Correlation of diffusion-weighted magnetic resonance data with cellularity in prostate cancer

被引:198
作者
Zelhof, Bashar [1 ]
Pickles, Martin [1 ]
Liney, Gary [1 ]
Gibbs, Peter [1 ]
Rodrigues, Greta [2 ]
Kraus, Sigurd [3 ]
Turnbull, Lindsay [1 ]
机构
[1] Univ Hull, Ctr MR Invest, Kingston Upon Hull HU6 7RX, N Humberside, England
[2] Hull & E Yorkshire NHS Trust, Dept Pathol, Kingston Upon Hull, N Humberside, England
[3] Hull & E Yorkshire NHS Trust, Dept Urol, Kingston Upon Hull, N Humberside, England
关键词
diffusion-weighted imaging; MRI; prostate cancer; cell density; MICROVESSEL DENSITY; PERIPHERAL ZONES; CELL-DENSITY; BRAIN-TUMORS; T; MRI; ECHO; DIFFERENTIATION; COEFFICIENT; TISSUE;
D O I
10.1111/j.1464-410X.2008.08130.x
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
To assess the relationship between the apparent diffusion coefficient (ADC) on magnetic resonance imaging (MRI) and cell density (CD) obtained from radical prostatectomy (RP) specimens. In all, 36 patients with prostate cancer were recruited; T2-weighted and diffusion-weighted MRI was obtained axially using a 3.0 T scanner. Patients then proceeded to RP; the prostate was whole-mounted and sectioned axially. Slices (3 mu m) were cut from the surface of each section and stained with haematoxylin and eosin (H&E). Five randomly positioned areas from the tumour and normal peripheral zone (PZ) were examined by light microscopy at x 200, then digitally photographed and analysed to obtain automatic CD. ADC values were determined from the MRI data using the H&E slides as a reference. ADC and CD values were measured in both malignant lesions and the PZ, and the correlation between ADC and CD assessed. ADC values were lower (P <= 0.001) in regions pathologically determined as tumour, with a mean (sd) of 1.45 (0.26) x 10(-3) mm(2)/s, vs normal PZ, of 1.90 (0.33) x 10(-3) mm(2)/s. Similarly, the mean CD over the five fields was higher (P <= 0.001) in tumour than in normal PZ, with values of 18.89 (4.93)% vs 9.22 (3.23)%. There was a significant correlation between the ADC values and CD (r = -0.50, P < 0.001) regardless of tissue type. CD values were high in cancer which had lower ADC values than normal PZ. ADC values were correlated successfully with CD; this information cannot be obtained with conventional MRI and is useful in characterizing prostate cancer.
引用
收藏
页码:883 / 888
页数:6
相关论文
共 36 条
[1]  
Brawer MK, 1996, CANCER, V78, P345, DOI 10.1002/(SICI)1097-0142(19960715)78:2<345::AID-CNCR25>3.0.CO
[2]  
2-V
[3]  
Chenevert TL, 1997, CLIN CANCER RES, V3, P1457
[4]   Magnetic resonance imaging in prostate cancer: the value of apparent diffusion coefficients for identifying malignant nodules [J].
DeSouza, N. M. ;
Reinsberg, S. A. ;
Scurr, E. D. ;
Brewster, J. M. ;
Payne, G. S. .
BRITISH JOURNAL OF RADIOLOGY, 2007, 80 (950) :90-95
[5]   Estimates of the cancer incidence and mortality in Europe in 2006 [J].
Ferlay, J. ;
Autier, P. ;
Boniol, M. ;
Heanue, M. ;
Colombet, M. ;
Boyle, P. .
ANNALS OF ONCOLOGY, 2007, 18 (03) :581-592
[6]   Diffusion imaging of the prostate at 3.0 tesla [J].
Gibbs, P ;
Pickles, MD ;
Turnbull, LW .
INVESTIGATIVE RADIOLOGY, 2006, 41 (02) :185-188
[7]   Comparison of quantitative T2 mapping and diflusion-weighted imaging in the normal and pathologic prostate [J].
Gibbs, P ;
Tozer, DJ ;
Liney, GP ;
Turnbull, LW .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (06) :1054-1058
[8]   Repeatability of echo-planar-based diffusion measurements of the human prostate at 3 T [J].
Gibbs, Peter ;
Pickles, Martin D. ;
Turnbull, Lindsay W. .
MAGNETIC RESONANCE IMAGING, 2007, 25 (10) :1423-1429
[9]   Differentiation of clinically benign and malignant breast lesions using diffusion-weighted imaging [J].
Guo, Y ;
Cai, YQ ;
Cai, ZL ;
Gao, YG ;
An, NY ;
Ma, L ;
Mahankali, S ;
Gao, JH .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 16 (02) :172-178
[10]   Combined T2-weighted and diffusion-weighted MRI for localization of prostate cancer [J].
Haider, Masoom A. ;
van der Kwast, Theodorus H. ;
Tanguay, Jeff ;
Evans, Andrew J. ;
Hashmi, Ali-Tahir ;
Lockwood, Gina ;
Trachtenberg, John .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 189 (02) :323-328