Ultrasound-Energy Consumption During Phases of Phacoemulsification of Nuclear Cataracts Using Femtosecond Laser: A Comparative Study

被引:3
作者
Assaf, Ahmed H. [1 ,2 ]
Aziz, Bassem F. [1 ,2 ]
机构
[1] Ain Shams Univ, Fac Med, Ophthalmol Dept, Cairo, Egypt
[2] Al Watany Eye Hosp, Cairo, Egypt
来源
CLINICAL OPHTHALMOLOGY | 2020年 / 14卷
关键词
phacoemulsification; femtosecond laser; FLACS; cataract surgery; LENS FRAGMENTATION; SURGERY; TIME;
D O I
10.2147/OPTH.S257813
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare ultrasound (US) energy utilized in different phases of nuclear cataract removal in femtosecond laser-assisted cataract surgery (FLACS) with conventional phacoemulsification surgery (CPS) in relation to different nuclear densities. Methods: A prospective nonrandomized comparative study was conducted at AM Shams University and Al Watany Eye Hospital, Cairo, Egypt on 250 eyes with senile nuclear cataracts (NCs) of different nuclear densities (1-6). Eyes were divided into two groups - FLACS and CPS - and each group was subdivided according to cataract density into subgroups A (NC 1-2), B (NC 3-4) and C (NC 5-6). sextant-softened fragmentation patterns were assessed in the FLACS group and the quick-chop technique used in the CPS group. US energy required for nucleus cracking (EFX split) and for quadrant removal (EFX quadrant) was recorded. Results: Total eyes included in the FLACS and CPS groups were 117 and 133, respectively. No significant differences between the groups for EFX quadrant and EFX split groups were observed (P=0.18 and P=0.49, respectively). For subgroup A, no significant difference was found between FLACS and CPS on EFX split (P=0.08) and EFX quadrant (P=0.49). For subgroup B, significantly lower values of EFX split (P=0.0001) and EFX quadrant (P<0.0001) were obtained with FLACS than CPS. For subgroup C, no significant difference was found for EFX split (P=0.86), however, EFX quadrant was significantly lower in the FLACS group (P=0.05). Conclusion: FLACS lowers US energy utilized during quadrant removal at different nuclear densities, with highest significance in medium-density nuclear cataracts. Nucleus cracking by femtosecond laser is less effective in very hard cataracts. However, femtosecond-laser softening of hard nuclei is capable of of US-energy reduction during quadrant removal.
引用
收藏
页码:2829 / 2835
页数:7
相关论文
共 20 条
  • [1] Femtosecond laser-assisted cataract surgery compared with conventional cataract surgery
    Abell, Robin G.
    Kerr, Nathan M.
    Vote, Brendan J.
    [J]. CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2013, 41 (05) : 455 - 462
  • [2] Surgeon volumes and selected patient outcomes in cataract surgery - A population-based analysis
    Bell, Chaim M.
    Hatch, Wendy V.
    Cernat, Geta
    Urbach, David R.
    [J]. OPHTHALMOLOGY, 2007, 114 (03) : 405 - 410
  • [3] Visual and Refractive Outcomes in Manual versus Femtosecond Laser-Assisted Cataract Surgery A Single-Center Retrospective Cohort Analysis of 1838 Eyes
    Berk, Thomas A.
    Schlenker, Matthew B.
    Campos-Moller, Xavier
    Pereira, Austin M.
    Ahmed, Iqbal Ike K.
    [J]. OPHTHALMOLOGY, 2018, 125 (08) : 1172 - 1180
  • [4] Efficacy and safety of femtosecond laser-assisted cataract surgery versus conventional phacoemulsification for cataract: a meta-analysis of randomized controlled trials
    Chen, Xiaoyun
    Xiao, Wei
    Ye, Shaobi
    Chen, Weirong
    Liu, Yizhi
    [J]. SCIENTIFIC REPORTS, 2015, 5
  • [5] Comparison of visual recovery and refractive stability between femtosecond laser-assisted cataract surgery and standard phacoemulsification: Six-month follow-up
    Conrad-Hengerer, Ina
    Al Sheikh, Mayss
    Hengerer, Fritz H.
    Schultz, Tim
    Dick, H. Burkhard
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (07) : 1356 - 1364
  • [6] Effect of Femtosecond Laser Fragmentation on Effective Phacoemulsification Time in Cataract Surgery
    Conrad-Hengerer, Ina
    Hengerer, Fritz H.
    Schultz, Tim
    Dick, H. Burkhard
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2012, 28 (12) : 879 - +
  • [7] Effect of femtosecond laser fragmentation of the nucleus with different softening grid sizes on effective phaco time in cataract surgery
    Conrad-Hengerer, Ina
    Hengerer, Fritz H.
    Schultz, Tim
    Dick, H. Burkhard
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (11) : 1888 - 1894
  • [8] Translenticular hydrodissection, lens fragmentation, and influence on ultrasound power in femtosecond laser-assisted cataract surgery and refractive lens exchange
    Daya, Sheraz M.
    Nanavaty, Mayank A.
    Espinosa-Lagana, Marcela M.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (01) : 37 - 43
  • [9] Incidence of cataract surgery from 1980 through 2004: 25-year population-based study
    Erie, Jay C.
    Baratz, Keith H.
    Hodge, David O.
    Schleck, Cathy D.
    Burke, James P.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (07) : 1273 - 1277
  • [10] Femtosecond laser-assisted cataract surgery
    He, Lingmin
    Sheehy, Katrina
    Culbertson, William
    [J]. CURRENT OPINION IN OPHTHALMOLOGY, 2011, 22 (01) : 43 - 52