Speedup computation of HD-sEMG signals using a motor unit-specific electrical source model

被引:8
作者
Carriou, Vincent [1 ]
Boudaoud, Sofiane [1 ]
Laforet, Jeremy [1 ]
机构
[1] Univ Technol Compiegne, Sorbonne Univ, Ctr Rech Royallieu, CNRS,Biomech & Bioengn,UMR 7338, CS 60203, Compiegne, France
关键词
Motor unit electrical source; HD-sEMG model; Optimization; Computation time; Upscaling; SURFACE EMG; VOLUME CONDUCTOR; ACTION-POTENTIALS; GENERATION MODEL; MUSCLE; ELECTROMYOGRAPHY; ELECTRODES; SIMULATION; SYSTEM; FIBER;
D O I
10.1007/s11517-018-1784-5
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Nowadays, bio-reliable modeling of muscle contraction is becoming more accurate and complex. This increasing complexity induces a significant increase in computation time which prevents the possibility of using this model in certain applications and studies. Accordingly, the aim of this work is to significantly reduce the computation time of high-density surface electromyogram (HD-sEMG) generation. This will be done through a new model of motor unit (MU)-specific electrical source based on the fibers composing the MU. In order to assess the efficiency of this approach, we computed the normalized root mean square error (NRMSE) between several simulations on single generated MU action potential (MUAP) using the usual fiber electrical sources and the MU-specific electrical source. This NRMSE was computed for five different simulation sets wherein hundreds of MUAPs are generated and summed into HD-sEMG signals. The obtained results display less than 2% error on the generated signals compared to the same signals generated with fiber electrical sources. Moreover, the computation time of the HD-sEMG signal generation model is reduced to about 90% compared to the fiber electrical source model. Using this model with MU electrical sources, we can simulate HD-sEMG signals of a physiological muscle (hundreds of MU) in less than an hour on a classical workstation.
引用
收藏
页码:1459 / 1473
页数:15
相关论文
共 26 条
  • [1] Influence of motor unit synchronization on amplitude characteristics of surface and intramuscularly recorded EMG signals
    Arabadzhiev, Todor I.
    Dimitrov, Vladimir G.
    Dimitrova, Nonna A.
    Dimitrov, George V.
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2010, 108 (02) : 227 - 237
  • [2] Evaluation of muscle force classification using shape analysis of the sEMG probability density function: a simulation study
    Ayachi, F. S.
    Boudaoud, S.
    Marque, C.
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2014, 52 (08) : 673 - 684
  • [3] Three-layer volume conductor model and software package for applications in surface electromyography
    Blok, JH
    Stegeman, DF
    van Oosterom, A
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 2002, 30 (04) : 566 - 577
  • [4] Brown MB, 1960, J AM STAT ASSOC, V69, P364
  • [5] Sensitivity analysis of HD-sEMG amplitude descriptors relative to grid parameter variations of a cylindrical multilayered muscle model`
    Carriou, Vincent
    Laforet, Jeremy
    Boudaoud, Sofiane
    Al Harrach, Mariam
    [J]. BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2016, 2 (06):
  • [6] Carriou V, 2016, IEEE ENG MED BIO, P1704, DOI 10.1109/EMBC.2016.7591044
  • [7] Fast generation model of high density surface EMG signals in a cylindrical conductor volume
    Carriou, Vincent
    Boudaoud, Sofiane
    Laforet, Jeremy
    Ayachi, Fouaz Sofiane
    [J]. COMPUTERS IN BIOLOGY AND MEDICINE, 2016, 74 : 54 - 68
  • [8] EXTRACELLULAR POTENTIAL FIELD OF SINGLE ACTIVE NERVE FIBER IN A VOLUME CONDUCTOR
    CLARK, J
    PLONSEY, R
    [J]. BIOPHYSICAL JOURNAL, 1968, 8 (07) : 842 - &
  • [9] Precise and fast calculation of the motor unit potentials detected by a point and rectangular plate electrode
    Dimitrov, GV
    Dimitrova, NA
    [J]. MEDICAL ENGINEERING & PHYSICS, 1998, 20 (05) : 374 - 381
  • [10] A surface EMG generation model with multilayer cylindrical description of the volume conductor
    Farina, D
    Mesin, L
    Martina, S
    Merletti, R
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2004, 51 (03) : 415 - 426