Modeling evaluation of a direct-expansion solar-assisted heat pump water heater using R410A

被引:73
作者
Kong, X. Q. [1 ]
Li, Y. [1 ]
Lin, L. [1 ]
Yang, Y. G. [1 ]
机构
[1] Shandong Univ Sci & Technol, Sch Mech & Elect Engn, Qingdao 266590, Peoples R China
来源
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | 2017年 / 76卷
关键词
Solar-assisted heat pump; Direct-expansion; R410A; Performance; Modeling; EXERGY ANALYSIS; PERFORMANCE; SYSTEM; OPTIMIZATION; REFRIGERANT; COMPRESSOR; VALIDATION; R22;
D O I
10.1016/j.ijrefrig.2017.01.020
中图分类号
O414.1 [热力学];
学科分类号
摘要
A direct-expansion solar-assisted heat pump (DX-SAHP) system by using R410A as refrigerant is described, which can supply domestic hot water during the whole year. Based on the distributed parameter and homogeneous flow models of collector/evaporator and condenser, the lumped parameter models of compressor and electronic expansion valve, and the refrigerant charge model, a numerical model is developed to estimate the thermal performance of the system. Given the structure parameters, meteorological parameters, initial and final water temperatures, for a fixed superheat degree, the effects of the refrigerant charge quantity on the performance parameters of the system are analyzed, such as compressor power, heat gain of collector, heating time, collector efficiency and system COP. Furthermore, for a fixed refrigerant charge quantity, the effects of various parameters, including solar radiation, ambient temperature, compressor speed and initial water temperature, have been simulated and analyzed on the thermal performance of the system. (C) 2017 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:136 / 146
页数:11
相关论文
共 39 条
[1]   Exergy analysis and operational efficiency of a horizontal ground-source heat pump system operated in low-energy test house under simulated occupancy conditions [J].
Ally, Moonis R. ;
Munk, Jeffrey D. ;
Baxter, Van D. ;
Gehl, Anthony C. .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2012, 35 (04) :1092-1103
[2]  
Calm J.M., 2001, ENG SYSTEMS, V18, P74
[3]  
Cao Xiao-lin, 2010, Journal of Central South University (Science and Technology), V41, P759
[4]   Two-stage direct expansion solar-assisted heat pump for high temperature applications [J].
Chaturvedi, S. K. ;
Abdel-Salam, T. M. ;
Sreedharan, S. S. ;
Gorozabel, F. B. .
APPLIED THERMAL ENGINEERING, 2009, 29 (10) :2093-2099
[5]  
[陈九法 Chen Juifa], 2005, [流体机械, Fluid Machinery], V33, P78
[6]   A comparative study on the performance and environmental characteristics of R410A and R22 residential air conditioners [J].
Chen, W. .
APPLIED THERMAL ENGINEERING, 2008, 28 (01) :1-7
[7]   Modeling and application of direct-expansion solar-assisted heat pump for water heating in subtropical Hong Kong [J].
Chow, T. T. ;
Pei, G. ;
Fong, K. F. ;
Lin, Z. ;
Chan, A. L. S. ;
He, M. .
APPLIED ENERGY, 2010, 87 (02) :643-649
[8]  
Ding G. L., 2003, NEW REFRIGERANT AIR, P28
[9]  
Duffie J.A., 1991, SOLAR ENG THERMAL PR, P250
[10]   Modelling and validation of a gas engine heat pump working with R410A for cooling applications [J].
Elgendy, E. ;
Schmidt, J. ;
Khalil, A. ;
Fatouh, M. .
APPLIED ENERGY, 2011, 88 (12) :4980-4988