Microchip capillary electrophoresis with amperometric detection for several carbohydrates

被引:35
|
作者
Lee, HL [1 ]
Chen, SC [1 ]
机构
[1] Fu Jen Catholic Univ, Dept Chem, Taipei 242, Taiwan
关键词
carbohydrates; microchip; capillary electrophoresis; amperometric detection; copper electrode;
D O I
10.1016/j.talanta.2004.02.013
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Microchip capillary electrophoresis (muCE) with amperometric detection at Cu electrode benefited fast separation and direct detection of carbohydrates. The working electrode of 50-mum Cu wire attached nearly against the channel outlet-4 mum, where it benefited collecting detection current and suppressing overwhelming noise. The use of alkaline medium was essential to separating and detecting carbohydrates, which dissociated into the sensitive alcolate anions. The 10-cm serpentine chip, though lengthening the migration time, it provided better efficiency. Sucrose, cellobiose, glucose, and fructose migrated from the outlet in 400 s +2000 V. The linear calibration plots ranging from 10 to 1000 muM with regression coefficients better than 0.996 were obtained. The injection-to-injection reproducibility of 1.24% (n = 7) for glucose in peak current and 0.6% for migration times were excellent. The detection limit was low, down to 2.3 muM for glucose (SIN = 3) or 27.6 attomole in mass detection. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:210 / 216
页数:7
相关论文
共 50 条
  • [21] Capillary electrophoresis and microchip capillary electrophoresis with electrochemical and electrochemiluminescence detection
    Du, Yan
    Wang, Erkang
    JOURNAL OF SEPARATION SCIENCE, 2007, 30 (06) : 875 - 890
  • [22] Capillary electrophoresis on microchip
    Dolník, V
    Liu, SR
    Jovanovich, S
    ELECTROPHORESIS, 2000, 21 (01) : 41 - 54
  • [23] A disposable capillary electrophoresis microchip with an indium tin oxide decoupler/amperometric detector
    Kim, JH
    Kang, CJ
    Jeon, D
    Kim, YS
    MICROELECTRONIC ENGINEERING, 2005, 78-79 : 563 - 570
  • [24] Electrochemical determination of carbohydrates: Enzyme electrodes and amperometric detection in liquid chromatography and capillary electrophoresis
    Baldwin, RP
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 19 (1-2) : 69 - 81
  • [25] Dual Detection Methods for Microchip and Conventional Capillary Electrophoresis
    Li Xiang
    Tong Yan-Li
    Liu Cui
    Li Ou-Lian
    Yang Xiu-Juan
    Chen Zuan-Guang
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2009, 37 (10) : 1547 - 1554
  • [26] Detection of homocysteine by conventional and microchip capillary electrophoresis/electrochemistry
    Pasas, SA
    Lacher, NA
    Davies, MI
    Lunte, SM
    ELECTROPHORESIS, 2002, 23 (05) : 759 - 766
  • [27] Amperometric PDMS/glass capillary electrophoresis-based biosensor microchip for catechol and dopamine detection
    Schöning, MJ
    Jacobs, M
    Muck, A
    Knobbe, DT
    Wang, J
    Chatrathi, M
    Spillmann, S
    SENSORS AND ACTUATORS B-CHEMICAL, 2005, 108 (1-2): : 688 - 694
  • [28] Use of micromolded carbon dual electrodes with a palladium decoupler for amperometric detection in microchip electrophoresis
    Mecker, Laura C.
    Martin, R. Scott
    ELECTROPHORESIS, 2006, 27 (24) : 5032 - 5042
  • [29] Separation and determination of cyclodextrins by capillary electrophoresis with amperometric detection
    Fang, YZ
    Gong, FY
    Fang, XM
    Fu, CG
    ANALYTICA CHIMICA ACTA, 1998, 369 (1-2) : 39 - 45
  • [30] Simultaneous determination of carbohydrates and amino acids by capillary zone electrophoresis with constant potential amperometric detection at a copper electrode
    Hsi, TS
    Lin, JN
    Kuo, KY
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 1997, 44 (02) : 101 - 106