A general method for measurement of the time integral of variant magnetic field gradients: Application to 2D spiral imaging

被引:33
作者
Papadakis, NG [1 ]
Wilkinson, AA [1 ]
Carpenter, TA [1 ]
Hall, LD [1 ]
机构
[1] UNIV CAMBRIDGE,SCH CLIN MED,HERCHEL SMITH LAB MED CHEM,CAMBRIDGE CB2 2PZ,ENGLAND
关键词
magnetic resonance imaging; k-space trajectory; fast imaging; spiral scan;
D O I
10.1016/S0730-725X(97)00014-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A new method is proposed by which the time integral of time-varying magnetic fields in different voxels can be determined by MRI. A further processing step is employed which enables the integral of the magnetic field gradients experienced by groups of voxels to be deduced. Analysis of the theoretical background and complete simulations have been used to assess the limitations of the technique and the method is applied to the measurement of a 2D spiral k-space trajectory and also of its 1D components. These measured trajectories have been used to reconstruct images from experimental spiral-scan raw data of a phantom acquired using the 2D spiral k-space trajectory. Comparisons of the resulting images are made with the image reconstructed using the corresponding theoretical trajectory. The importance of the repeatability, reliability and accuracy of the technique is demonstrated. (C) 1997 Elsevier Science Inc.
引用
收藏
页码:567 / 578
页数:12
相关论文
共 21 条
  • [1] HIGH-SPEED SPIRAL-SCAN ECHO PLANAR NMR IMAGING .1.
    AHN, CB
    KIM, JH
    CHO, ZH
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1986, 5 (01) : 2 - 7
  • [2] Bracewell R., 1984, FOURIER TRANSFORM IT
  • [3] FLOW-VELOCITY IMAGING FROM LINEAR-REGRESSION OF PHASE IMAGES WITH TECHNIQUES FOR REDUCING EDDY-CURRENT EFFECTS
    CAPRIHAN, A
    ALTOBELLI, SA
    BENITEZREAD, E
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1990, 90 (01) : 71 - 89
  • [4] ULTRA-FAST IMAGING
    COHEN, MS
    WEISSKOFF, RM
    [J]. MAGNETIC RESONANCE IMAGING, 1991, 9 (01) : 1 - 37
  • [5] Design and evaluation of a transverse gradient set for magnetic resonance imaging of the human brain
    Fisher, BJ
    Dillon, N
    Wilkinson, AA
    Carpenter, TA
    Hall, LD
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 1996, 7 (05) : 838 - 843
  • [6] AN EFFICIENT, HIGHLY HOMOGENEOUS RADIOFREQUENCY COIL FOR WHOLE-BODY NMR IMAGING AT 1.5-T
    HAYES, CE
    EDELSTEIN, WA
    SCHENCK, JF
    MUELLER, OM
    EASH, M
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1985, 63 (03) : 622 - 628
  • [7] Inhomogeneity correction using an estimated linear field map
    Irarrazabal, P
    Meyer, CH
    Nishimura, DG
    Macovski, A
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (02) : 278 - 282
  • [8] TWISTING RADIAL LINES WITH APPLICATION TO ROBUST MAGNETIC-RESONANCE-IMAGING OF IRREGULAR FLOW
    JACKSON, JI
    NISHIMURA, DG
    MACOVSKI, A
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1992, 25 (01) : 128 - 139
  • [9] A SIMPLE GRAPHICAL REPRESENTATION OF FOURIER-BASED IMAGING METHODS
    LJUNGGREN, S
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1983, 54 (02) : 338 - 343
  • [10] MULTI-PLANAR IMAGE-FORMATION USING NMR SPIN ECHOES
    MANSFIELD, P
    [J]. JOURNAL OF PHYSICS C-SOLID STATE PHYSICS, 1977, 10 (03): : L55 - L58