Correction for non-spectroscopic matrix effects in inductively coupled plasma-mass spectrometry by common analyte internal standardization

被引:33
作者
Al-Ammar, AS [1 ]
Gupta, RK [1 ]
Barnes, RM [1 ]
机构
[1] Univ Massachusetts, Dept Chem, Lederle Grad Res Towers, Amherst, MA 01003 USA
关键词
matrix effect correction; inductively coupled plasma-mass spectrometry; Common Analyte Internal Standardization (CAIS);
D O I
10.1016/S0584-8547(99)00129-9
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The Common Analyte Internal Standardization (CATS) chemometric technique is extended to correct for non-spectroscopic matrix effects in inductively coupled plasma-mass spectrometry (ICP-MS). The approach is based on using an internal reference element to correct for the matrix effect. Unlike the conventional internal reference method, the CAIS technique allows for the analyte to behave differently from the internal reference under the influence of the matrix. With the CATS technique a single internal reference element is sufficient to correct for all the analytes. Experimental tests with 13 analytes in four different matrices using different ICP-MS instruments demonstrate that the CAIS is efficient and general for matrix effect correction. Not only is the corrected concentration more accurate, but the precision is significantly better. The capability of CAIS to correct for the effect of a mixture of two matrices was also established experimentally, and 20-30% matrix suppression was eliminated. Furthermore, the developed technique was used as a simple diagnostic quality assurance procedure to evaluate the performance of the mass spectrometer. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1849 / 1860
页数:12
相关论文
共 14 条
[1]  
Al-Ammar AS, 1998, ATOM SPECTROSC, V19, P18
[2]   Correction for non-spectroscopic matrix effects in inductively coupled plasma-atomic emission spectroscopy by internal standardization using spectral lines of the same analyte [J].
Al-Ammar, AS ;
Barnes, RM .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1998, 53 (11) :1583-1593
[3]   STUDY OF THE EFFECTS OF CONCOMITANT ELEMENTS IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
BEAUCHEMIN, D ;
MCLAREN, JW ;
BERMAN, SS .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1987, 42 (03) :467-490
[4]   Space charge evaluation in a plasma-source mass spectrograph [J].
Burgoyne, TW ;
Hieftje, GM ;
Hites, RA .
ANALYTICAL CHEMISTRY, 1997, 69 (03) :485-489
[5]   NONSPECTROSCOPIC INTERELEMENT INTERFERENCES IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
GILLSON, GR ;
DOUGLAS, DJ ;
FULFORD, JE ;
HALLIGAN, KW ;
TANNER, SD .
ANALYTICAL CHEMISTRY, 1988, 60 (14) :1472-1474
[8]  
GREGOIRE DC, 1989, PROG ANAL SPECTROSC, V12, P433
[9]   DETERMINATION OF BORON IN FRESH AND SALINE WATERS BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
GREGOIRE, DC .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1990, 5 (07) :623-626
[10]   NON-SPECTROSCOPIC MATRIX INTERFERENCES IN INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY [J].
KIM, YS ;
KAWAGUCHI, H ;
TANAKA, T ;
MIZUIKE, A .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1990, 45 (03) :333-339