Warning of accidental shadowing of a PV generator in operation analyzed with the DoE method

被引:6
作者
Charles, J-P. [1 ,2 ]
Aillerie, M. [1 ,2 ]
Petit, P. [1 ,2 ]
Humane, F. [3 ]
El Mossaoui, H. [3 ]
机构
[1] Univ Lorraine, LMOPS EA 4423, Metz, France
[2] CentraleSupelec, LMOPS, Metz, France
[3] Univ Saad Dahlab, LAFPC, Blida 09000, Algeria
关键词
Energy management; Smart operating PV system; Accidental shadowing detection; Operation control; Design of Experiments; PHOTOVOLTAIC ARRAYS; SIMULATION; SYSTEM; EFFICIENT; TRACKERS; MODEL;
D O I
10.1016/j.solener.2015.09.002
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper presents a practical method to detect any accidental partial shadowing on an operating photovoltaic (PV) panel in a smart generation system including a control center. Given a known solar irradiance level and temperature it is possible to make an automatic estimation of the output electrical power and to trigger an alarm in case of an accidental shadowing occurrence. Preliminary field measurements data are taken to evaluate the PV panel parameters once and for all. Simulation of the panel in operation is performed with the mathematical method of Design of Experiments (DoE): the maximum power parameter is considered as critical for the protection and security of the PV panel. Its value is computed and any amount of partial shadowing is then detected from the difference between the measured and the calculated values of this parameter. This method can be easily implemented in any smart PV generation system as an alarm trigger in actual operation to insure complete safety of the generation system. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:455 / 463
页数:9
相关论文
共 29 条
[1]  
[Anonymous], 2011, IEEE POW EN SOC GEN
[2]  
[Anonymous], 1925, Statistical methods for research workers
[3]  
[Anonymous], 2011, The Third Industrial Revolution: How Lateral Power Is Transforming Energy, the Economy, and the World
[4]   Photochemically produced quasi-linear copolymers for stable and efficient electrolytes in dye-sensitized solar cells [J].
Bella, Federico ;
Imperiyka, Mahamed ;
Ahmad, Azizan .
JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 2014, 289 :73-80
[5]   Towards green, efficient and durable quasi-solid dye-sensitized solar cells integrated with a cellulose-based gel-polymer electrolyte optimized by a chemometric DoE approach [J].
Bella, Federico ;
Nair, Jijeesh R. ;
Gerbaldi, Claudio .
RSC ADVANCES, 2013, 3 (36) :15993-16001
[6]   A single procedure for helping PV designers to select silicon PV modules and evaluate the loss resistances [J].
Carrero, C. ;
Amador, J. ;
Arnaltes, S. .
RENEWABLE ENERGY, 2007, 32 (15) :2579-2589
[7]   Faulty PV panel identification using the Design of Experiments (DoE) method [J].
Charles, J. -P. ;
Hannane, F. ;
El-Mossaoui, H. ;
Zegaoui, A. ;
Nguyen, T. V. ;
Petit, P. ;
Aillerie, M. .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2014, 57 :31-38
[8]   Modeling and simulation of a grid connected PV system based on the evaluation of main PV module parameters [J].
Chouder, Aissa ;
Silvestre, Santiago ;
Sadaoui, Nawel ;
Rahmani, Lazhar .
SIMULATION MODELLING PRACTICE AND THEORY, 2012, 20 (01) :46-58
[9]   Optimal distribution for photovoltaic solar trackers to minimize power losses caused by shadows [J].
Diaz-Dorado, Eloy ;
Suarez-Garcia, Andres ;
Carrillo, Camilo J. ;
Cidras, Jose .
RENEWABLE ENERGY, 2011, 36 (06) :1826-1835
[10]  
El-Mossaoui H, 2004, THESIS