Inter and intra-rater reliability of mobile device goniometer in measuring lumbar flexion range of motion

被引:18
|
作者
Bedekar, Nilima [1 ]
Suryawanshi, Mayuri [1 ]
Rairikar, Savita [1 ]
Sancheti, Parag [2 ]
Shyam, Ashok [2 ]
机构
[1] Sancheti Inst, Coll Physiotherapy, Pune 411005, Maharashtra, India
[2] Sancheti Inst Orthopaed & Rehabil, Pune, Maharashtra, India
关键词
Reliability; mobile device; iTune goniometer; range of motion; SPINE FLEXION; EXTENSION; MOVEMENT; VALIDITY; SCHOBER;
D O I
10.3233/BMR-130431
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BACKGROUND: Evaluation of range of motion (ROM) is integral part of assessment of musculoskeletal system. This is required in health fitness and pathological conditions; also it is used as an objective outcome measure. Several methods are described to check spinal flexion range of motion. Different methods for measuring spine ranges have their advantages and disadvantages. Hence, a new device was introduced in this study using the method of dual inclinometer to measure lumbar spine flexion range of motion (ROM). OBJECTIVES: To determine Intra and Inter-rater reliability of mobile device goniometer in measuring lumbar flexion range of motion. METHOD: iPod mobile device with goniometer software was used. The part being measure i.e the back of the subject was suitably exposed. Subject was standing with feet shoulder width apart. Spinous process of second sacral vertebra S2 and T12 were located, these were used as the reference points and readings were taken. Three readings were taken for each: inter-rater reliability as well as the intra-rater reliability. Sufficient rest was given between each flexion movement. RESULTS: Intra-rater reliability using ICC was r = 0.920 and inter-rater r = 0.812 at CI 95%. Validity r = 0.95. CONCLUSION: Mobile device goniometer has high intra-rater reliability. The inter-rater reliability was moderate. This device can be used to assess range of motion of spine flexion, representing uni-planar movement.
引用
收藏
页码:161 / 166
页数:6
相关论文
共 50 条
  • [21] Ultrasound Imaging Analysis of the Lumbar Multifidus Muscle Echo Intensity: Intra-Rater and Inter-Rater Reliability of a Novice and an Experienced Rater
    Fortin, Maryse
    Rosenstein, Brent
    Levesque, Jerome
    Nandlall, Neil
    MEDICINA-LITHUANIA, 2021, 57 (05):
  • [22] Measuring the quality of life in mild to very severe dementia: Testing the inter-rater and intra-rater reliability of the German version of the QUALIDEM
    Dichter, Martin Nikolaus
    Schwab, Christian G. G.
    Meyer, Gabriele
    Bartholomeyczik, Sabine
    Dortmann, Olga
    Halek, Margareta
    INTERNATIONAL PSYCHOGERIATRICS, 2014, 26 (05) : 825 - 836
  • [23] Intra-rater and inter-rater reliability of cranio cervical flexion test in symptomatic subjects of neck pain using pressure biofeedback
    Rajalaxmi, V.
    Kotteswari, S.
    Nisha, R. Nithya
    Nallathambi, Mohan
    BANGLADESH JOURNAL OF MEDICAL SCIENCE, 2023, 22 (03): : 617 - 622
  • [24] Inter-rater and Intra-rater Reliability of the Videofluoroscopic Dysphagia Scale with the Standardized Protocol
    Ingi Min
    Hyeonseong Woo
    Jae Yoon Kim
    Tae-Lim Kim
    Yookyung Lee
    Won Kee Chang
    Se Hee Jung
    Woo Hyung Lee
    Byung-Mo Oh
    Tai Ryoon Han
    Han Gil Seo
    Dysphagia, 2024, 39 : 43 - 51
  • [25] Intra-rater and inter-rater reliability of gait measurements with CODA mpx30 motion analysis system
    Maynard, V
    Bakheit, AMO
    Oldham, J
    Freeman, J
    GAIT & POSTURE, 2003, 17 (01) : 59 - 67
  • [26] Intra-rater and inter-rater reliability of six musculoskeletal preparticipatory screening tests
    Zumana, Nosipho
    Olivier, Benita
    Godlwana, Lonwabo
    Martin, Candice
    SOUTH AFRICAN JOURNAL OF PHYSIOTHERAPY, 2019, 75 (01)
  • [27] The inter-rater and intra-rater reliability of passive physiological accessory movement assessment of lumbar spine in novice manual therapists
    Deore, Mangesh
    May, Stephen
    JOURNAL OF BODYWORK AND MOVEMENT THERAPIES, 2012, 16 (03) : 289 - 293
  • [28] INTER AND INTRA-RATER RELIABILITY OF THE DROP VERTICAL JUMP (DVJ) ASSESSMENT
    Beyer, Emily B.
    Hale, Rena F.
    Hellem, Aaron R.
    Mumbleau, Allison M.
    Schilaty, Nathan D.
    Hewett, Timothy E.
    INTERNATIONAL JOURNAL OF SPORTS PHYSICAL THERAPY, 2020, 15 (05): : 770 - 775
  • [29] Concurrent validity and reliability of measuring range of motion during the cervical flexion rotation test with a novel digital goniometer
    Kerstin Luedtke
    Thomas Schoettker-Königer
    Toby Hall
    Christine Reimer
    Maike Grassold
    Petra Hasselhoff-Styhler
    Christian Neulinger
    Max Obrocki
    Philipp Przyhoda
    Axel Schäfer
    BMC Musculoskeletal Disorders, 21
  • [30] Concurrent validity and reliability of measuring range of motion during the cervical flexion rotation test with a novel digital goniometer
    Luedtke, Kerstin
    Schoettker-Koeniger, Thomas
    Hall, Toby
    Enns, Christine
    Grassold, Maike
    Hasselhoff-Styhler, Petra
    Neulinger, Christian
    Obrocki, Max
    Przyhoda, Philipp
    Schaefer, Axel
    BMC MUSCULOSKELETAL DISORDERS, 2020, 21 (01)