Inter and intra-rater reliability of mobile device goniometer in measuring lumbar flexion range of motion

被引:18
|
作者
Bedekar, Nilima [1 ]
Suryawanshi, Mayuri [1 ]
Rairikar, Savita [1 ]
Sancheti, Parag [2 ]
Shyam, Ashok [2 ]
机构
[1] Sancheti Inst, Coll Physiotherapy, Pune 411005, Maharashtra, India
[2] Sancheti Inst Orthopaed & Rehabil, Pune, Maharashtra, India
关键词
Reliability; mobile device; iTune goniometer; range of motion; SPINE FLEXION; EXTENSION; MOVEMENT; VALIDITY; SCHOBER;
D O I
10.3233/BMR-130431
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BACKGROUND: Evaluation of range of motion (ROM) is integral part of assessment of musculoskeletal system. This is required in health fitness and pathological conditions; also it is used as an objective outcome measure. Several methods are described to check spinal flexion range of motion. Different methods for measuring spine ranges have their advantages and disadvantages. Hence, a new device was introduced in this study using the method of dual inclinometer to measure lumbar spine flexion range of motion (ROM). OBJECTIVES: To determine Intra and Inter-rater reliability of mobile device goniometer in measuring lumbar flexion range of motion. METHOD: iPod mobile device with goniometer software was used. The part being measure i.e the back of the subject was suitably exposed. Subject was standing with feet shoulder width apart. Spinous process of second sacral vertebra S2 and T12 were located, these were used as the reference points and readings were taken. Three readings were taken for each: inter-rater reliability as well as the intra-rater reliability. Sufficient rest was given between each flexion movement. RESULTS: Intra-rater reliability using ICC was r = 0.920 and inter-rater r = 0.812 at CI 95%. Validity r = 0.95. CONCLUSION: Mobile device goniometer has high intra-rater reliability. The inter-rater reliability was moderate. This device can be used to assess range of motion of spine flexion, representing uni-planar movement.
引用
收藏
页码:161 / 166
页数:6
相关论文
共 50 条
  • [41] Intra- and inter-rater reliability of goniometric finger range of motion using a written protocol
    Nakai, Takuya
    Amano, Satoru
    Murao, Chikako
    Taguchi, Haruki
    Takahashi, Kayoko
    ARCHIVES OF PHYSIOTHERAPY, 2024, 14 (01) : 83 - 88
  • [42] Intra- and inter-rater reliability of a modified measure of hand behind back range of motion
    van den Dolder, Paul A.
    Ferreira, Paulo H.
    Refshauge, Kathryn
    MANUAL THERAPY, 2014, 19 (01) : 72 - 76
  • [43] Inter-and intra-rater reliability of the B. Lindmark Motor Assessment
    Kierkegaard, Marie
    Tollback, Anna
    EUROPEAN JOURNAL OF PHYSIOTHERAPY, 2005, 7 (01) : 2 - 6
  • [44] Inter- and intra-rater reliability of digitally captured images of plate waste
    Navarro, Daniela Abigail
    Singer, Pierre
    Leibovitz, Eyal
    Krause, Ilan
    Boaz, Mona
    NUTRITION & DIETETICS, 2014, 71 (04) : 284 - 288
  • [45] Inter- and intra-rater reliability of the manual handling component of the WorkHab Functional Capacity Evaluation
    James, Carole
    Mackenzie, Lynette
    Capra, Mike
    DISABILITY AND REHABILITATION, 2011, 33 (19-20) : 1797 - 1804
  • [46] Inter-rater reliability, intra-rater reliability and internal consistency of the Brisbane Evidence-Based Language Test
    Rohde, Alexia
    McCracken, Molly
    Worrall, Linda
    Farrell, Anna
    O'Halloran, Robyn
    Godecke, Erin
    David, Michael
    Doi, Suhail A.
    DISABILITY AND REHABILITATION, 2022, 44 (04) : 637 - 645
  • [47] Inter-Rater Reliability and Intra-Rater Reliability of Assessing the 2-Minute Push-Up Test
    Fielitz, Lynn
    Coelho, Jeffrey
    Horne, Thomas
    Brechue, William
    MILITARY MEDICINE, 2016, 181 (02) : 167 - 172
  • [48] Evaluation of the inter-rater and intra-rater reliability of a protocol for the measurement of foot-transmitted vibration
    Vance, Brandon
    Goggins, Katie A.
    Godwin, Alison
    Oddson, Bruce E.
    Eger, Tammy R.
    THEORETICAL ISSUES IN ERGONOMICS SCIENCE, 2021, 22 (02) : 219 - 236
  • [49] Test-Retest, Inter-Rater and Intra-Rater Reliability for Spatiotemporal Gait Parameters Using SANE (an eaSy gAit aNalysis systEm) as Measuring Instrument
    Chaparro-Rico, Betsy D. M.
    Cafolla, Daniele
    APPLIED SCIENCES-BASEL, 2020, 10 (17):
  • [50] Inter-rater and Intra-rater Reliability in the Radiographic Diagnosis of Growth Arrest in Paediatric Physeal Fractures
    Nicole Banting
    Emily K. Schaeffer
    Jeffrey Bone
    Eva Habib
    Nikki Hooper
    Christopher W. Reilly
    Anthony Cooper
    Kishore Mulpuri
    Indian Journal of Orthopaedics, 2021, 55 : 445 - 451