Energy Based Correlation Method for Location of Partial Discharge in Transformer Winding

被引:1
|
作者
Jeyabalan, V. [1 ]
Usa, S. [1 ]
机构
[1] Anna Univ, CEG, DEEE, Div High Voltage Engn, Madras 600025, Tamil Nadu, India
关键词
Transformers; Insulation failure; Partial Discharge location; Energy; Correlation method; time domain correlation; BREAKDOWN;
D O I
10.4316/aece.2009.01008
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Partial discharge (PD) is the major source of insulation failure in power transformer. When transformers are subjected to electrical stress during operation, PD can occur. PD identification is an important diagnostic tool for the reliable operation of transformers. The PD signal detection and location is one of the main challenges for system utilities and equipment manufacturers. In this paper energy based correlation method is proposed for locating the source of PD for different pulse durations. Simulation and experiment are performed on lumped physical layer winding to prove the feasibility of the method and also verified with distributed model of 22kV prototype interleaved winding.
引用
收藏
页码:46 / 51
页数:6
相关论文
共 50 条
  • [21] Review on Partial Discharge Characteristics of Bubble Impurity Phase in Transformer Oil
    Zhang N.
    Liu S.
    Hao J.
    Chen H.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2023, 38 (10): : 2757 - 2776
  • [22] Statistics based method for partial discharge identification in oil paper insulation systems
    Kunicki, Michal
    Cichon, Andrzej
    Nagi, Lukasz
    ELECTRIC POWER SYSTEMS RESEARCH, 2018, 163 : 559 - 571
  • [23] Partial Discharge and Breakdown Characteristics of Moving Transformer Oil Contaminated by Metallic Particles
    Pan, Cheng
    Tang, Ju
    Tao, Xiantao
    Zhang, Yongze
    Ma, Shouxiao
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2018, 25 (05) : 1774 - 1784
  • [24] Partial Discharge Measurement and Analysis of Transformer Under Oscillating Lightning Impulse Voltage
    Zhang, Xuanrui
    Guo, Ruochen
    Yang, Yun
    Hu, Yidan
    Zhang, Zhaoyu
    Li, Junhao
    Han, Xutao
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2022, 29 (06) : 2303 - 2311
  • [25] Partial Discharge and Breakdown Characteristics of Inverter-fed Motor Winding with Micro Cellular Coating
    Hikita, Masayuki
    Yanaze, Naoto
    Uchimura, Tomoki
    Kozako, Masahiro
    Tomizawa, Keiichi
    Ohya, Makoto
    2016 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (IEEE CEIDP), 2016, : 482 - 485
  • [26] A novel method to check the axial tilt instability of the rectangular winding of the amorphous alloy transformer
    Guo, Jian
    Fang, Shuhua
    Zhang, Ying
    Jin, Yamei
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2018, 13 (01) : 92 - 97
  • [27] Principal component and hierarchical cluster analyses as applied to transformer partial discharge data with particular reference to transformer condition monitoring
    Babnik, Tadeja
    Aggarwal, Raj K.
    Moore, Philip J.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2008, 23 (04) : 2008 - 2016
  • [28] A Harmonics Elimination Method Using a Three-Winding Transformer for HVDC Transmission Systems
    Yamashita, Ken-ichiro
    Kameda, Yoshiki
    Nishikata, Shoji
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2018, 54 (02) : 1645 - 1651
  • [29] A Circulating Power Suppression Structure for Three-Winding-Transformer-Based Converter
    Yan, Zhixing
    Tang, Ting
    Yu, Zehui
    Chen, Run
    Lai, Zhen
    Ying, Gengning
    Yang, Ningrui
    Zeng, Jun
    Liu, Junfeng
    Hu, Renjun
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2022, 37 (08) : 8800 - 8804
  • [30] Identification Winding Material of Distribution Transformer Based on Multi-Information Fusion
    Xiong, Hu
    Li, Jiayuan
    Xie, Xianming
    Xiang, Bin
    Jiang, Xiaoguang
    Zhu, Changchen
    Liu, Zhixiong
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2024, 34 (08)