摘要
The confinement effect of fiber-reinforced polymer (FRP) jacket on the plastic hinge length of square RC columns is studied through experimental testing and analytical study. Seven half-scale RC square columns with different confinement ratios were tested. The strain of longitudinal reinforcement bars and the extent of yielding were measured by strain gauges mounted inside the reinforcement bars. The variation of the strain field of the external column face was recorded continuously by digital image correlation (DIC) during a test. More rational approaches of data analysis are used for identification of plastic hinge length from measured strain fields. The obtained results show that compared with unconfined RC columns, FRP jacketing increases the plastic hinge length when the confinement level is low, but reduces it when the confinement level is high. The analytical study shows that all existing models of plastic hinge length are inadequate in one way or another because no model includes all important factors. The proposed model can correctly capture the trends but it needs to be further improved for accuracy when more data are available. (C) 2014 American Society of Civil Engineers.
引用
收藏
页数:12
相关论文
共 36 条
[1]  
Berry M.P., 2006, Ph.D. Thesis
[2]   Design of FRPs in circular bridge column retrofits for ductility enhancement [J].
Binici, Baris .
ENGINEERING STRUCTURES, 2008, 30 (03) :766-776
[3]  
Biskinis D, 2010, STRUCT CONCRETE, V11, P93, DOI [10.1680/stco.2010.11.2.93, 10.1680/stco.2010.11.2.93]]
[4]   Models for FRP-wrapped rectangular RC columns with continuous or lap-spliced bars under cyclic lateral loading [J].
Biskinis, Dionysis ;
Fardis, Michael N. .
ENGINEERING STRUCTURES, 2013, 57 :199-212
[5]   Digital image correlation analysis of interfacial debonding properties and fracture behavior in concrete [J].
Corr, David ;
Accardi, Matteo ;
Graham-Brady, Lori ;
Shah, Surendra .
ENGINEERING FRACTURE MECHANICS, 2007, 74 (1-2) :109-121
[6]   Analysis of Cracks and Deformations in a Full Scale Reinforced Concrete Beam Using a Digital Image Correlation Technique [J].
Destrebecq, J. -F. ;
Toussaint, E. ;
Ferrier, E. .
EXPERIMENTAL MECHANICS, 2011, 51 (06) :879-890
[7]  
Elsanadedy HM, 2005, ACI STRUCT J, V102, P505
[8]  
Federation Internationale du Beton, 2010, BULLETIN, V65/66
[9]   Plastic hinge analysis of FRP confined circular concrete columns [J].
Gu, Dong-Sheng ;
Wu, Yu-Fei ;
Wu, Gang ;
Wu, Zhi-shen .
CONSTRUCTION AND BUILDING MATERIALS, 2012, 27 (01) :223-233
[10]   Confinement Effectiveness of FRP in Retrofitting Circular Concrete Columns under Simulated Seismic Load [J].
Gu, Dong-Sheng ;
Wu, Gang ;
Wu, Zhi-Shen ;
Wu, Yu-Fei .