The pulmonary capillary wedge pressure accurately reflects both normal and elevated left atrial pressure

被引:14
作者
Nagy, Aniko I. [1 ]
Venkateshvaran, Ashwin [2 ,3 ]
Dash, Pravat Kumar [3 ]
Barooah, Banajit [3 ]
Merkely, Bela [1 ]
Winter, Reidar [2 ,4 ]
Manouras, Aristomenis [2 ,4 ]
机构
[1] Semmelweis Univ, Heart & Vasc Ctr, H-1122 Budapest, Hungary
[2] Royal Inst Technol, Sch Technol & Hlth, Stockholm, Sweden
[3] Sri Sathya Sai Inst Higher Med Sci, Bangalore, Karnataka, India
[4] Karolinska Univ Hosp, Dept Cardiol, Stockholm, Sweden
关键词
MITRAL-STENOSIS;
D O I
10.1016/j.ahj.2014.01.012
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Pulmonary capillary wedge pressure (PCWP) is routinely used as an indirect measure of the left atrial pressure (LAP), although the accuracy of this estimate, especially under pathological hemodynamic conditions, remains controversial. Objectives The aim of this prospective study was to investigate the reliability of PCWP for the evaluation of LAP under different hemodynamic conditions. Methods Simultaneous left and right heart catheterization data of 117 patients with pure mitral stenosis, obtained before and immediately after percutaneous mitral comissurotomy, were analyzed. Results A strong correlation and agreement between PCWP and LAP measurements was demonstrated (correlation coefficient = 0.97, mean bias +/- CI, 0.3 +/- -3.7 to 4.2 mm Hg). Comparison of measurements performed within a 5-minute interval and those performed simultaneously revealed that simultaneous pressure acquisition yielded better agreement between the 2 methods (bias +/- CI, 1.82 +/- 1.98 mm Hg). In contrast to previous observations, the discrepancy between the 2 measures did not increase with elevated PCWP. Multiple regression analysis failed to identify hemodynamic confounders of the discrepancy between the 2 pressures. The ability of PCWP to distinguish between normal and elevated LAP (cutoff set at 12 and 15 mm Hg, respectively), as tested by receiver operating characteristics analysis, demonstrated a remarkably high diagnostic accuracy (area under the curve: 0.989 and 0.996, respectively). Conclusions Although the described limits of agreement may not allow the interchangeability of PCWP and LAP, especially at lower pressure ranges, our data support the clinical use of PCWP as a robust and accurate estimate of LAP.
引用
收藏
页码:876 / 883
页数:8
相关论文
共 23 条
[2]   INTERRELATIONS OF PULMONARY ARTERIAL, CAPILLARY AND LEFT ATRIAL PRESSURES UNDER EXPERIMENTAL CONDITIONS [J].
ANKENEY, JL .
AMERICAN JOURNAL OF PHYSIOLOGY, 1952, 169 (01) :40-49
[3]  
BERNSTEIN WH, 1960, BRIT HEART J, V22, P37
[4]   FORWARD AND BACKWARD TRANSMISSION OF PRESSURE WAVES IN PULMONARY VASCULAR BED OF DOG [J].
CARO, CG ;
BERGEL, DH ;
SEED, WA .
CIRCULATION RESEARCH, 1967, 20 (02) :185-&
[5]  
Cohen J., 2003, APPL MULTIPLE REGRES, VThird ed., DOI 10.4324/9780203774441
[6]  
CONNOLLY DC, 1953, P STAFF M MAYO CLIN, V28, P72
[7]  
CONNOLLY DC, 1954, CIRC RES, V2, P434
[8]  
EPPS RG, 1953, BRIT HEART J, V15, P298
[9]   AN EVALUATION OF WEDGE PRESSURES IN DOGS UNDER CONDITIONS OF NORMAL AND ELEVATED PULMONARY VASCULAR PRESSURES [J].
HADDY, FJ ;
ALDEN, JF ;
FERRIN, AL ;
HANNON, DW ;
ADAMS, WL ;
BARONOFSKY, ID .
CIRCULATION RESEARCH, 1953, 1 (02) :157-161
[10]   THE MEANING AND USE OF THE AREA UNDER A RECEIVER OPERATING CHARACTERISTIC (ROC) CURVE [J].
HANLEY, JA ;
MCNEIL, BJ .
RADIOLOGY, 1982, 143 (01) :29-36