Removal of PCBs from electrical equipment by the vacuum heating separation method (Part. 1) removal of low concentration PCBs from pole transformers
被引:0
|作者:
Kanbe, H
[1
]
Shibuya, M
[1
]
机构:
[1] Cent Res Inst Elect Power Ind, Tokyo 201, Japan
来源:
2001 POWER ENGINEERING SOCIETY SUMMER MEETING, VOLS 1-3, CONFERENCE PROCEEDINGS
|
2001年
关键词:
PCBs;
polychlorinated biphenyl;
pole transformer;
transformer;
vacuum heating separation method;
vacuum thermal recycling;
VTR;
Electrical Equipment;
D O I:
暂无
中图分类号:
TE [石油、天然气工业];
TK [能源与动力工程];
学科分类号:
0807 ;
0820 ;
摘要:
There are currently about four million pole transformers that were used for electric power supply throughout Japan that contain trace amounts (50mg-PCB/kg-insulation oil or less) of PCBs. The prompt creation of a safe disposal method to render this PCBs harmless is required. We performed tests on the removal of PCBs by a low temperature vacuum heating method, using pole transformers that had actually been placed in service and that contain low concentrations of PCBs. The results of these tests confirmed that under standard applicable conditions of a vacuum of 0.05 torr or less, a heating temperature of 200degreesC and a vacuum holding period of 10 hours, the residual quantity of PCBs in impregnated transformer parts can be almost reduced to less than the quantitative determination lower limit of 0.05mg-PCB/kg-material. The test results also clearly showed that the test equipment and the disposal method do not have a harmful effect on the environment.