Energy Based Correlation Method for Location of Partial Discharge in Transformer Winding

被引:1
|
作者
Jeyabalan, V. [1 ]
Usa, S. [1 ]
机构
[1] Anna Univ, CEG, DEEE, Div High Voltage Engn, Madras 600025, Tamil Nadu, India
关键词
Transformers; Insulation failure; Partial Discharge location; Energy; Correlation method; time domain correlation; BREAKDOWN;
D O I
10.4316/aece.2009.01008
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Partial discharge (PD) is the major source of insulation failure in power transformer. When transformers are subjected to electrical stress during operation, PD can occur. PD identification is an important diagnostic tool for the reliable operation of transformers. The PD signal detection and location is one of the main challenges for system utilities and equipment manufacturers. In this paper energy based correlation method is proposed for locating the source of PD for different pulse durations. Simulation and experiment are performed on lumped physical layer winding to prove the feasibility of the method and also verified with distributed model of 22kV prototype interleaved winding.
引用
收藏
页码:46 / 51
页数:6
相关论文
共 50 条
  • [31] The Influence of Cavity Size and Location Within Insulation Paper on the Partial Discharge Activities
    Roslan, Muhammad Hakirin
    Azis, Norhafiz
    Ab Kadir, Mohd Zainal Abidin
    Jasni, Jasronita
    Yousof, Mohd Fairouz Mohd
    PERTANIKA JOURNAL OF SCIENCE AND TECHNOLOGY, 2023, 31 (06): : 2915 - 2930
  • [32] On-line three-phase differential partial discharge localization in transformer bushings
    Meyer, Hans Kristian Hygen
    Eberg, Espen
    Lundgaard, Lars
    2021 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2021, : 80 - 83
  • [33] Insulation failure detection in transformer winding using cross-correlation technique with ANN and k-NN regression method during impulse test
    Rahmatian, M.
    Vahidi, B.
    Ghanizadeh, A. J.
    Gharehpetian, G. B.
    Alehosseini, H. A.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2013, 53 : 209 - 218
  • [34] WHAT MEDIUM AND HIGH VOLTAGE STATOR WINDING PARTIAL DISCHARGE TESTING CAN - AND CAN NOT - TELL YOU
    Stone, Greg
    Sedding, Howard
    Veerkamp, William
    2021 IEEE IAS PETROLEUM AND CHEMICAL INDUSTRY TECHNICAL CONFERENCE (PCIC), 2021, : 293 - 301
  • [35] A PDE-based partial discharge simulator
    Villa, Andrea
    Barbieri, Luca
    Gondola, Marco
    Leon-Garzon, Andres R.
    Malgesini, Roberto
    JOURNAL OF COMPUTATIONAL PHYSICS, 2017, 345 : 687 - 705
  • [36] UHF partial discharge localisation method in substation based on dimension-reduced RSSI fingerprint
    Li, Zhen
    Luo, Lingen
    Sheng, Gehao
    Liu, Yadong
    Jiang, Xiuchen
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2018, 12 (02) : 398 - 405
  • [37] A New Cross-Correlation Algorithm Based on Distance for Improving Localization Accuracy of Partial Discharge in Cables Lines
    Rao, Xianjie
    Zhou, Kai
    Li, Yuan
    Zhu, Guangya
    Meng, Pengfei
    ENERGIES, 2020, 13 (17)
  • [38] A Design Method of Partially Interleaved Winding Structure With Low Leakage Inductance for Planar Transformer Application
    Zhou, Xuetong
    Tian, Yufei
    Quan, Yuhua
    Zhang, Xuefei
    Liu, Tiantian
    Feng, Junhong
    Wang, Da
    Cheng, Xinhong
    Zheng, Li
    Yu, Yuehui
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2023, 38 (05) : 6366 - 6379
  • [39] Estimation of Charge, Energy and Polarity of Noisy Partial Discharge Pulses
    Mor, A. Rodrigo
    Heredia, L. C. Castro
    Munoz, F. A.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2017, 24 (04) : 2511 - 2521
  • [40] Partial Discharge Localization in Insulated Switchgears by Eigenfunction Expansion Method
    D'Antona, Gabriele
    Perfetto, Luca
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2019, 68 (05) : 1294 - 1301