Inter and intra-rater reliability of mobile device goniometer in measuring lumbar flexion range of motion

被引:18
|
作者
Bedekar, Nilima [1 ]
Suryawanshi, Mayuri [1 ]
Rairikar, Savita [1 ]
Sancheti, Parag [2 ]
Shyam, Ashok [2 ]
机构
[1] Sancheti Inst, Coll Physiotherapy, Pune 411005, Maharashtra, India
[2] Sancheti Inst Orthopaed & Rehabil, Pune, Maharashtra, India
关键词
Reliability; mobile device; iTune goniometer; range of motion; SPINE FLEXION; EXTENSION; MOVEMENT; VALIDITY; SCHOBER;
D O I
10.3233/BMR-130431
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BACKGROUND: Evaluation of range of motion (ROM) is integral part of assessment of musculoskeletal system. This is required in health fitness and pathological conditions; also it is used as an objective outcome measure. Several methods are described to check spinal flexion range of motion. Different methods for measuring spine ranges have their advantages and disadvantages. Hence, a new device was introduced in this study using the method of dual inclinometer to measure lumbar spine flexion range of motion (ROM). OBJECTIVES: To determine Intra and Inter-rater reliability of mobile device goniometer in measuring lumbar flexion range of motion. METHOD: iPod mobile device with goniometer software was used. The part being measure i.e the back of the subject was suitably exposed. Subject was standing with feet shoulder width apart. Spinous process of second sacral vertebra S2 and T12 were located, these were used as the reference points and readings were taken. Three readings were taken for each: inter-rater reliability as well as the intra-rater reliability. Sufficient rest was given between each flexion movement. RESULTS: Intra-rater reliability using ICC was r = 0.920 and inter-rater r = 0.812 at CI 95%. Validity r = 0.95. CONCLUSION: Mobile device goniometer has high intra-rater reliability. The inter-rater reliability was moderate. This device can be used to assess range of motion of spine flexion, representing uni-planar movement.
引用
收藏
页码:161 / 166
页数:6
相关论文
共 50 条
  • [1] VALIDITY AND INTRA-RATER RELIABILITY OF LASER GONIOMETER VERSUS ELECTRO-GONIOMETER IN MEASURING SHOULDER RANGE OF MOTION
    Elgendy, Mohammed H.
    Abd El-khalek, Wael O. A.
    INTERNATIONAL JOURNAL OF PHYSIOTHERAPY, 2019, 6 (05) : 169 - 176
  • [2] Inter-rater and intra-rater reliability of Kinovea software for measurement of shoulder range of motion
    Reham M. Abd Elrahim
    Eman A. Embaby
    Mohamed F. Ali
    Ragia M. Kamel
    Bulletin of Faculty of Physical Therapy, 2016, 21 (2) : 80 - 87
  • [3] Intra-rater and Inter-rater Reliability of Mandibular Range of Motion Measures Considering a Neutral Craniocervical Position
    Beltran-Alacreu, Hector
    Lopez-de-Uralde-Villanueva, Ibai
    Paris-Alemany, Alba
    Angulo-Diaz-Parreno, Santiago
    La Touche, Roy
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2014, 26 (06) : 915 - 920
  • [4] Inter-rater and Intra-rater Reliability of a Mobile App Method to Measure Lumbar Lordosis
    Gnanasigamani, Jency Thangasheela
    Ramalingam, Vinodhkumar
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (03)
  • [5] Measuring Essay Assessment: Intra-rater and Inter-rater Reliability
    Kayapinar, Ulas
    EURASIAN JOURNAL OF EDUCATIONAL RESEARCH, 2014, (57): : 113 - 135
  • [6] Inter-rater, intra-rater and inter-instrument reliability of an electrogoniometer to measure wrist range of motion
    da Silva Camassuti, Patricia Aparecida
    Marcolino, Alexandre Marcio
    Tamanini, Guilherme
    Barbosa, Rafael Inacio
    Barbosa, Amanda Matias
    Registro Fonseca, Marisa de Cassia
    HAND THERAPY, 2015, 20 (01) : 3 - 10
  • [7] Inter and intra-rater reliability of the scoliometer
    Bonagamba, Guilherme H.
    Coelho, Daniel M.
    de Oliveira, Anamaria S.
    BRAZILIAN JOURNAL OF PHYSICAL THERAPY, 2010, 14 (05) : 432 - 437
  • [8] Inter-rater and intra-rater reliability of isotonic exercise monitoring device for measuring active knee extension
    Limsakul, Chonnanid
    Sengchuai, Kiattisak
    Duangsoithong, Rakkrit
    Jindapetch, Nattha
    Jaruenpunyasak, Jermphiphut
    PEERJ, 2023, 11
  • [9] Inter- and intra-rater reliability for measurement of range of motion in joints included in three hypermobility assessment methods
    Angela Schlager
    Kerstin Ahlqvist
    Eva Rasmussen-Barr
    Elisabeth Krefting Bjelland
    Ronnie Pingel
    Christina Olsson
    Lena Nilsson-Wikmar
    Per Kristiansson
    BMC Musculoskeletal Disorders, 19
  • [10] Measuring shoulder external and internal rotation strength and range of motion: comprehensive intra-rater and inter-rater reliability study of several testing protocols
    Cools, Ann M.
    De Wilde, Lieven
    Van Tongel, Alexander
    Ceyssens, Charlotte
    Ryckewaert, Robin
    Cambier, Dirk C.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2014, 23 (10) : 1454 - 1461