Effect of fiber structure on dialysate flow profile and hollow-fiber hemodialyzer reliability: CT perfusion study

被引:11
作者
Kim, J. C. [2 ]
Kim, J. H. [2 ]
Kim, H. -C. [3 ]
Kang, E. [4 ]
Kim, K. G. [5 ]
Kim, H. C. [1 ,6 ]
Min, B. G. [1 ,6 ,7 ]
Ronco, C. [8 ]
机构
[1] Seoul Natl Univ, Coll Med, Dept Biomed Engn, Seoul 110744, South Korea
[2] Seoul Natl Univ, Interdisciplinary Program Bioengn Major, Seoul 110744, South Korea
[3] Seoul Natl Univ Hosp, Dept Radiol, Seoul 110744, South Korea
[4] Chung Ang Univ Hosp, Dept Internal Med, Seoul, South Korea
[5] Natl Canc Ctr, Dept Biomed Engn, Div Basic & Appl Sci, Goyang, South Korea
[6] Seoul Natl Univ, Med Res Ctr, Inst Med & Biol Engn, Seoul 110744, South Korea
[7] Cheju Natl Univ, Dept Vet Med, Cheju, South Korea
[8] IRRIV, St Bortolo Hosp, Dept Nephrol, Vicenza, Italy
关键词
Artificial kidney; Dialysate flow; Perfusion computed tomography; Fiber structure; Dialysate channeling; Reliability; Dialysis adequacy;
D O I
10.1177/039139880803101104
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Uniform dialysate? distributions in hollow-fiber hemodialyzers facilitate effective solute removal, and the fiber structure inside hemodialyzers plays a significant role in determining dialysate flow distribution and dialysis efficiency. The authors analyzed the effects of undulated fibers on dialysate flow profiles and hemodialyzer reliability using a perfusion CT technique. Method: Using a multi-detector row CT unit, perfusion studies were performed on two different types of hemodialyzers: (A) straight fiber configuration; (B) undulated fiber configuration (wavy-shaped fibers). Deconvolution theory was used for image processing to derive dialysate flows, dialysate volumes, and mean transit time distributions. Three-dimensional perfusion maps for the two types of hemodialyzers were reconstructed using high resolution images and these parameters were compared at hemodialyzer midsections. Results: Dialysate maldistributions were observed in both types of hemodialyzer However, dialysate flow distributions were more uniform in the undulated-fiber hemodialyzer, whereas more complex flow distributions developed in straight-fiber hemodialyzer Reliability as determined using intraclass correlation coefficients was markedly higher for the hemodialyzer containing undulated fiber (0.968 vs. 0.496 for type A and type B, respectively). Conclusions: The undulated-fiber type was found to have more uniform, consistent dialysate flow profiles. It is believed that this type of hemodialyzer will be found helpful for measurement and prescription of the delivered hemodialysis dose due to its better consistency. (Int J Artif Organs 2008; 31: 944-50)
引用
收藏
页码:944 / 950
页数:7
相关论文
共 18 条
[1]  
Cenic A, 2000, AM J NEURORADIOL, V21, P462
[2]   Clinical evaluation of a new high efficiency hemodialyzer:: Polysynthane™ [J].
Clark, WR ;
Shinaberger, JH .
ASAIO JOURNAL, 2000, 46 (03) :288-292
[3]   Combining SPECT medical imaging and computational fluid dynamics for analyzing blood and dialysate flow in hemodialyzers [J].
Eloot, S ;
D'asseler, Y ;
De Bondt, P ;
Verdonck, P .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2005, 28 (07) :739-749
[4]   Differential receptor targeting of liver cells using 99mTc-neoglycosylated human serum albumins [J].
Kim, Sungeun ;
Jeong, Jae Min ;
Hong, Mee Kyung ;
Jang, Ja-June ;
Lee, Jaetae ;
Lee, Dong Soo ;
Chung, June-Key ;
Lee, Myung Chul .
ARCHIVES OF PHARMACAL RESEARCH, 2008, 31 (01) :60-66
[5]  
Kinney R, 2006, AM J KIDNEY DIS S, V48, pS13
[6]   Hollow fiber shape alters solute clearances in high flux hemodialyzers [J].
Leypoldt, JK ;
Cheung, AK ;
Chirananthavat, T ;
Gilson, JF ;
Kamerath, CD ;
Deeter, RB .
ASAIO JOURNAL, 2003, 49 (01) :81-87
[7]  
LEYPOLDT JK, 2004, REPLACEMENT RENAL FU, P95
[8]   Sources of non-ideal flow distribution and their effect on the performance of hollow fiber gas separation modules [J].
Lipscomb, GG ;
Sonalkar, S .
SEPARATION AND PURIFICATION REVIEWS, 2004, 33 (01) :41-76
[9]   Effect of spacer yarns on the dialysate flow distribution of hemodialyzers: A magnetic resonance imaging study [J].
Poh, CK ;
Hardy, PA ;
Liao, ZJ ;
Huang, ZP ;
Clark, WR ;
Gao, DY .
ASAIO JOURNAL, 2003, 49 (04) :440-448
[10]   Dialysate flow distribution in hollow fiber hemodialyzers with different dialysate pathway configurations [J].
Ronco, C ;
Brendolan, A ;
Crepaldi, C ;
Rodighiero, M ;
Everard, P ;
Ballestri, M ;
Cappelli, G ;
Spittle, M ;
La Greca, G .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2000, 23 (09) :601-609