Predictors of event-free survival after repeat intracoronary procedure for in-stent restenosis - Study with angiographic and intravascular ultrasound imaging

被引:14
|
作者
Schiele, F [1 ]
Meneveau, N [1 ]
Seronde, MF [1 ]
Deforet, MF [1 ]
Gupta, S [1 ]
Bassand, JP [1 ]
机构
[1] Hop Univ Jean Minjoz, Serv Cardiol, F-25030 Besancon, France
关键词
in-stent restenosis; intravascular ultrasound; angioplasty; rotational atherectomy;
D O I
10.1053/euhj.1999.1906
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Lumen enlargement during repeat percutaneous coronary intervention for in-stent restenosis has been shown to be the result of both stent over-expansion and decrease in neointimal tissue. How these two different mechanisms of action may influence outcome and target lesion revascularization after repeat intervention for in-stent restenosis is unclear. Methods Intravascular ultrasound guided repeat intervention for in-stent restenosis was carried out either with balloon angioplasty, or with a combination of rotational atherectomy plus balloon angioplasty. Clinical follow-up at I year, including death, myocardial infarction, or need for revascularization, was obtained. Results Seventy patients were included in this study; 40 were treated by balloon alone, and 30 by combination of rotational atherectomy plus balloon. Event-free survival probability tvas 76 +/- 5%. The mechanism of lumen enlargement, be it stent over-expansion or tissue removal, had no influence on long-term clinical evolution. The only independent predictor was the minimal lumen cross-sectional area at the end of the procedure, the larger the lumen cross-sectional area? the higher the event-free probability. The cut-off point of the lumen cross-sectional area was set at 4.7 mm(2) by discriminant analysis. Event-free survival was 69 +/- 15% in patients with <4.7 mm(2) lumen cross-sectional area and 91 +/- 8% in patients with >4.7 mm(2) lumen cross-sectional area (P=0.008). Conclusions This study showed that the only independent predictor of late clinical outcome after percutaneous re-intervention for in-stent restenosis was final lumen size, no matter which means were used to achieve it. (C) 2000 The European Society of Cardiology.
引用
收藏
页码:754 / 762
页数:9
相关论文
共 31 条
  • [1] Intravascular Ultrasound and Angiographic Predictors of In-Stent Restenosis of Chronic Total Occlusion Lesions
    Kang, Jeehoon
    Cho, Young-Seok
    Kim, Seong-Wook
    Park, Jin Joo
    Yoon, Yeonyee E.
    Oh, Il-Young
    Yoon, Chang-Hwan
    Suh, Jung-Won
    Youn, Tae-Jin
    Chae, In-Ho
    Choi, Dong-Ju
    PLOS ONE, 2015, 10 (10):
  • [2] Morphological effects on in-stent restenosis assessed by intravascular ultrasound imaging
    Yamaguchi, T
    Hamasaki, S
    Arima, S
    Biro, S
    Kihara, K
    Fukumoto, N
    Kamekou, M
    Nakano, F
    Yoshitama, T
    Kiyonaga, K
    Nakjima, H
    Nakao, S
    Tei, C
    JAPANESE HEART JOURNAL, 1999, 40 (02): : 109 - 118
  • [3] Soft plaque detected on intravascular ultrasound is the strongest predictor of in-stent restenosis: an intravascular ultrasound study
    Sahara, M
    Kirigaya, H
    Oikawa, Y
    Yajima, J
    Nagashima, K
    Hara, H
    Ogasawara, K
    Aizawa, T
    EUROPEAN HEART JOURNAL, 2004, 25 (22) : 2026 - 2033
  • [4] Mechanism of cutting balloon angioplasty for in-stent restenosis: An intravascular ultrasound study
    Montorsi, P
    Galli, S
    Fabbiocchi, F
    Loaldi, A
    Trabattoni, D
    Grancini, L
    Cozzi, S
    Ravagnani, P
    Parodi, O
    Bartorelli, AL
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2002, 56 (02) : 166 - 173
  • [5] Patterns and mechanisms of in-stent restenosis - A serial intravascular ultrasound study
    Hoffmann, R
    Mintz, GS
    Dussaillant, GR
    Popma, JJ
    Pichard, AD
    Satler, LF
    Kent, KM
    Griffin, J
    Leon, MB
    CIRCULATION, 1996, 94 (06) : 1247 - 1254
  • [6] Mechanisms of In-Stent Restenosis After Drug-Eluting Stent Implantation Intravascular Ultrasound Analysis
    Kang, Soo-Jin
    Mintz, Gary S.
    Park, Duk-Woo
    Lee, Seung-Whan
    Kim, Young-Hak
    Lee, Cheol Whan
    Han, Ki-Hoon
    Kim, Jae-Joong
    Park, Seong-Wook
    Park, Seung-Jung
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (01) : 9 - 14
  • [7] Intravascular Ultrasound-Derived Stent Dimensions as Predictors of Angiographic Restenosis Following Nitinol Stent Implantation in the Superficial Femoral Artery
    Miki, Kojiro
    Fujii, Kenichi
    Kawasaki, Daizo
    Shibuya, Masahiko
    Fukunaga, Masashi
    Imanaka, Takahiro
    Tamaru, Hiroto
    Sumiyoshi, Akinori
    Nishimura, Machiko
    Horimatsu, Tetsuo
    Saita, Ten
    Okada, Kozo
    Kimura, Takumi
    Honda, Yasuhiro
    Fitzgerald, Peter J.
    Masuyama, Tohru
    Ishihara, Masaharu
    JOURNAL OF ENDOVASCULAR THERAPY, 2016, 23 (03) : 424 - 432
  • [8] Nine-Month Angiographic and Intravascular Ultrasound Outcomes After Resolute Zotarolimus-Eluting Stent Implantation for the Treatment of In-Stent Restenosis
    Lee, Seung-Yul
    Kim, Byeong-Keuk
    Kim, Jung-Sun
    Hong, Myeong-Ki
    Cho, Deok-Kyu
    Yoon, Junghan
    Jeon, Dong Woon
    Lee, Nam-Ho
    Kwon, Hyuck Moon
    Jang, Yangsoo
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2013, 26 (06) : 543 - 549
  • [9] Duration of development of symptomatic in-stent restenosis correlates with the stent-to-vessel-diameter ratio:: an intravascular ultrasound study
    Schukro, Christoph
    Gruska, Michael
    Syeda, Bonni
    Winkler, Michael
    Poradek, Thomas
    Sipoetz, Hans
    Glogar, Dietmar
    Gaul, Georg
    CORONARY ARTERY DISEASE, 2007, 18 (07) : 507 - 512
  • [10] Association of Coronary Artery Severity and Late In-Stent Restenosis: An Angiographic Imaging Study
    Oguz, Mustafa
    Akbulut, Tayyar
    Saylik, Faysal
    Sipal, Abdulcabbar
    Erdal, Emrah
    ANGIOLOGY, 2024, 75 (02) : 122 - 130