3D Late Gadolinium Enhancement in a Single Prolonged Breath-Hold using Supplemental Oxygenation and Hyperventilation

被引:12
作者
Roujol, Sebastien [1 ,2 ]
Basha, Tamer A. [1 ,2 ]
Akcakaya, Mehmet [1 ,2 ]
Foppa, Murilo [1 ,2 ]
Chan, Raymond H. [1 ,2 ]
Kissinger, Kraig V. [1 ,2 ]
Goddu, Beth [1 ,2 ]
Berg, Sophie [1 ,2 ]
Manning, Warren J. [1 ,2 ,3 ]
Nezafat, Reza [1 ,2 ]
机构
[1] Beth Israel Deaconess Med Ctr, Dept Med, Div Cardiovasc, Boston, MA 02215 USA
[2] Harvard Univ, Sch Med, Boston, MA USA
[3] Beth Israel Deaconess Med Ctr, Dept Radiol, Boston, MA 02215 USA
基金
美国国家卫生研究院;
关键词
late gadolinium enhancement; myocardial viability; 3D acquisition; acceleration techniques; breath-hold; left ventricle; hyperventilation; compressed sensing; SENSITIVE INVERSION-RECOVERY; CORONARY MR-ANGIOGRAPHY; MYOCARDIAL-INFARCTION; DELAYED HYPERENHANCEMENT; IMAGE-RECONSTRUCTION; ATRIAL-FIBRILLATION; SPATIAL-RESOLUTION; CARDIAC MR; VIABILITY; MOTION;
D O I
10.1002/mrm.24969
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the feasibility of three-dimensional (3D) single breath-hold late gadolinium enhancement (LGE) of the left ventricle (LV) using supplemental oxygen and hyperventilation and compressed-sensing acceleration. Methods: Breath-hold metrics [breath-hold duration, diaphragmatic/LV position drift, and maximum variation of R wave to R wave (RR) interval] without and with supplemental oxygen and hyperventilation were assessed in healthy adult subjects using a real-time single shot acquisition. Ten healthy subjects and 13 patients then underwent assessment of the proposed 3D breath-hold LGE acquisition (field of view = 320 x 320 x 100 mm(3), resolution = 1.6 x 1.6 x 5.0 mm(3), acceleration rate of 4) and a free-breathing acquisition with right hemidiaphragm navigator (NAV) respiratory gating. Semiquantitative grading of overall image quality, motion artifact, myocardial nulling, and diagnostic value was performed by consensus of two blinded observers. Results: Supplemental oxygenation and hyperventilation increased the breath-hold duration (35+/-11 s to 58+/-21 s; P< 0.0125) without significant impact on diaphragmatic/LV position drift or maximum variation of RR interval (both P> 0.01). LGE images were of similar quality when compared with free-breathing acquisitions, but with reduced total scan time (85+/-22 s to 35+/-6 s; P< 0.001). Conclusions: Supplemental oxygenation and hyperventilation allow for prolonged breath-holding and enable single breath-hold 3D accelerated LGE with similar image quality as free breathing with NAV. (C) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:850 / 857
页数:8
相关论文
共 42 条
  • [1] Accelerated Late Gadolinium Enhancement Cardiac MR Imaging with Isotropic Spatial Resolution Using Compressed Sensing: Initial Experience1
    Akcakaya, Mehmet
    Rayatzadeh, Hussein
    Basha, Tamer A.
    Hong, Susie N.
    Chan, Raymond H.
    Kissinger, Kraig V.
    Hauser, Thomas H.
    Josephson, Mark E.
    Manning, Warren J.
    Nezafat, Reza
    [J]. RADIOLOGY, 2012, 264 (03) : 691 - 699
  • [2] Low-dimensional-Structure Self-Learning and Thresholding: Regularization Beyond Compressed Sensing for MRI Reconstruction
    Akcakaya, Mehmet
    Basha, Tamer A.
    Goddu, Beth
    Goepfert, Lois A.
    Kissinger, Kraig V.
    Tarokh, Vahid
    Manning, Warren J.
    Nezafat, Reza
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (03) : 756 - 767
  • [3] Assessment of Myocardial Viability with 3D MRI at 3 T
    Bauner, Kerstin U.
    Muehling, Olaf
    Theisen, Daniel
    Hayes, Carmel
    Wintersperger, Bernd J.
    Reiser, Maximilian F.
    Huber, Armin M.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (06) : 1645 - 1650
  • [4] Undersampled radial MRI with multiple coils. Iterative image reconstruction using a total variation constraint
    Block, Kai Tobias
    Uecker, Martin
    Frahm, Jens
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (06) : 1086 - 1098
  • [5] Role of chemoreceptors in mediating dyspnea
    Buchanan, Gordon F.
    Richerson, George B.
    [J]. RESPIRATORY PHYSIOLOGY & NEUROBIOLOGY, 2009, 167 (01) : 9 - 19
  • [6] Navigator assessment of breath-hold duration: Impact of supplemental oxygen and hyperventilation
    Danias, PG
    Stuber, M
    Botnar, RM
    Kissinger, KV
    Chuang, ML
    Manning, WJ
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (02) : 395 - 397
  • [7] Myocardial viability: Assessment with three-dimensional MR imaging in pigs and patients
    Dewey, M
    Laule, M
    Taupitz, M
    Kaufels, N
    Hamm, B
    Kivelitz, D
    [J]. RADIOLOGY, 2006, 239 (03) : 703 - 709
  • [8] Myocardial viability: Breath-hold 3D MR imaging of delayed hyperenhancement with variable sampling in time
    Foo, TKF
    Stanley, DW
    Castillo, E
    Rochitte, CE
    Wang, Y
    Lima, JAC
    Bluemke, DA
    Wu, KC
    [J]. RADIOLOGY, 2004, 230 (03) : 845 - 851
  • [9] BREATH-HOLDING CAPABILITY OF ADULTS - IMPLICATIONS FOR SPIRAL COMPUTED-TOMOGRAPHY, FAST-ACQUISITION MAGNETIC-RESONANCE-IMAGING, AND ANGIOGRAPHY
    GAY, SB
    SISTROM, CL
    HOLDER, CA
    SURATT, PM
    [J]. INVESTIGATIVE RADIOLOGY, 1994, 29 (09) : 848 - 851
  • [10] Acute, Subacute, and Chronic Myocardial Infarction: Quantitative Comparison of 2D and 3D Late Gadolinium Enhancement MR Imaging
    Goetti, Robert
    Kozerke, Sebastian
    Donati, Olivio F.
    Suerder, Daniel
    Stolzmann, Paul
    Kaufmann, Philipp A.
    Luescher, Thomas F.
    Corti, Roberto
    Manka, Robert
    [J]. RADIOLOGY, 2011, 259 (03) : 704 - 711