Non-invasive cardiac output assessment during moderate exercise:: pulse contour compared with CO2 rebreathing

被引:27
|
作者
Houtman, S [1 ]
Oeseburg, B [1 ]
Hopman, MTE [1 ]
机构
[1] Univ Nijmegen, Dept Physiol 237, NL-6525 EZ Nijmegen, Netherlands
来源
CLINICAL PHYSIOLOGY | 1999年 / 19卷 / 03期
关键词
daily life activity; Finapres; Portapres; modelflow;
D O I
10.1046/j.1365-2281.1999.00166.x
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The arterial pulse contour method called Modelflow 2.1 calculates stroke volume continuously, beat to beat, from the non-invasive blood pressure signal measured by Finapres or Portapres. Portapres is the portable version of Finapres. The purpose of this study was to compare cardiac output (CO) calculated using Modelflow 2.1 (COmf) with CO obtained by the CO2 rebreathing method (COre) during steady state at moderate exercise levels. Twelve subjects visited the laboratory twice and performed submaximal exercise on a bicycle ergometer at 20%, 40% and 60% of their individual peak power output (POpeak) The averaged correlation between COmf and COre gives an r-value of 0.69, whereas the slope and intercept of the regression line were 1.06 and 1.65 respectively. The averaged difference between COmf and COre was 2.27 +/- 3.91 min(-1) (mean +/- standard deviation). However, the test-retest difference between COmf and COre was 2.5 +/- 3.1 and 0.5 +/- 1.3 l min(-1) respectively. These results suggest that Modelflow 2.1 is not an accurate method for estimating CO from non-invasive blood pressure data collected by Portapres during exercise at up to 60% of the individual POpeak corresponding with daily life activity.
引用
收藏
页码:230 / 237
页数:8
相关论文
共 50 条
  • [21] CONSISTENCY OF CARBON-DIOXIDE REBREATHING AS A NON-INVASIVE METHOD TO DETERMINE EXERCISE CARDIAC-OUTPUT
    KNOWLTON, RG
    ADAMS, GE
    ERGONOMICS, 1974, 17 (02) : 241 - 248
  • [22] The effect of haemodynamic and peripheral vascular variability on cardiac output monitoring: thermodilution and non-invasive pulse contour cardiac output during cardiothoracic surgery
    Truijen, J.
    Westerhof, B. E.
    Kim, Y-S.
    Stok, W. J.
    de Mol, B. A.
    Preckel, B.
    Hollmann, M. W.
    van Lieshout, J. J.
    ANAESTHESIA, 2018, 73 (12) : 1489 - 1499
  • [23] Cardiac output monitoring with thermodilution pulse-contour analysis vs. non-invasive pulse-contour analysis
    Boisson, M.
    Poignard, M. E.
    Pontier, B.
    Mimoz, O.
    Debaene, B.
    Frasca, D.
    ANAESTHESIA, 2019, 74 (06) : 735 - 740
  • [24] Non-invasive cardiac output evaluation during progressive exercise test
    Richard, R
    Lonsdorfer-Wolf, E
    Charloux, A
    Oswald-Mammoser, M
    Mettauer, B
    Lampert, E
    Lonsdorfer, J
    PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 2000, 440 (06): : R268 - R268
  • [25] Non-invasive assessment of cardiac output during mechanical ventilation - a novel approach using an inert gas rebreathing method
    Nickl, Werner
    Bugaj, Till
    Mondritzki, Thomas
    Kuhlebrock, Kathrin
    Dinh, Winfried
    Krahn, Thomas
    Sohler, Florian
    Truebel, Hubert
    BIOMEDIZINISCHE TECHNIK, 2011, 56 (03): : 147 - 151
  • [26] Do rebreathing manoeuvres for non-invasive measurement of cardiac output during maximum exercise test alter the main cardiopulmonary parameters?
    Vignati, Carlo
    Morosin, Marco
    Fusini, Laura
    Pezzuto, Beatrice
    Spadafora, Emanuele
    De Martino, Fabiana
    Salvioni, Elisabetta
    Rovai, Sara
    Filardi, Pasquale P.
    Sinagra, Gianfranco
    Agostoni, Piergiuseppe
    EUROPEAN JOURNAL OF PREVENTIVE CARDIOLOGY, 2019, 26 (15) : 1616 - 1622
  • [27] Pulse contour cardiac output derived from non-invasive arterial pressure in cardiovascular disease
    Bogert, L. W. J.
    Wesseling, K. H.
    Schraa, O.
    Van Lieshout, E. J.
    de Mol, B. A. J. M.
    van Goudoever, J.
    Westerhof, B. E.
    van Lieshout, J. J.
    ANAESTHESIA, 2010, 65 (11) : 1119 - 1125
  • [28] NONINVASIVE CARDIAC OUTPUT MONITORING DURING EXERCISE TESTING: NEXFIN PULSE CONTOUR ANALYSIS COMPARED TO AN INERT GAS REBREATHING METHOD AND RESPIRED GAS ANALYSIS
    Bartels, Sebastiaan A.
    Stok, Wim J.
    Bezemer, Rick
    Boksem, Remco J.
    van Goudoever, Jeroen
    Cherpanath, Thomas G. V.
    van Lieshout, Johannes J.
    Westerhof, Berend E.
    Karemaker, John M.
    Ince, Can
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2011, 25 (05) : 315 - 321
  • [29] Noninvasive cardiac output monitoring during exercise testing: Nexfin pulse contour analysis compared to an inert gas rebreathing method and respired gas analysis
    Sebastiaan A. Bartels
    Wim J. Stok
    Rick Bezemer
    Remco J. Boksem
    Jeroen van Goudoever
    Thomas G. V. Cherpanath
    Johannes J. van Lieshout
    Berend E. Westerhof
    John M. Karemaker
    Can Ince
    Journal of Clinical Monitoring and Computing, 2011, 25 : 315 - 321
  • [30] Non-invasive assessment of cardiac output in children
    Richardson, JR
    Ferguson, J
    Hiscox, J
    Rawles, J
    JOURNAL OF ACCIDENT & EMERGENCY MEDICINE, 1998, 15 (05): : 304 - 307