A Simple Self-Tuning Resonant Control Approach for Power Converters Connected to Micro-Grids With Distorted Voltage Conditions

被引:17
作者
Rohten, Jaime Addin [1 ]
Silva, Jose Javier [2 ]
Munoz, Javier A. [3 ]
Villarroel, Felipe A. [2 ]
Dewar, David N. [4 ]
Rivera, Marco E. [3 ]
Espinoza, Jose R. [2 ]
机构
[1] Univ Bio Bio, Dept Elect & Elect Engn, Concepcion 4051381, Chile
[2] Univ Concepcion, Dept Elect Engn, Concepcion 4070386, Chile
[3] Univ Talca, Dept Elect Engn, Curico 3340000, Chile
[4] Univ Nottingham, Dept Elect & Elect Engn, Nottingham NG7 2RD, England
关键词
Frequency control; Resonant frequency; Power harmonic filters; Frequency conversion; Harmonic analysis; Voltage control; Time-frequency analysis; Resonant control; variable frequency environment; micro-grids; SAMPLING FREQUENCY; GENERATION;
D O I
10.1109/ACCESS.2020.3041528
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Over the last few decades, the consolidated goal of reducing greenhouse gasses has increased the relevance of renewable energy research, electromobility, energy storage, and distributed generation, micro-grids, among others. Micro-grids, systems working in islanding mode, are particular cases where some disadvantages are present due to the wide variations which may appear across their electrical quantities. Variations on the voltage amplitude and the frequency are intrinsic in the operation of weak grids, because they have low inertia and therefore the load must be able to cope with these variations, otherwise loads may trip electrical system protection. Particularly, on power electronic drives, these frequency deviations will lead to increased system nonlinearities, entailing a more critical controller design. To overcome these issues, this paper presents an implementation of a resonant controller with self-tuned gains. The strategy imposes a constant sampling time which allows these controllers to be used in variable frequency environments. In addition, the computational capacity required for the digital board is also considered. The simulated and experimental results provided demonstrate the good performance of this proposal.
引用
收藏
页码:216018 / 216028
页数:11
相关论文
共 27 条
[1]  
[Anonymous], 2007, DIGITAL SIGNAL PROCE
[2]   A New Single-Phase AC Voltage Converter With Voltage Buck Characteristics for Grid Voltage Compensation [J].
Ashraf, Naveed ;
Izhar, Tahir ;
Abbas, Ghulam ;
Awan, Ahmed Bilal ;
Farooq, Umar ;
Balas, Valentina E. .
IEEE ACCESS, 2020, 8 :48886-48903
[3]  
Bouzid AM, 2014, PROC IEEE INT SYMP, P2371, DOI 10.1109/ISIE.2014.6864990
[4]  
Bouzid A.M., 2015, EC VEH REN EN EVER 2, P1, DOI [10.1109/CEIT.2015.7233086, DOI 10.1109/CEIT.2015.7233086]
[5]   Robust three degrees of freedom based on H∞ controller of voltage/current loops for DG unit in micro grids [J].
Bouzid, Allal El Moubarek ;
Sicard, Pierre ;
Chaoui, Hicham ;
Cheriti, Ahmed .
IET POWER ELECTRONICS, 2019, 12 (06) :1413-1424
[6]   Variable, fixed, and hybrid sampling period approach for grid synchronization [J].
Carugati, Ignacio ;
Orallo, Carlos M. ;
Maestri, Sebastian ;
Donato, Patricio G. ;
Carrica, Daniel .
ELECTRIC POWER SYSTEMS RESEARCH, 2017, 144 :23-31
[7]   Variable Sampling Period Filter PLL for Distorted Three-Phase Systems [J].
Carugati, Ignacio ;
Maestri, Sebastian ;
Donato, Patricio G. ;
Carrica, Daniel ;
Benedetti, Mario .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2012, 27 (01) :321-330
[8]   Robust Normalized Mixed-Norm Adaptive Control Scheme for PQ Improvement at PCC of a Remotely Located Wind-Solar PV-BES Microgrid [J].
Chishti, Farheen ;
Murshid, Shadab ;
Singh, Bhim .
IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2020, 16 (03) :1708-1721
[9]  
Devi N, 2020, INT J PROGRESSIVE RE, V1, P217
[10]   A Discrete-Time Frequency-Locked Loop for Single-Phase Grid Synchronization Under Harmonic Distortion [J].
Escobar, Gerardo ;
del Puerto-Flores, Dunstano ;
Mayo-Maldonado, Jonathan C. ;
Valdez-Resendiz, Jesus E. ;
Miguel Micheloud-Vernackt, Osvaldo .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2020, 35 (05) :4647-4657