Hydrodynamic and mass transfer characteristics of ejector loop reactors

被引:55
作者
Havelka, P
Linek, V [1 ]
Sinkule, J
Zahradník, J
Fialová, M
机构
[1] Inst Chem Technol, Dept Chem Engn, Prague 16628 6, Czech Republic
[2] Acad Sci Czech Republ, Inst Chem Proc Fundamentals, Prague 16502 6, Czech Republic
[3] Res Inst Organ Synth, Dept Prod Engn, CS-53218 Pardubice, Czech Republic
关键词
aeration; ejector; absorption; mass transfer; mixing; dispersion gas-liquid;
D O I
10.1016/S0009-2509(99)00343-7
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Volumetric liquid-side mass transfer coefficient k(L)a was measured in the upflow ejector (with and without swirl) and in the cocurrent elector-distributor bubble column as well as gas and liquid phase backmixing in the column. Water and 0.3 M aqueous solution of Na2SO4 were used to simulate coalescent and non-coalescent batches. Different methods were used to measure k(L)a: dynamic pressure-step (DPM), steady-state physical (SPM),classic sulfite (CSM) and steady-state sulfite method (SSM). Pure oxygen and air were used as the gas phase. Large intensity of liquid mixing in the column caused by the jet with high kinetic energy was confirmed. Gas backmixing in the coalescent batch was well described by the axial dispersion model while gas backmixing in the non-coalescent batch was successfully described by the model of two parallel series of four perfect mixers with backflow, where the respective branches corresponded to the small and large bubbles present in the dispersion, was therefore proposed. Experimental data indicated lower extent of mixing in large bubbles as compared with the smaller ones. Installation of a swirl significantly: influenced bubble sizes in the non-coalescent batch. Values of k(L)a(e3) in the ejector with a swirl were lower than those for the ejector without a swirl, both in the coalescent and non-coalescent batches. The coefficient k(L)a(col) in the column was well correlated with gas holdup for the coalescent batch. A good agreement was observed between the data obtained by DPM and SPM methods. In the non-coalescent batch the chemical methods were used as the DPM method failed being limited by the response rate of oxygen probes used. Both the methods (CSM and SSF) yielded similar values of k(L)a(col) in the case of oxygen absorption. Absorption of air yielded significantly lower values k(L)a(col) (by factor of two) when a model of a single series of four perfect mixers was used for description of the gas flow in the reactor. The model of two parallel series of four perfect mixers with backflow was therefore used, taking into account particular contributions of small and large bubbles to the overall mass transfer in the column. It has been shown that decisive part of oxygen has been absorbed from the small bubbles. (C) 1999 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:535 / 549
页数:15
相关论文
共 38 条
[1]  
[Anonymous], 1956, T AM SOC CIV ENG, DOI DOI 10.1061/TACEAT.0007317
[2]  
Bando Y., 1990, INT CHEM ENG, V30, P729
[3]   HYDRODYNAMICS AND MASS-TRANSFER CHARACTERISTICS OF A LOOP-VENTURI REACTOR WITH A DOWNFLOW LIQUID JET EJECTOR [J].
CRAMERS, PHMR ;
BEENACKERS, AACM ;
VANDIERENDONCK, LL .
CHEMICAL ENGINEERING SCIENCE, 1992, 47 (13-14) :3557-3564
[4]   HYDRODYNAMICS AND LOCAL MASS-TRANSFER CHARACTERISTICS OF GAS-LIQUID EJECTORS [J].
CRAMERS, PHMR ;
SMIT, L ;
LEUTERITZ, GM ;
VANDIERENDONCK, LL ;
BEENACKERS, AACM .
CHEMICAL ENGINEERING JOURNAL AND THE BIOCHEMICAL ENGINEERING JOURNAL, 1993, 53 (01) :67-73
[5]   JET BREAKUP AND MIXING THROAT LENGTHS FOR LIQUID JET GAS PUMP [J].
CUNNINGHAM, RG ;
DOPKIN, RJ .
JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 1974, 96 (03) :216-226
[6]   MASS-TRANSFER IN JET LOOP REACTORS [J].
DIRIX, CAMC ;
VANDERWIELE, K .
CHEMICAL ENGINEERING SCIENCE, 1990, 45 (08) :2333-2340
[7]   Detailed modeling of the chemisorption of CO2 into NaOH in a bubble column [J].
Fleischer, C ;
Becker, S ;
Eigenberger, G .
CHEMICAL ENGINEERING SCIENCE, 1996, 51 (10) :1715-1724
[8]   Effect of the ejector configuration on the gas suction rate and gas hold up in ejector loop reactors [J].
Havelka, P ;
Linek, V ;
Sinkule, J ;
Zahradnik, J ;
Fialova, M .
CHEMICAL ENGINEERING SCIENCE, 1997, 52 (11) :1701-1713
[9]   INFLUENCE OF VERY SMALL BUBBLES ON THE DYNAMIC KLA MEASUREMENT IN VISCOUS GAS-LIQUID SYSTEMS [J].
HEIJNEN, JJ ;
RIET, KV ;
WOLTHUIS, AJ .
BIOTECHNOLOGY AND BIOENGINEERING, 1980, 22 (09) :1945-1956
[10]  
Henzler H., 1981, VERFAHRENSTECHNIK, V15, P738