An automated insertion tool for cochlear implants with integrated force sensing capability

被引:26
|
作者
Kobler, Jan-Philipp [1 ]
Beckmann, Daniel [1 ]
Rau, Thomas S. [2 ]
Majdani, Omid [2 ]
Ortmaier, Tobias [1 ]
机构
[1] Leibniz Univ Hannover, Inst Mechatron Syst, D-30167 Hannover, Germany
[2] Hannover Med Sch, D-30625 Hannover, Germany
关键词
Cochlear implants; Automated insertion tool; Surgical robotics; ELECTROACOUSTIC STIMULATION; CLINICAL VALIDATION; ELECTRODE INSERTION; DESIGN; ROBOT; ADVANCE; SURGEON;
D O I
10.1007/s11548-013-0936-1
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Minimally invasive cochlear implantation and residual hearing preservation require both the surgical approach to the cochlea as well as the implant insertion to be performed in an atraumatic fashion. Considering the geometric limitations of this approach, specialized instrumentation is required to insert the electrode while preserving intracochlear membranes carrying the sensory hair cells. An automated insertion tool for cochlear implants, which is capable of sensing insertion forces with a theoretical resolution of , is presented. In contrast to previous designs, the custom force sensor is integrated in the insertion mechanism. Moreover, a test bench for insertion studies under constant and reproducible boundary conditions is proposed. It is used to experimentally validate the force sensing insertion tool, which is achieved by comparing the acquired forces to a ground truth measurement. The results of insertion studies on both an acrylic cochlear phantom and temporal bone specimen are given and discussed. Results reveal that friction, occurring between the electrode carrier and the inside of the insertion tool guide tube, is likely to affect the force output of the proposed sensor. An appropriate method to compensate for these disturbances is presented and experimentally validated. Using the proposed approach to friction identification, a mean accuracy of is observed. The force information provided by the proposed, automated insertion tool can be used to detect complications during electrode insertion. However, in order to obtain accurate results, an identification of frictional forces prior to insertion is mandatory. The insertion tool is capable of automatically executing the appropriate trajectories.
引用
收藏
页码:481 / 494
页数:14
相关论文
共 50 条
  • [21] A New Manual Insertion Tool for Minimally Invasive, Image-Guided Cochlear Implant Surgery
    Riojas, Katherine E.
    Narasimhan, Narendran
    Morrel, William G.
    Mitchell, Jason
    Bruns, Trevor
    Webster, Robert J., III
    Labadie, Robert F.
    MEDICAL IMAGING 2019: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2019, 10951
  • [22] Polymeric fiber sensors for insertion forces and trajectory determination of cochlear implants in hearing preservation
    Gunawardena, Dinusha Serandi
    Cui, Jingxian
    Cheng, Xin
    Vadivelu, Arvind N.
    Mohammadi, Alireza
    Edbert, Geraldi
    Liu, Zhengyong
    Chen, Bernard
    Oetomo, Denny
    O'Leary, Stephen
    Tam, Hwa-Yaw
    BIOSENSORS & BIOELECTRONICS, 2023, 222
  • [23] 6-DOF Force Sensing for the Master Tool Manipulator of the da Vinci Surgical System
    Black, David G.
    Hosseinabadi, Amir H. Hadi
    Salcudean, Septimiu E.
    IEEE ROBOTICS AND AUTOMATION LETTERS, 2020, 5 (02) : 2264 - 2271
  • [24] A Manually Operated, Advance Off-Stylet Insertion Tool for Minimally Invasive Cochlear Implantation Surgery
    Kratchman, Louis B.
    Schurzig, Daniel
    McRackan, Theodore R.
    Balachandran, Ramya
    Noble, Jack H.
    Webster, Robert J., III
    Labadie, Robert F.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2012, 59 (10) : 2792 - 2800
  • [25] A Redundant Parallel Continuum Manipulator With Stiffness-Varying and Force-Sensing Capability
    Tang, Shujie
    Liang, Zhenkun
    Zhang, Zhuang
    Duan, Xuyang
    Wang, Hao
    Chen, Genliang
    IEEE TRANSACTIONS ON AUTOMATION SCIENCE AND ENGINEERING, 2025, 22 : 3635 - 3647
  • [26] Bilateral cochlear implants with large asymmetries in electrode insertion depth: implications for the study of auditory plasticity
    Svirsky, Mario A.
    Fitzgerald, Matthew B.
    Sagi, Elad
    Glassman, E. Katelyn
    ACTA OTO-LARYNGOLOGICA, 2015, 135 (04) : 354 - 363
  • [27] A SIMPLE MANUAL ROLLER WHEEL INSERTION TOOL FOR ELECTRODE ARRAY INSERTION IN MINIMALLY INVASIVE COCHLEAR IMPLANT SURGERY
    Narasimhan, Narendran
    Riojas, Katherine E.
    Bruns, Trevor L.
    Mitchell, Jason E.
    Webster, Robert J., III
    Labadie, Robert F.
    2019 DESIGN OF MEDICAL DEVICES CONFERENCE, 2019,
  • [28] Integrated use of volume conduction and neural models to simulate the response to cochlear implants
    Frijns, JHM
    Briaire, JJ
    Schoonhoven, R
    SIMULATION PRACTICE AND THEORY, 2000, 8 (1-2): : 75 - 97
  • [29] The Relationship Between Insertion Angles, Default Frequency Allocations, and Spiral Ganglion Place Pitch in Cochlear Implants
    Landsberger, David M.
    Svrakic, Maja
    Roland, J. Thomas
    Svirsky, Mario
    EAR AND HEARING, 2015, 36 (05) : E207 - E213
  • [30] An automated A-value measurement tool for accurate cochlear duct length estimation
    John E. Iyaniwura
    Mai Elfarnawany
    Hanif M. Ladak
    Sumit K. Agrawal
    Journal of Otolaryngology - Head & Neck Surgery, 47