Improved mechanical reliability of the HeartMate XVE left ventricular assist system

被引:42
作者
Pagani, Francis D.
Long, James W.
Dembitsky, Walter P.
Joyce, Lyle D.
Miller, Leslie W.
机构
[1] Univ Michigan Hlth Syst, Sect Cardiac Surg, Taubman Ctr 2124, Ann Arbor, MI 48109 USA
[2] Univ Utah, Sch Med, Utah Artificial Heart Program, Salt Lake City, UT USA
[3] LDS Hosp, Salt Lake City, UT USA
[4] Sharp Mem Hosp & Rehabil Ctr, Div Cardiovasc Surg, San Diego, CA 90034 USA
[5] Univ Minnesota, Div Cardiothorac Surg, Minneapolis, MN USA
[6] Univ Minnesota, Div Cardiovasc, Minneapolis, MN 55455 USA
关键词
D O I
10.1016/j.athoracsur.2006.04.057
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. The HeartMate XVE left ventricular assist device is a valuable treatment option for patients with end-stage heart failure. During the past several years, the XVE has undergone a series of design enhancements to improve reliability. We compared the reliability of the two most recent design iterations of the XVE pump (stitch modification to the inflow valve assembly and new inflow valve housing redesign) to the earlier VE version. Methods. A retrospective evaluation of device reliability was performed for 268 devices implanted in 245 patients (VE: n = 167 devices, 147 patients, implant dates October 16, 1998, to December 19, 2003; XVE: n = 101 devices, 98 patients, implant dates August 1, 2002, to April 14, 2004). Results. Median duration of device support for the VE and XVE was 159 days (range, 0 to 1,206 days) and 229 days (range, 0 to 693 days), respectively (p = 0.495). Significantly fewer major device malfunctions occurred within the XVE group as compared with the VE group (6 versus 36, respectively; p = 0.0003). The number of major device malfunctions per patient-year of support for inflow valve dysfunction, bearing wear, and other failures for the VE and XVE were 0.2 versus 0.04 (p = 0.006), 0.16 versus 0.01 (p = 0.005), and 0.06 versus 0.04 (p = 1.000), respectively. The freedom from major device malfunction at 1 year was 76% +/- 6% for the VE and 97% +/- 2% for the XVE device (p < 0.001). The freedom from death as a result of major device malfunction at 1 year was 97% +/- 2% for the VE and 98% +/- 2% for the XVE (p = 0.698). Conclusions. Design enhancements to the HeartMate XVE have significantly reduced the incidence of major device malfunctions compared with the earlier VE model because of a reduction in failure modes from bearing wear and inlet valve dysfunction. Further follow-up is necessary to establish the long-term durability of the most recent XVE pump version.
引用
收藏
页码:1413 / 1419
页数:8
相关论文
共 15 条
[1]  
*AM HEART ASS, 2003, HEART DIS STROK STAT
[2]   Left ventricular assist device performance with long-term circulatory support: Lessons from the REMATCH trial [J].
Dembitsky, WP ;
Tector, AJ ;
Park, S ;
Moskowitz, AJ ;
Gelijns, AC ;
Ronan, NS ;
Piccione, W ;
Holman, WL ;
Furukawa, S ;
Frazier, OH ;
Weinberg, AD ;
Heatley, G ;
Poirier, VL ;
Damme, L ;
Long, JW .
ANNALS OF THORACIC SURGERY, 2004, 78 (06) :2123-2129
[3]   HeartMateo® VE LVAS design enhancements and its impact on device reliability [J].
Dowling, RD ;
Park, SJ ;
Pagani, FD ;
Tector, AJ ;
Naka, Y ;
Icenogle, TB ;
Poirier, VL ;
Frazier, OH .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2004, 25 (06) :958-963
[4]  
Frazier OH, 1998, TEX HEART I J, V25, P265
[5]   IMPROVED MORTALITY AND REHABILITATION OF TRANSPLANT CANDIDATES TREATED WITH A LONG-TERM IMPLANTABLE LEFT-VENTRICULAR ASSIST SYSTEM [J].
FRAZIER, OH ;
ROSE, EA ;
MCCARTHY, P ;
BURTON, NA ;
TECTOR, A ;
LEVIN, H ;
KAYNE, HL ;
POIRIER, VL ;
DASSE, KA .
ANNALS OF SURGERY, 1995, 222 (03) :327-338
[6]   The Registry of the International Society for Heart and Lung Transplantation: Seventeenth official report - 2000 [J].
Hosenpud, JD ;
Bennett, LE ;
Keck, BM ;
Boucek, MM ;
Novick, RJ .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2000, 19 (10) :909-931
[7]  
Long James W, 2005, Congest Heart Fail, V11, P133, DOI 10.1111/j.1527-5299.2005.04540.x
[8]   Advanced mechanical circulatory support with the HeartMate left ventricular assist device in the year 2000 [J].
Long, JW .
ANNALS OF THORACIC SURGERY, 2001, 71 (03) :S176-S182
[9]  
Pagani F. D., 2003, Journal of Heart and Lung Transplantation, V22, pS204, DOI 10.1016/S1053-2498(02)01095-1
[10]   Improved mechanical reliability of the HeartMate XVE left ventricular assist system [J].
Pagani, Francis D. ;
Long, James W. ;
Dembitsky, Walter P. ;
Joyce, Lyle D. ;
Miller, Leslie W. .
ANNALS OF THORACIC SURGERY, 2006, 82 (04) :1413-1419