Computed Tomography-Based Tumor Volume in Non-Hodgkin Lymphoma: Clinical Correlation and Comparison With Magnetic Resonance Imaging

被引:3
作者
Rossi, Maija [1 ]
Pertovaara, Hannu [2 ]
Dastidar, Prasun [1 ,4 ]
Jarvenpaa, Ritva [1 ]
Luukkaala, Tiina [3 ,5 ]
Rautakunnas, Sylvia [1 ,4 ]
Heinonen, Tomi [6 ]
Eskola, Hannu [1 ,6 ]
Soimakallio, Seppo [1 ,4 ]
Kellokumpu-Lehtinen, Pirkko-Liisa [2 ,4 ]
机构
[1] Tampere Univ Hosp, Dept Diagnost Radiol, Reg Med Imaging Ctr, Tampere 33521, Finland
[2] Tampere Univ Hosp, Dept Oncol, Tampere 33521, Finland
[3] Pirkanmaa Univ Hosp Dist, Ctr Sci, Tampere, Finland
[4] Pirkanmaa Univ Hosp Dist, Tampere Med Sch, Tampere, Finland
[5] Univ Tampere, Tampere Sch Publ Hlth, FIN-33101 Tampere, Finland
[6] Tampere Univ Technol, Dept Biomed Engn, FIN-33101 Tampere, Finland
关键词
computed tomography; non-Hodgkin lymphoma; response monitoring; volumetric analysis; LARGE-CELL LYMPHOMA; POSITRON-EMISSION-TOMOGRAPHY; THERAPEUTIC RESPONSE; SOLID TUMORS; CT; SEGMENTATION; CRITERIA; DISEASE; VARIABILITY; LESIONS;
D O I
10.1097/RCT.0b013e3181885971
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To evaluate the prognostic significance of tumor volume in computed tomographic (CT) images of non-Hodgkin lymphoma patients. To compare CT volumes with those measured by magnetic resonance imaging (MRI). Methods: Twenty-five patients with B cell-type non-Hodgkin lymphoma (16 men, 9 women, age range, 48-77 years) were imaged with CT at 5 time points. The volumes and volume reductions were associated with clinical characteristics and treatment outcome. The CT-derived tumor volumes were correlated with MRI volumes derived earlier for the same patients. Results: Good agreement was found between 1-dimensional (1D), 2D, and 3D analyses. The CT-derived median turner volumes were 306 cm 3, 174 cm(3), 75 cm(3), 28 cm(3), and 15 cm(3) at the 5 time points. These volumes were found to associate, for example, with mortality and tumor malignancy. The CT-based tumor volumes showed good correlation with MRI. Conclusions: Tumor volume quantification is a powerful tool that associates with clinical characteristics and treatment outcome.
引用
收藏
页码:641 / 649
页数:9
相关论文
共 42 条
  • [1] Battmann A, 2001, STRAHLENTHER ONKOL, V177, P132, DOI 10.1007/PL00002393
  • [2] CARBONE PP, 1971, CANCER RES, V31, P1860
  • [3] Liver volumetry plug and play: Do it yourself with ImageJ
    Dello, Simon A. W. G.
    van Dam, Ronald M.
    Slangen, Jules J. G.
    de Poll, Marcel C. G. van
    Bemelmans, Marc H. A.
    Greve, Jan Willem W. M.
    Beets-Tan, Regina G. H.
    Wigmore, Stephen J.
    Dejong, Cornelis H. C.
    [J]. WORLD JOURNAL OF SURGERY, 2007, 31 (11) : 2215 - 2221
  • [4] Pulmonary nodules: Interscan variability of semiautomated volume measurements with multisection CT-influence of inspiration level, nodule size, and segmentation performance
    Gietema, Hester A.
    Schaefer-Prokop, Cornelia M.
    Mali, Willem P. T. M.
    Groenewegen, Gerard
    Prokop, Mathias
    [J]. RADIOLOGY, 2007, 245 (03) : 888 - 894
  • [5] Image-aided estimate of tumor burden in Hodgkin's disease:: Evidence of its primary prognostic importance
    Gobbi, PG
    Ghirardelli, ML
    Solcia, M
    Di Giulio, G
    Merli, F
    Tavecchia, L
    Bertè, R
    Davini, O
    Levis, A
    Broglia, C
    Maffè, GC
    Ilariucci, F
    Dore, R
    Ascari, E
    [J]. JOURNAL OF CLINICAL ONCOLOGY, 2001, 19 (05) : 1388 - 1394
  • [6] Texture analysis on MRI images of non-Hodgkin lymphoma
    Harrison, L.
    Dastidar, P.
    Eskola, H.
    Jarvenpaa, R.
    Pertovaara, H.
    Luukkaalarg, T.
    Kellokumpu-Lehtinen, P-L.
    Soimakallio, S.
    [J]. COMPUTERS IN BIOLOGY AND MEDICINE, 2008, 38 (04) : 519 - 524
  • [7] Hauth EAM, 2007, RADIOLOGE, V47, P628, DOI 10.1007/s00117-005-1329-4
  • [8] Applicability of semi-automatic segmentation for volumetric analysis of brain lesions
    Heinonen, T
    Dastidar, P
    Eskola, H
    Frey, H
    Ryymin, P
    Laasonen, E
    [J]. JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 1998, 22 (04) : 173 - 178
  • [9] Semi-automatic tool for segmentation and volumetric analysis of medical images
    Heinonen, T
    Dastidar, P
    Kauppinen, P
    Malmivuo, J
    Eskola, H
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1998, 36 (03) : 291 - 296
  • [10] Liver segmentation in living liver transplant donors: Comparison of semiautomatic and manual methods
    Hermoye, L
    Laamari-Azjal, I
    Cao, ZJ
    Annet, L
    Lerut, J
    Dawant, BM
    Van Beers, BE
    [J]. RADIOLOGY, 2005, 234 (01) : 171 - 178