Nonlinear model predictive control of glucose concentration in subjects with type 1 diabetes

被引:770
作者
Hovorka, R
Canonico, V
Chassin, LJ
Haueter, U
Massi-Benedetti, M
Federici, MO
Pieber, TR
Schaller, HC
Schaupp, L
Vering, T
Wilinska, ME
机构
[1] Univ Cambridge, Addenbrookes Hosp, Diabet Modelling Grp, Dept Paediat, Cambridge CB2 2QQ, England
[2] Disetron Med Syst AG, Burgdorf, Switzerland
[3] Univ Perugia, I-06100 Perugia, Italy
[4] Graz Univ, Graz, Austria
关键词
nonlinear control; compartment modeling; Bayesian estimation;
D O I
10.1088/0967-3334/25/4/010
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A nonlinear model predictive controller has been developed to maintain normoglycemia in subjects with type 1 diabetes during fasting conditions such as during overnight fast. The controller employs a compartment model, which represents the glucoregulatory system and includes submodels representing absorption of subcutaneously administered short-acting insulin Lispro and gut absorption. The controller uses Bayesian parameter estimation to determine time-varying model parameters. Moving target trajectory facilitates slow, controlled normalization of elevated glucose levels and faster normalization of low glucose values. The predictive capabilities of the model have been evaluated using data from 15 clinical experiments in subjects with type 1 diabetes. The experiments employed intravenous glucose sampling (every 15 min) and subcutaneous infusion of insulin Lispro by insulin pump (modified also every 15 min). The model gave glucose predictions with a mean square error proportionally related to the prediction horizon with the value of 0.2 mmol L-1 per 15 min. The assessment of clinical utility of model-based glucose predictions using Clarke error grid analysis gave 95% of values in zone A and the remaining 5% of values in zone B for glucose predictions up to 60 min (n = 1674). In conclusion, adaptive nonlinear model predictive control is promising for the control of glucose concentration during fasting conditions in subjects with type 1 diabetes.
引用
收藏
页码:905 / 920
页数:16
相关论文
共 41 条
  • [1] ARTIFICIAL ENDOCRINE PANCREAS
    ALBISSER, AM
    LEIBEL, BS
    EWART, TG
    DAVIDOVAC, Z
    BOTZ, CK
    ZINGG, W
    [J]. DIABETES, 1974, 23 (05) : 389 - 396
  • [2] [Anonymous], 2003, Model Predictive Control
  • [3] Nonlinear model-based control of a batch reactive distillation column
    Balasubramhanya, LS
    Doyle, FJ
    [J]. JOURNAL OF PROCESS CONTROL, 2000, 10 (2-3) : 209 - 218
  • [4] ASSESSMENT OF INSULIN SENSITIVITY INVIVO - A CRITICAL-REVIEW
    BERGMAN, RN
    HOPE, ID
    YANG, YJ
    WATANABE, RM
    MEADOR, MA
    YOUN, JH
    ADER, M
    [J]. DIABETES-METABOLISM REVIEWS, 1989, 5 (05): : 411 - 429
  • [5] GLUCOSE DISPOSAL IS NOT PROPORTIONAL TO PLASMA-GLUCOSE LEVEL IN MAN
    BEST, JD
    TABORSKY, GJ
    HALTER, JB
    PORTE, D
    [J]. DIABETES, 1981, 30 (10) : 847 - 850
  • [6] A SIMULATION STUDY ON A SELF-TUNING PORTABLE CONTROLLER OF BLOOD-GLUCOSE
    BRUNETTI, P
    COBELLI, C
    CRUCIANI, P
    FABIETTI, PG
    FILIPPUCCI, F
    SANTEUSANIO, F
    SARTI, E
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1993, 16 (01) : 51 - 57
  • [7] AN ADAPTIVE PLASMA-GLUCOSE CONTROLLER BASED ON A NONLINEAR INSULIN/GLUCOSE MODEL
    CANDAS, B
    RADZIUK, J
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1994, 41 (02) : 116 - 124
  • [8] Chassin LJ, 2001, DIABETOLOGIA, V44, pA58
  • [9] CHASSIN LJ, 2004, IN PRESS ARTIF INTEL
  • [10] EVALUATING CLINICAL ACCURACY OF SYSTEMS FOR SELF-MONITORING OF BLOOD-GLUCOSE
    CLARKE, WL
    COX, D
    GONDERFREDERICK, LA
    CARTER, W
    POHL, SL
    [J]. DIABETES CARE, 1987, 10 (05) : 622 - 628