Development and evaluation of a personal cascade impactor sampler (PCIS)

被引:181
作者
Misra, C
Singh, M
Shen, S
Sioutas, C
Hall, PA
机构
[1] Univ So Calif, Dept Civil & Environm Engn, Los Angeles, CA 90089 USA
[2] SKC Inc, Eighty Four, PA 15330 USA
关键词
personal sampler; particulate matter (PM); battery-operated light pump; impaction substrates; particle bounce;
D O I
10.1016/S0021-8502(02)00055-1
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
This paper presents development and evaluation of a personal sampler for particulate matter that allows separation of airborne particles by size. The Personal Cascade Impactor Sampler (PCIS) is a miniaturized cascade impactor, consisting of four impaction stages, followed by an after-filter. Particles are separated in the following aerodynamic particle diameter ranges: < 0.25, 0.25-0.5, 0.5-1.0, 1.0-2.5 and 2.5-10 μm. The PCIS operates at a flow rate of 9 LPM using a very high efficiency, battery-operated light pump at a pressure drop of 11 in H2O (2.7 kPa). PTFE (Teflon), quartz and aluminum substrates were chosen for characterization of the PCIS. Laboratory tests conducted with monodisperse polystyrene latex (PSL) particles as well as polydisperse ammonium sulfate and ammonium nitrate aerosols corroborated the cutpoints. Our experimental characterization identified 2.5 cm Teflon filters as ideal impaction substrates because they result in high collection efficiency of particles above the cutpoint of each stage without the use of adhesive coatings, do not collect excessively particles below the cutpoint (a problem encountered with the use of quartz substrates) and because of their ability to be used for gravimetric analysis. Particle loading tests indicated that the PCIS stages could collect up to 3.16 and 0.7 mg of fine and coarse PM, respectively, without any loss in the collection efficiency, which would have been a result of particle bounce. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1027 / 1047
页数:21
相关论文
共 32 条
[1]   Relative contribution of outdoor and indoor particle sources to indoor concentrations [J].
Abt, E ;
Suh, HH ;
Catalano, P ;
Koutrakis, P .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2000, 34 (17) :3579-3587
[2]   MEASUREMENT OF RESPIRATORY MORBIDITY IN GENERAL-PRACTICE IN THE UNITED-KINGDOM DURING THE ACID TRANSPORT EVENT OF JANUARY 1985 [J].
AYRES, J ;
FLEMING, D ;
WILLIAMS, M ;
MCINNES, G .
ENVIRONMENTAL HEALTH PERSPECTIVES, 1989, 79 :83-88
[3]   ASTHMA ATTACK PERIODICITY - A STUDY OF HOSPITAL EMERGENCY VISITS IN VANCOUVER [J].
BATES, DV ;
BAKERANDERSON, M ;
SIZTO, R .
ENVIRONMENTAL RESEARCH, 1990, 51 (01) :51-70
[4]   THE ONTARIO AIR-POLLUTION STUDY - IDENTIFICATION OF THE CAUSATIVE AGENT [J].
BATES, DV ;
SIZTO, R .
ENVIRONMENTAL HEALTH PERSPECTIVES, 1989, 79 :69-72
[5]  
CLAYTON CA, 1993, J EXPO ANAL ENV EPID, V3, P227
[6]  
DOCKERY DW, 1993, AM REV RESPIR DIS, V14, pA633
[7]   Bimodal character of accumulation mode aerosol mass distributions in Southern California [J].
Hering, S ;
Eldering, A ;
Seinfeld, JH .
ATMOSPHERIC ENVIRONMENT, 1997, 31 (01) :1-11
[8]  
Hinds W.C., 1982, Aerosol Technology
[9]   Indoor/outdoor relationships of particulate matter in domestic homes with roadside, urban and rural locations [J].
Jones, NC ;
Thornton, CA ;
Mark, D ;
Harrison, RM .
ATMOSPHERIC ENVIRONMENT, 2000, 34 (16) :2603-2612