perineum distance before induction of labor
    Eggebo, T. M.
    Heien, C.
    Okland, I.
    Gjessing, L. K.
    Romundstad, P.
    Salvesen, K. A.
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2008, 32 (02) : 199 - 204
  • [7] Intrapartum translabial ultrasound (ITU):: sonographic landmarks and correlation with successful vacuum extraction
    Henrich, W.
    Dudenhausen, J.
    Fuchs, I.
    Kaemena, A.
    Tutschek, B.
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2006, 28 (06) : 753 - 760
  • [8] A COMPARISON OF ABDOMINAL AND VAGINAL EXAMINATIONS FOR THE DIAGNOSIS OF ENGAGEMENT OF THE FETAL HEAD
    KNIGHT, D
    NEWNHAM, JP
    MCKENNA, M
    EVANS, S
    [J]. AUSTRALIAN & NEW ZEALAND JOURNAL OF OBSTETRICS & GYNAECOLOGY, 1993, 33 (02) : 154 - 158
  • [9] Indications for cesarean deliveries in Norway
    Kolås, T
    Hofoss, D
    Daltveit, AK
    Nilsen, ST
    Henriksen, T
    Häger, R
    Ingemarsson, I
    Oian, P
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2003, 188 (04) : 864 - 870
  • [10] MEASURING HEIGHT OF A CEPHALIC PRESENTATION - OBJECTIVE ASSESSMENT OF STATION
    LEWIN, D
    SADOUL, G
    BEURET, T
    [J]. EUROPEAN JOURNAL OF OBSTETRICS GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 1977, 7 (06): : 369 - 372