Inter and intra-rater reliability of mobile device goniometer in measuring lumbar flexion range of motion

被引:18
|
作者
Bedekar, Nilima [1 ]
Suryawanshi, Mayuri [1 ]
Rairikar, Savita [1 ]
Sancheti, Parag [2 ]
Shyam, Ashok [2 ]
机构
[1] Sancheti Inst, Coll Physiotherapy, Pune 411005, Maharashtra, India
[2] Sancheti Inst Orthopaed & Rehabil, Pune, Maharashtra, India
关键词
Reliability; mobile device; iTune goniometer; range of motion; SPINE FLEXION; EXTENSION; MOVEMENT; VALIDITY; SCHOBER;
D O I
10.3233/BMR-130431
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BACKGROUND: Evaluation of range of motion (ROM) is integral part of assessment of musculoskeletal system. This is required in health fitness and pathological conditions; also it is used as an objective outcome measure. Several methods are described to check spinal flexion range of motion. Different methods for measuring spine ranges have their advantages and disadvantages. Hence, a new device was introduced in this study using the method of dual inclinometer to measure lumbar spine flexion range of motion (ROM). OBJECTIVES: To determine Intra and Inter-rater reliability of mobile device goniometer in measuring lumbar flexion range of motion. METHOD: iPod mobile device with goniometer software was used. The part being measure i.e the back of the subject was suitably exposed. Subject was standing with feet shoulder width apart. Spinous process of second sacral vertebra S2 and T12 were located, these were used as the reference points and readings were taken. Three readings were taken for each: inter-rater reliability as well as the intra-rater reliability. Sufficient rest was given between each flexion movement. RESULTS: Intra-rater reliability using ICC was r = 0.920 and inter-rater r = 0.812 at CI 95%. Validity r = 0.95. CONCLUSION: Mobile device goniometer has high intra-rater reliability. The inter-rater reliability was moderate. This device can be used to assess range of motion of spine flexion, representing uni-planar movement.
引用
收藏
页码:161 / 166
页数:6
相关论文
共 50 条
  • [31] Inter- and intra-rater reliability in fibroptic endoscopic evaluation of swallowing
    Tohara, H.
    Nakane, A.
    Murata, S.
    Mikushi, S.
    Ouchi, Y.
    Wakasugi, Y.
    Takashima, M.
    Chiba, Y.
    Uematsu, H.
    JOURNAL OF ORAL REHABILITATION, 2010, 37 (12) : 884 - 891
  • [32] Inter- and Intra-Rater Reliability of Neck Circumference Measurements in Children
    LaBerge, Robert C.
    Vaccani, Jean Philippe
    Gow, Robert M.
    Gaboury, Isabelle
    Hoey, Lynda
    Katz, Sherri L.
    PEDIATRIC PULMONOLOGY, 2009, 44 (01) : 64 - 69
  • [33] Inter- and Intra-Rater Reliability of the Visual Vertical in Subacute Stroke
    Piscicelli, Celine
    Barra, Julien
    Davoine, Patrice
    Chrispin, Anne
    Nadeau, Sylvie
    Perennou, Dominic
    STROKE, 2015, 46 (07) : 1979 - 1983
  • [34] Inter- and intra-rater reliability of carpal tunnel volume measurement
    Anderson, Drew A.
    Miller, Mackenzie J.
    Agur, Anne M.
    Oliver, Michele L.
    Gordon, Karen D.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING-IMAGING AND VISUALIZATION, 2022, 10 (02) : 211 - 216
  • [35] Intra-rater and inter-rater reliability of cervical active range of movement in young asymptomatic adults using inertial sensors
    Anoro-Hervera, Alejandro
    Lafuente-Perez, Adrian
    Navarro-Fernandez, Gonzalo
    Munoz-Garcia, Daniel
    Lerma-Lara, Sergio
    Beltran-Alacreu, Hector
    EXPERT REVIEW OF MEDICAL DEVICES, 2019, 16 (12) : 1071 - 1077
  • [36] Inter-rater and intra-rater reliability of the current assessment model and tools for laparoscopic suturing
    Chin-Hung Wei
    Shih-Chiang Shen
    Yih-Cherng Duh
    Kuei‐Yen Tsai
    Hsin-An Chen
    Shih-Wei Huang
    Surgical Endoscopy, 2022, 36 : 6586 - 6591
  • [37] Intra-rater and inter-rater reliability of Surgimap Spine software for measuring spinal postural angles from digital photographs
    Nesma A. Helmya
    Mohsen M. El-Sayyadb
    Omaima M. Kattabeib
    Bulletin of Faculty of Physical Therapy, 2015, 20 (2) : 193 - 199
  • [38] INTER-RATER, INTRA-RATER, AND INTER-MACHINE RELIABILITY OF QUANTITATIVE ULTRASOUND MEASUREMENTS OF THE PATELLAR TENDON
    Gellhorn, Alfred C.
    Carlson, M. Jake
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2013, 39 (05) : 791 - 796
  • [39] Inter-rater and Intra-rater Reliability of the Chinese Version of the Action Research Arm Test in People With Stroke
    Zhao, Jiang-Li
    Chen, Pei-Ming
    Zhang, Tao
    Li, Hai
    Lin, Qiang
    Mao, Yu-Rong
    Huang, Dong-Feng
    FRONTIERS IN NEUROLOGY, 2019, 10
  • [40] The Modifed-Modifed Schober Test for range of motion assessment of lumbar flexion in patients with low back pain: A study of criterion validity, intra- and inter-rater reliability and minimum metrically detectable change
    Tousignant, M
    Poulin, L
    Marchand, S
    Viau, A
    Place, C
    DISABILITY AND REHABILITATION, 2005, 27 (10) : 553 - 559