Energy response calibration of photon-counting detectors using x-ray fluorescence: a feasibility study

被引:19
作者
Cho, H-M [1 ]
Ding, H. [1 ]
Ziemer, B. P. [1 ]
Molloi, S. [1 ]
机构
[1] Univ Calif Irvine, Dept Radiol Sci, Irvine, CA 92697 USA
关键词
photon-counting detector; x-ray fluorescence; energy calibration; COMPUTED-TOMOGRAPHY XFCT; CT; RESOLUTION; RADIATION;
D O I
10.1088/0031-9155/59/23/7211
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Accurate energy calibration is critical for the application of energy-resolved photon-counting detectors in spectral imaging. The aim of this study is to investigate the feasibility of energy response calibration and characterization of a photon-counting detector using x-ray fluorescence. A comprehensive Monte Carlo simulation study was performed using Geant4 Application for Tomographic Emission (GATE) to investigate the optimal technique for x-ray fluorescence calibration. Simulations were conducted using a 100 kVp tungsten-anode spectra with 2.7 mm Al filter for a single pixel cadmium telluride (CdTe) detector with 3 x 3 mm(2) in detection area. The angular dependence of x-ray fluorescence and scatter background was investigated by varying the detection angle from 20 degrees to 170 degrees with respect to the beam direction. The effects of the detector material, shape, and size on the recorded x-ray fluorescence were investigated. The fluorescent material size effect was considered with and without the container for the fluorescent material. In order to provide validation for the simulation result, the angular dependence of x-ray fluorescence from five fluorescent materials was experimentally measured using a spectrometer. Finally, eleven of the fluorescent materials were used for energy calibration of a CZT-based photon-counting detector. The optimal detection angle was determined to be approximately at 120 degrees with respect to the beam direction, which showed the highest fluorescence to scatter ratio (FSR) with a weak dependence on the fluorescent material size. The feasibility of x-ray fluorescence for energy calibration of photon-counting detectors in the diagnostic x-ray energy range was verified by successfully calibrating the energy response of a CZT-based photon-counting detector. The results of this study can be used as a guideline to implement the x-ray fluorescence calibration method for photon-counting detectors in a typical imaging laboratory.
引用
收藏
页码:7211 / 7227
页数:17
相关论文
共 34 条
[1]   Order of Magnitude Sensitivity Increase in X-ray Fluorescence Computed Tomography (XFCT) Imaging With an Optimized Spectro-Spatial Detector Configuration: Theory and Simulation [J].
Ahmad, Moiz ;
Bazalova, Magdalena ;
Xiang, Liangzhong ;
Xing, Lei .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2014, 33 (05) :1119-1128
[2]  
[Anonymous], MED PHYS
[3]   The Medipix3RX: a high resolution, zero dead-time pixel detector readout chip allowing spectroscopic imaging [J].
Ballabriga, R. ;
Alozy, J. ;
Blaj, G. ;
Campbell, M. ;
Fiederle, M. ;
Frojdh, E. ;
Heijne, E. H. M. ;
Llopart, X. ;
Pichotka, M. ;
Procz, S. ;
Tlustos, L. ;
Wong, W. .
JOURNAL OF INSTRUMENTATION, 2013, 8
[4]   Characterization of the Medipix3 pixel readout chip [J].
Ballabriga, R. ;
Blaj, G. ;
Campbell, M. ;
Fiederle, M. ;
Greiffenberg, D. ;
Heijne, E. H. M. ;
Llopart, X. ;
Plackett, R. ;
Procz, S. ;
Tlustos, L. ;
Turecek, D. ;
Wong, W. .
JOURNAL OF INSTRUMENTATION, 2011, 6
[5]  
Barber W.C., 2009, P SPIE MEDICAL IMAGI, V7258, P725824, DOI [DOI 10.1117/12.813915, 10.1117/12.813915]
[6]   Investigation of X-ray Fluorescence Computed Tomography (XFCT) and K-Edge Imaging [J].
Bazalova, Magdalena ;
Kuang, Yu ;
Pratx, Guillem ;
Xing, Lei .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2012, 31 (08) :1620-1627
[7]  
Bushberg JT., 2011, ESSENTIAL PHYS MED I
[8]  
Chauvie S, 2001, PROCEEDINGS OF CHEP 2001, P337
[9]   X-ray fluorescence computed tomography (XFCT) imaging of gold nanoparticle-loaded objects using 110 kVp x-rays [J].
Cheong, Seong-Kyun ;
Jones, Bernard L. ;
Siddiqi, Arsalan K. ;
Liu, Fang ;
Manohar, Nivedh ;
Cho, Sang Hyun .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (03) :647-662
[10]   Image-based spectral distortion correction for photon-counting x-ray detectors [J].
Ding, Huanjun ;
Molloi, Sabee .
MEDICAL PHYSICS, 2012, 39 (04) :1864-1876