Phosphorus flame retardants in indoor dust and their relation to asthma and allergies of

被引:184
作者
Araki, A. [1 ,2 ]
Saito, I. [3 ]
Kanazawa, A. [2 ]
Morimoto, K. [4 ]
Nakayama, K. [4 ]
Shibata, E. [5 ]
Tanaka, M. [6 ]
Takigawa, T. [7 ]
Yoshimura, T. [8 ]
Chikara, H. [8 ]
Saijo, Y. [9 ]
Kishi, R. [1 ]
机构
[1] Hokkaido Univ, Ctr Environm & Hlth Sci, Sapporo, Hokkaido 0600812, Japan
[2] Hokkaido Univ, Grad Sch Med, Dept Publ Hlth Sci, Sapporo, Hokkaido 0600812, Japan
[3] Tokyo Metropolitan Inst Publ Hlth, Dept Environm Hlth & Toxicol, Div Environm Hlth, Tokyo 1690073, Japan
[4] Osaka Univ, Grad Sch Med, Suita, Osaka, Japan
[5] Aichi Med Univ, Sch Med, Nagakute, Aichi, Japan
[6] Fukushima Med Univ, Fukushima, Japan
[7] Okayama Univ, Grad Sch Med Dent & Pharmaceut Sci, Okayama 7008530, Japan
[8] Fukuoka Inst Hlth & Environm Sci, Dazaifu, Japan
[9] Asahikawa Med Univ, Asahikawa, Hokkaido, Japan
关键词
Phosphorus flame retardants; Organophosphate triesters; Indoor dust; Dwellings; Asthma; Allergy; SEMIVOLATILE ORGANIC-COMPOUNDS; IN-HOUSE DUST; HUMAN EXPOSURE; PHTHALATE EXPOSURE; SYMPTOMS; ASSOCIATION; ORGANOPHOSPHATE; ENVIRONMENTS; CONTAMINANTS; PREVALENCE;
D O I
10.1111/ina.12054
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Organophosphate esters are used as additives in flame retardants and plasticizers, and they are ubiquitous in the indoor environment. Phosphorus flame retardants (PFRs) are present in residential dust, but few epidemiological studies have assessed their impact on human health. We measured the levels of 11 PFRs in indoor floor dust and multi-surface dust in 182 single-family dwellings in Japan. We evaluated their correlations with asthma and allergies of the inhabitants. Tris(2-butoxyethyl) phosphate was detected in all samples (median value: 580g/g in floor dust, 111g/g in multi-surface dust). Tris(2-chloro-iso-propyl) phosphate (TCIPP) was detected at 8.69g/g in floor dust and 25.8g/g in multi-surface dust. After adjustment for potential confounders, significant associations were found between the prevalence of atopic dermatitis and the presence of TCIPP and tris(1,3-dichloro-2-propyl) phosphate in floor dust [per log(10)-unit, odds ratio (OR): 2.43 and 1.84, respectively]. Tributyl phosphate was significantly associated with the prevalence of asthma (OR: 2.85 in floor dust, 5.34 in multi-surface dust) and allergic rhinitis (OR: 2.55 in multi-surface dust). PFR levels in Japan were high compared with values reported previously for Europe, Asia-Pacific, and the USA. Higher levels of PFRs in house dust were related to the inhabitants' health status.
引用
收藏
页码:3 / 15
页数:13
相关论文
共 52 条
  • [1] Emission of phthalates from PVC and other materials
    Afshari, A
    Gunnarsen, L
    Clausen, PA
    Hansen, V
    [J]. INDOOR AIR, 2004, 14 (02) : 120 - 128
  • [2] Assessment of human exposure to indoor organic contaminants via dust ingestion in Pakistan
    Ali, N.
    Van den Eede, N.
    Dirtu, A. C.
    Neels, H.
    Covaci, A.
    [J]. INDOOR AIR, 2012, 22 (03) : 200 - 211
  • [3] Occurrence of alternative flame retardants in indoor dust from New Zealand: Indoor sources and human exposure assessment
    Ali, Nadeem
    Dirtu, Alin C.
    Van den Eede, Nele
    Goosey, Emma
    Harrad, Stuart
    Neels, Hugo
    't Mannetje, Andrea
    Coakley, Jonathan
    Douwes, Jeroen
    Covaci, Adrian
    [J]. CHEMOSPHERE, 2012, 88 (11) : 1276 - 1282
  • [4] [Anonymous], 1998, ENV HLTH CRIT
  • [5] Diffusive sampling and measurement of microbial volatile organic compounds in indoor air
    Araki, A.
    Eitaki, Y.
    Kawai, T.
    Kanazawa, A.
    Takeda, M.
    Kishi, R.
    [J]. INDOOR AIR, 2009, 19 (05) : 421 - 432
  • [6] The relationship between exposure to microbial volatile organic compound and allergy prevalence in single-family homes
    Araki, Atsuko
    Kanazawa, Ayako
    Kawai, Toshio
    Eitaki, Yoko
    Morimoto, Kanehisa
    Nakayama, Kunio
    Shibata, Eiji
    Tanaka, Masatoshi
    Takigawa, Tomoko
    Yoshimura, Takesumi
    Chikara, Hisao
    Saijo, Yasuaki
    Kishi, Reiko
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2012, 423 : 18 - 26
  • [7] Relationship between selected indoor volatile organic compounds, so-called microbial VOC, and the prevalence of mucous membrane symptoms in single family homes
    Araki, Atsuko
    Kawai, Toshio
    Eitaki, Yoko
    Kanazawa, Ayako
    Morimoto, Kanehisa
    Nakayama, Kunio
    Shibata, Eiji
    Tanaka, Masatoshi
    Takigawa, Tomoko
    Yoshimura, Takesumi
    Chikara, Hisao
    Saijo, Yasuaki
    Kishi, Reiko
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2010, 408 (10) : 2208 - 2215
  • [8] Primary prevention of asthma and allergy
    Arshad, SH
    [J]. JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2005, 116 (01) : 3 - 14
  • [9] Organophosphate and phthalate esters in air and settled dust - a multi-location indoor study
    Bergh, C.
    Torgrip, R.
    Emenius, G.
    Ostman, C.
    [J]. INDOOR AIR, 2011, 21 (01) : 67 - 76
  • [10] A novel abbreviation standard for organobromine, organochlorine and organophosphorus flame retardants and some characteristics of the chemicals
    Bergman, Ake
    Ryden, Andreas
    Law, Robin J.
    de Boer, Jacob
    Covaci, Adrian
    Alaee, Mehran
    Birnbaum, Linda
    Petreas, Myrto
    Rose, Martin
    Sakai, Shinichi
    Van den Eede, Nele
    van der Veen, Ike
    [J]. ENVIRONMENT INTERNATIONAL, 2012, 49 : 57 - 82