Nobori Biolimus-Eluting Stent vs. Permanent Polymer Drug-Eluting Stents in Patients Undergoing Percutaneous Coronary Intervention - Meta-Analysis of Randomized Clinical Trials

被引:11
作者
Danzi, Gian Battista [1 ]
Piccolo, Raffaele [2 ]
Galasso, Gennaro [2 ]
Piscione, Federico [3 ]
机构
[1] Osped Santa Corona, Div Cardiol, I-17027 Pietra Ligure, Italy
[2] Univ Naples Federico II, Dept Adv Biomed Sci, Naples, Italy
[3] Univ Salerno, Dept Med & Surg, I-84100 Salerno, Italy
关键词
Biodegradable polymers; Drug-eluting stents; Meta-analyses; Nobori biolimus-eluting stent; Percutaneous coronary intervention; LONG-TERM OUTCOMES; BARE-METAL STENTS; BIODEGRADABLE POLYMER; DURABLE POLYMER; MYOCARDIAL-INFARCTION; ARTERY-DISEASE; THROMBOSIS; LEADERS; REVASCULARIZATION; IMPLANTATION;
D O I
10.1253/circj.CJ-13-1558
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Permanent polymer coatings on drug-eluting stents (DES) surface have been identified as triggers of adverse events following percutaneous coronary intervention (PCI). However, efficacy and safety data for the Nobori biolimus-eluting stent (BES), a biodegradable polymer DES, are limited, so the aim of this study was to evaluate clinical outcomes associated with the Nobori BES compared with permanent polymer DES in patients undergoing PCI. Methods and Results: Randomized trials comparing Nobori BES vs. other DES were included in the meta-analysis. The 12-month clinical endpoints were: target lesion revascularization (TLR), all-cause mortality, myocardial infarction (MI) and stent thrombosis (ST). Seven trials totaling 12,090 PCI patients met the inclusion criteria. Nobori BES vs. other DES had a comparable risk of TLR (odds ratio [OR] 0.94; 95% confidence interval [CI], 0.66-1.34; P=0.74), mortality (OR 1.00; 95% CI, 0.78-1.28; P=0.98), MI (OR 1.10; 95% CI, 0.87-1.40; P=0.42) and definite/probable ST (OR 1.01; 95% CI, 0.45-2.25; P=0.99). Despite Nobori BES showing similar clinical results to sirolimus-, everolimus-and zotarolimus-eluting stents, it was superior to paclitaxel-eluting stents in reducing the risk of TLR (OR 0.31; 95% CI, 0.10-0.90; P=0.03) Conclusions: Nobori BES use is associated with a similar safety and efficacy as permanent polymer DES at 1-year follow-up, albeit it is superior to paclitaxel-eluting stents in terms of TLR. Long-term follow-up data are needed in order to establish whether polymer degradation related to Nobori BES implantation improves clinical outcomes.
引用
收藏
页码:1858 / +
页数:13
相关论文
共 41 条
[31]   Effect of drug-eluting stents in patients with acute ST-segment elevation myocardial infarction undergoing percutaneous coronary intervention: a meta-analysis of randomised trials and an adjusted indirect comparison [J].
Piscione, Federico ;
Piccolo, Raffaele ;
Cassese, Salvatore ;
Galasso, Gennaro ;
De Rosa, Roberta ;
D'Andrea, Claudia ;
Chiariello, Massimo .
EUROINTERVENTION, 2010, 5 (07) :853-860
[32]   Very Late Coronary Stent Thrombosis of a Newer-Generation Everolimus-Eluting Stent Compared With Early-Generation Drug-Eluting Stents A Prospective Cohort Study [J].
Raeber, Lorenz ;
Magro, Michael ;
Stefanini, Giulio G. ;
Kalesan, Bindu ;
van Domburg, Ron T. ;
Onuma, Yoshinobu ;
Wenaweser, Peter ;
Daemen, Joost ;
Meier, Bernhard ;
Jueni, Peter ;
Serruys, Patrick W. ;
Windecker, Stephan .
CIRCULATION, 2012, 125 (09) :1110-U108
[33]   Lower risk of stent thrombosis and restenosis with unrestricted use of onew-generation' drug-eluting stents: a report from the nationwide Swedish Coronary Angiography and Angioplasty Registry (SCAAR) [J].
Sarno, Giovanna ;
Lagerqvist, Bo ;
Frobert, Ole ;
Nilsson, Johan ;
Olivecrona, Goran ;
Omerovic, Elmir ;
Saleh, Nawzad ;
Venetzanos, Dimitris ;
James, Stefan .
EUROPEAN HEART JOURNAL, 2012, 33 (05) :606-613
[34]   Improved Safety and Reduction in Stent Thrombosis Associated With Biodegradable Polymer-Based Biolimus-Eluting Stents Versus Durable Polymer-Based Sirolimus-Eluting Stents in Patients With Coronary Artery Disease Final 5-Year Report of the LEADERS (Limus Eluted From A Durable Versus ERodable Stent Coating) Randomized, Noninferiority Trial [J].
Serruys, Patrick W. ;
Farooq, Vasim ;
Kalesan, Bindu ;
de Vries, Ton ;
Buszman, Pawel ;
Linke, Axel ;
Ischinger, Thomas ;
Klauss, Volker ;
Eberli, Franz ;
Wijns, William ;
Morice, Marie Claude ;
Di Mario, Carlo ;
Corti, Roberto ;
Antoni, Diethmar ;
Sohn, Hae Y. ;
Eerdmans, Pedro ;
Rademaker-Havinga, Tessa ;
van Es, Gerrit-Anne ;
Meier, Bernhard ;
Jueni, Peter ;
Windecker, Stephan .
JACC-CARDIOVASCULAR INTERVENTIONS, 2013, 6 (08) :777-789
[35]   Abluminal biodegradable polymer biolimus-eluting stent versus durable polymer everolimus-eluting stent (COMPARE II): a randomised, controlled, non-inferiority trial [J].
Smits, Pieter Cornelis ;
Hofma, Sjoerd ;
Togni, Mario ;
Vazquez, Nicolas ;
Valdes, Mariano ;
Voudris, Vassilis ;
Slagboom, Ton ;
Goy, Jean-Jaques ;
Vuillomenet, Andre ;
Serra, Antoni ;
Trillo Nouche, Ramiro ;
den Heijer, Peter ;
van der Ent, Martin .
LANCET, 2013, 381 (9867) :651-660
[36]   Drug-Eluting Coronary-Artery Stents [J].
Stefanini, Giulio G. ;
Holmes, David R., Jr. .
NEW ENGLAND JOURNAL OF MEDICINE, 2013, 368 (03) :254-265
[37]   Biodegradable polymer drug-eluting stents reduce the risk of stent thrombosis at 4 years in patients undergoing percutaneous coronary intervention: a pooled analysis of individual patient data from the ISAR-TEST 3, ISAR-TEST 4, and LEADERS randomized trials [J].
Stefanini, Giulio G. ;
Byrne, Robert A. ;
Serruys, Patrick W. ;
de Waha, Antoinette ;
Meier, Bernhard ;
Massberg, Steffen ;
Jueni, Peter ;
Schoemig, Albert ;
Windecker, Stephan ;
Kastrati, Adnan .
EUROPEAN HEART JOURNAL, 2012, 33 (10) :1214-1222
[38]   Can trial sequential monitoring boundaries reduce spurious inferences from meta-analyses? [J].
Thorlund, Kristian ;
Devereaux, P. J. ;
Wetterslev, Jorn ;
Guyatt, Gordon ;
Ioannidis, John P. A. ;
Thabane, Lehana ;
Gluud, Lise-Lotte ;
Als-Nielsen, Bodil ;
Gluud, Christian .
INTERNATIONAL JOURNAL OF EPIDEMIOLOGY, 2009, 38 (01) :276-286
[39]   Trial sequential analysis may establish when firm evidence is reached in cumulative meta-analysis [J].
Wetterslev, Jorn ;
Thorlund, Kristian ;
Brok, Jesper ;
Gluud, Christian .
JOURNAL OF CLINICAL EPIDEMIOLOGY, 2008, 61 (01) :64-75
[40]   Comparison of Inflammatory Response After Implantation of Sirolimus- and Paclitaxel-Eluting Stents in Porcine Coronary Arteries [J].
Wilson, Gregory J. ;
Nakazawa, Gaku ;
Schwartz, Robert S. ;
Huibregtse, Barbara ;
Poff, Bradley ;
Herbst, Thomas J. ;
Baim, Donald S. ;
Virmani, Renu .
CIRCULATION, 2009, 120 (02) :141-U75