First In-Human Results of Computed Tomography Angiography for Coronary Stent Assessment With a Spectral Photon Counting Computed Tomography

被引:88
作者
Boccalini, Sara [1 ,2 ]
Si-Mohamed, Salim A. [1 ,2 ]
Lacombe, Hugo [1 ]
Diaw, Adja [1 ]
Varasteh, Mohammad [1 ]
Rodesch, Pierre-Antoine [1 ]
Villien, Marjorie [3 ]
Sigovan, Monica [1 ]
Dessouky, Riham [4 ]
Coulon, Philippe [3 ]
Yagil, Yoad [5 ]
Lahoud, Elias [5 ]
Erhard, Klaus [6 ]
Rioufol, Gilles [7 ]
Finet, Gerard [7 ]
Bonnefoy-Cudraz, Eric [7 ]
Bergerot, Cyrille [7 ]
Boussel, Loic [1 ,2 ]
Douek, Philippe C. [1 ,2 ]
机构
[1] Univ Lyon, INSA Lyon, Univ Claude Bernard Lyon 1, UJM St Etienne,CNRS,INSERM, Villeurbanne, France
[2] Hosp Civils Lyon, Dept Cardiovasc & Thorac Radiol, Louis Pradel Hodp, Bron, France
[3] Philips Healthcare, Suresnes, France
[4] Zagazig Univ, Fac Med, Dept Radiol, Zagazig, Egypt
[5] Philips Healthcare, Haifa, Israel
[6] Philips Res, Hamburg, Germany
[7] Hosp Civils Lyon, Louis Pradel Hosp, Dept Cardiol, Bron, France
基金
欧盟地平线“2020”;
关键词
coronary stents; photon counting CT; coronary CT angiography; image quality; CT; FEASIBILITY; RESTENOSIS;
D O I
10.1097/RLI.0000000000000835
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives The aim of this study is to compare the image quality of in vivo coronary stents between an energy integrating detectors dual-layer computed tomography (EID-DLCT) and a clinical prototype of spectral photon counting computed tomography (SPCCT). Materials and Methods In January to June 2021, consecutive patients with coronary stents were prospectively enrolled to undergo a coronary computed tomography (CT) with an EID-DLCT (IQon, Philips) and an SPCCT (Philips). The study was approved by the local ethical committee and patients signed an informed consent. A retrospectively electrocardiogram-gated acquisition was performed with optimized matching parameters on the 2 scanners (EID-DLCT: collimation, 64 x 0.625 mm; kVp, 120, automatic exposure control with target current at 255 mAs; rotation time, 0.27 seconds; SPCCT: collimation, 64 x 0.275 mm; kVp, 120; mAs, 255; rotation time, 0.33 seconds). The injection protocol was the same on both scanners: 65 to 75 mL of Iomeron (Bracco) at 5 mL/s. Images were reconstructed with slice thickness of 0.67 mm, 512 matrix, XCB (Xres cardiac standard) and XCD (Xres cardiac detailed) kernel, iDose 3 for EID-DLCT and 0.25-mm slice thickness, 1024 matrix, Detailed 2 and Sharp kernel, and iDose 6 for SPCCT. Two experienced observers measured the proximal and distal external and internal diameters of the stents to quantify blooming artifacts. Regions of interest were drawn in the lumen of the stent and of the upstream coronary artery. The difference (Delta S-C) between the respective attenuation values was calculated as a quantification of stent-induced artifacts on intrastent image quality. For subjective image quality, 3 experienced observers graded with a 4-point scale the image quality of different parameters: coronary wall before the stent, stent lumen, stent structure, calcifications surrounding the stent, and beam-hardening artifacts. Results Eight patients (age, 68 years [interquartile range, 8]; all men; body mass index, 26.2 kg/m(2) [interquartile range, 4.2]) with 16 stents were scanned. Five stents were not evaluable owing to motion artifacts on the SPCCT. Of the remaining, all were drug eluting stents, of which 6 were platinum-chromium, 3 were cobalt-platinum-iridium, and 1 was stainless steel. For 1 stent, no information could be retrieved. Radiation dose was lower with the SPCCT (fixed CT dose index of 25.7 mGy for SPCCT vs median CT dose index of 35.7 [IQ = 13.6] mGy; P = 0.02). For 1 stent, the internal diameter was not assessable on EID-DLCT. External diameters were smaller and internal diameters were larger with SPCCT (all P < 0.05). Consequently, blooming artifacts were reduced on SPCCT (P < 0.05). Whereas Hounsfield unit values within the coronary arteries on the 2 scanners were similar, the Delta S-C was lower for SPCCT-Sharp as compared with EID-DLCT-XCD and SPCCT-Detailed 2 (P < 0.05). The SPCCT received higher subjective scores than EID-DLCT for stent lumen, stent structure, surrounding calcifications and beam-hardening for both Detailed 2 and Sharp (all P <= 0.05). The SPCCT-Sharp was judged better for stent structure and beam-hardening assessment as compared with SPCCT-Detailed 2. Conclusion Spectral photon counting CT demonstrated improved objective and subjective image quality as compared with EID-DLCT for the evaluation of coronary stents even with a reduced radiation dose.
引用
收藏
页码:212 / 221
页数:10
相关论文
共 33 条
[1]   Intravascular Ultrasound Versus Optical Coherence Tomography Guidance [J].
不详 .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 62 (17) :S32-S40
[2]   Artifacts in CT: Recognition and avoidance [J].
Barrett, JF ;
Keat, N .
RADIOGRAPHICS, 2004, 24 (06) :1679-1691
[3]   Feasibility of human vascular imaging of the neck with a large field-of-view spectral photon-counting CT system [J].
Boccalini, Sara ;
Si-Mohamed, Salim ;
Dessouky, Riham ;
Sigovan, Monica ;
Boussel, Loic ;
Douek, Philippe .
DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2021, 102 (05) :329-332
[4]   Computed tomography image quality of aortic stents in patients with aortic coarctation: a multicentre evaluation [J].
Boccalini S. ;
den Harder A.M. ;
Witsenburg M. ;
Breur J.P.J.M. ;
Krestin G.P. ;
van Beynum I.M. ;
Attrach M. ;
Stagnaro N. ;
Marasini M. ;
de Jong P.A. ;
Leiner T. ;
Budde R.P.J. .
European Radiology Experimental, 2 (1)
[5]   Spectral Photon-Counting Computed Tomography for Coronary Stent Imaging Evaluation of the Potential Clinical Impact for the Delineation of In-Stent Restenosis [J].
Bratke, Grischa ;
Hickethier, Tilman ;
Bar-Ness, Daniel ;
Bunck, Alexander Christian ;
Maintz, David ;
Pahn, Gregor ;
Coulon, Philippe ;
Si-Mohamed, Salim ;
Douek, Philippe ;
Sigovan, Monica .
INVESTIGATIVE RADIOLOGY, 2020, 55 (02) :61-67
[6]  
Collet JP, 2021, REV ESP CARDIOL, V74, DOI [10.1016/j.rec.2021.05.002, 10.1093/eurheartj/ehaa575]
[7]   Diagnostic performance of computed tomography angiography in the detection of coronary artery in-stent restenosis: evidence from an updated meta-analysis [J].
Dai, Tao ;
Wang, Jiang-rong ;
Hu, Peng-fei .
EUROPEAN RADIOLOGY, 2018, 28 (04) :1373-1382
[8]   Diagnostic Accuracy of 320-Row Multidetector Computed Tomography Coronary Angiography to Noninvasively Assess In-Stent Restenosis [J].
de Graaf, Fleur R. ;
Schuijf, Joanne D. ;
van Velzen, Joella E. ;
Boogers, Mark J. ;
Kroft, Lucia J. ;
de Roos, Albert ;
Reiber, Johannes H. C. ;
Sieders, Allard ;
Spano, Fabrizio ;
Jukema, J. Wouter ;
Schalij, Martin J. ;
van der Wall, Ernst E. ;
Bax, Jeroen J. .
INVESTIGATIVE RADIOLOGY, 2010, 45 (06) :331-340
[9]   2019 ESC Guidelines for the diagnosis and management of chronic coronary syndromes The Task Force for the diagnosis and management of chronic coronary syndromes of the European Society of Cardiology (ESC) [J].
Knuuti, Juhani ;
Wijns, William ;
Saraste, Antti ;
Capodanno, Davide ;
Barbato, Emanuele ;
Funck-Brentano, Christian ;
Prescott, Eva ;
Storey, Robert F. ;
Deaton, Christi ;
Cuisset, Thomas ;
Agewall, Stefan ;
Dickstein, Kenneth ;
Edvardsen, Thor ;
Escaned, Javier ;
Gersh, Bernard J. ;
Svitil, Pavel ;
Gilard, Martine ;
Hasdai, David ;
Hatala, Robert ;
Mahfoud, Felix ;
Masip, Josep ;
Muneretto, Claudio ;
Valgimigli, Marco ;
Achenbach, Stephan ;
Bax, Jeroen J. ;
Neumann, Franz-Josef ;
Sechtem, Udo ;
Banning, Adrian Paul ;
Bonaros, Nikolaos ;
Bueno, Hector ;
Bugiardini, Raffaele ;
Chieffo, Alaide ;
Crea, Filippo ;
Czerny, Martin ;
Delgado, Victoria ;
Dendale, Paul .
EUROPEAN HEART JOURNAL, 2020, 41 (03) :407-477
[10]  
Lin Eugene, 2009, J Cardiovasc Comput Tomogr, V3, P403, DOI 10.1016/j.jcct.2009.07.003