Correcting the inherent distortion in luminescence images of silicon solar cells

被引:0
作者
Teal, Anthony [1 ]
Juhl, Mattias [1 ]
机构
[1] Univ New S Wales, ANZAC Pde, Sydney, NSW 2052, Australia
来源
2015 IEEE 42ND PHOTOVOLTAIC SPECIALIST CONFERENCE (PVSC) | 2015年
关键词
electroluminescence imaging; photoluminescence imaging; photovoltaics; point spread function; PSF; silicon solar cell; POINT-SPREAD FUNCTION;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Luminescence imaging of Silicon solar cells is typically performed with a silicon CCD, which is a poor absorber of silicon luminescence (900-1300 nm). This leads to a phenomenon referred to as photon smearing in the CCD, where a photon incident on one pixel may be absorbed in another. This makes the image blurry and quantitative analysis of this data inaccurate. Also resolution, contrast, and sharpness of the image are reduced at features such as grain boundaries, and sample edges. An already established method of recovering the original luminescence signal incident on the CCD is to deconvolve a Point Spread Function (PSF) with the resultant image. This paper focuses on a novel method for determining the PSF from a measurement of the Edge Spread Function, which greatly increases the Signal to Noise ratio over methods where the PSF is measured directly. The determined PSF and its application to luminescence images, is compared and contrasted with previously published PSF determination methods.
引用
收藏
页数:5
相关论文
共 13 条
[1]   Toward high-precision astrometry with WFPC2. I. Deriving an accurate point-spread function [J].
Anderson, J ;
King, IR .
PUBLICATIONS OF THE ASTRONOMICAL SOCIETY OF THE PACIFIC, 2000, 112 (776) :1360-1382
[2]  
Boreman G.D., 2001, MODULATION TRANSFER, V4
[3]   Effects of point-spread function on calibration and radiometric accuracy of CCD camera [J].
Du, H ;
Voss, KJ .
APPLIED OPTICS, 2004, 43 (03) :665-670
[4]   Advanced luminescence based effective series resistance imaging of silicon solar cells [J].
Kampwerth, H. ;
Trupke, T. ;
Weber, J. W. ;
Augarten, Y. .
APPLIED PHYSICS LETTERS, 2008, 93 (20)
[5]  
Kyprianou I. S., 2007, METHOD ESTIMATE POIN
[6]   Imaging interstitial iron concentrations in boron-doped crystalline silicon using photoluminescence [J].
Macdonald, D. ;
Tan, J. ;
Trupke, T. .
JOURNAL OF APPLIED PHYSICS, 2008, 103 (07)
[7]   On the method of photoluminescence spectral intensity ratio imaging of silicon bricks: Advances and limitations [J].
Mitchell, Bernhard ;
Weber, Juergen W. ;
Walter, Daniel ;
Macdonald, Daniel ;
Trupke, Thorsten .
JOURNAL OF APPLIED PHYSICS, 2012, 112 (06)
[8]   Measuring the PSF from aperture images of arbitrary shape - an algorithm [J].
Nakashima, PNH ;
Johnson, AWS .
ULTRAMICROSCOPY, 2003, 94 (02) :135-148
[9]   A method for measuring the presampled MTF of digital radiographic systems using an edge test device [J].
Samei, E ;
Flynn, MJ ;
Reimann, DA .
MEDICAL PHYSICS, 1998, 25 (01) :102-113
[10]  
Teal A, 2014, SOL ENERG MAT SOL C, V130, P1, DOI 10.1016/j.solmat.2014.06.024