Resonance frequency analysis for osseointegration in four surgical conditions of dental implants

被引:0
作者
Lin, SF [1 ]
Pan, LC [1 ]
Lee, SY [1 ]
Peng, LH [1 ]
Hsiao, TC [1 ]
机构
[1] Taipei Med Univ, Grad Inst Oral Rehab Sci, Taipei, Taiwan
来源
PROCEEDINGS OF THE 23RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: BUILDING NEW BRIDGES AT THE FRONTIERS OF ENGINEERING AND MEDICINE | 2001年 / 23卷
关键词
dental implant; osseointegration; resonance frequency; stability;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The establishment of osseointegration following dental implant placement is a major contributing factor to the clinical success and long-term function of implant-retained prosthesis. Radiographic examination and palpation have been two of the methods often used in clinical assessment for implant stability for years. However, theses radiographs are two-dimensional and difficult to standardize. The investigation was designed to study the use of resonance frequency analysis in search of the stability of the implant-tissue interface in vitro. Resonance frequency was measured when test implants were embedded in bakelites. The change in stiffness observed during bone healing was modeled by embedding implants in gypsum during setting period. Our results showed that there was an increase in resonance frequency related to stiffness increment during osseointegration.
引用
收藏
页码:2998 / 3001
页数:4
相关论文
共 13 条
[1]  
ADELL R, 1985, TISSUE INTEGRATED PR, P211
[2]   STATE-OF-THE-ART IN ORAL IMPLANTS [J].
ALBREKTSSON, T ;
SENNERBY, L .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1991, 18 (06) :474-481
[3]   Biomechanical study of screws in the lateral masses: Variables affecting pull-out resistance [J].
Heller, JG ;
Estes, BT ;
Zaouali, M ;
Diop, A .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1996, 78A (09) :1315-1321
[4]   THE EXCESSIVE LOSS OF BRANEMARK FIXTURES IN TYPE-IV BONE - A 5-YEAR ANALYSIS [J].
JAFFIN, RA ;
BERMAN, CL .
JOURNAL OF PERIODONTOLOGY, 1991, 62 (01) :2-4
[5]  
Johansson C, 1987, Int J Oral Maxillofac Implants, V2, P69
[6]   DYNAMIC MODEL OF A HEALING FRACTURED LONG BONE [J].
LEWIS, JL .
JOURNAL OF BIOMECHANICS, 1975, 8 (01) :17-25
[7]   THE RELATION BETWEEN RESONANT FREQUENCIES AND TORSIONAL STIFFNESS OF LONG BONES INVITRO - VALIDATION OF A SIMPLE BEAM MODEL [J].
LOWET, G ;
VANAUDEKERCKE, R ;
VANDERPERRE, G ;
GEUSENS, P ;
DEQUEKER, J ;
LAMMENS, J .
JOURNAL OF BIOMECHANICS, 1993, 26 (06) :689-696
[8]   The application of resonance frequency measurements to study the stability of titanium implants during healing in the rabbit tibia [J].
Meredith, N ;
Shagaldi, F ;
Alleyne, D ;
Sennerby, L ;
Cawley, P .
CLINICAL ORAL IMPLANTS RESEARCH, 1997, 8 (03) :234-243
[9]  
Meredith N, 1994, J DENT RES, V73, P793
[10]  
OLIVE J, 1990, International Journal of Oral and Maxillofacial Implants, V5, P390