Characterization of nitrogen-containing compounds in petroleum fractions by online reversed-phase liquid chromatography-electrospray ionization Orbitrap mass spectrometry

被引:24
|
作者
Xia, Yueyi [1 ,4 ]
Ma, Chenfei [2 ]
Ju, Ran [3 ]
Zhao, Chunxia [1 ]
Zheng, Fujian [1 ,4 ]
Sun, Xiaoshan [1 ,4 ]
Li, Zaifang [1 ,4 ]
Wang, Chunyan [2 ]
Shi, Dejun [2 ]
Lin, Xiaohui [3 ]
Lu, Xin [1 ]
Xu, Guowang [1 ]
机构
[1] Chinese Acad Sci, Dalian Inst Chem Phys, CAS Key Lab Separat Sci Analyt Chem, Dalian 116023, Peoples R China
[2] CNPC, PetroChina Petrochem Res Inst, Beijing 102206, Peoples R China
[3] Dalian Univ Technol, Sch Comp Sci & Technol, Dalian 116023, Peoples R China
[4] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
基金
中国国家自然科学基金;
关键词
Nitrogen-containing compounds; Petroleum fraction; Online Reverse phase liquid chromatography; High-resolution mass spectrometry; CRUDE-OIL; AROMATIC-COMPOUNDS; HEAVY PETROLEUM; RESOLUTION; HYDROCARBONS; ASPHALTENES; COMPONENTS;
D O I
10.1016/j.fuel.2020.119035
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Characterization of heteroatom compounds in crude oils is very important in petroleum production and processing. The ultrahigh-resolution Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) is a powerful MS technique for it but with expensive costs. It is necessary to develop a generally accepted alternative analytical approach to replace FT-ICR MS. In this study, a reversed-phase liquid chromatography (RPLC)-high-resolution (HR) MS method was proposed on an Orbitrap MS with electrospray ionization (ESI). The optimal chromatographic and MS parameters and internal mass calibration method were suggested. The sample complexity was greatly reduced by RPLC separation. Mass resolution (240 K at m/z 200) of Orbitrap MS was enough to obtain an accurate elemental assignment in complex petroleum fractions. False-positive element composition assignment could be easily excluded by the RPLC retention behavior of isomers. The performance of RPLC-Orbitrap MS was evaluated in comparison with direct injection (DI)-FT-ICR MS and DI-Orbitrap MS in positive ion mode for heavy oil analysis. The results showed that heteroatom class species, DBE vs carbon number distributions were very similar between RPLC-Orbitrap MS and DI-FT-ICR MS. The developed methods were further used to analyze petroleum oil fractions with boiling ranges at 180-350 degrees C, 350-530 degrees C and> 530 degrees C. Detailed heteroatom class species and corresponding DBE vs carbon number distributions were obtained. This study demonstrated that the RPLC-Orbitrap MS technique could successfully be applied for heteroatom compound characterization in petroleum fractions.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Retention behavior of lipids in reversed-phase ultrahigh-performance liquid chromatography-electrospray ionization mass spectrometry
    Ovcacikova, Magdalena
    Lisa, Miroslav
    Cifkova, Eva
    Holcapek, Michal
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1450 : 76 - 85
  • [2] Analysis of basic compounds by reversed-phase liquid chromatography-electrospray mass spectrometry in high-pH mobile phases
    Peng, Liming
    Farkas, Tivadar
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1179 (02) : 131 - 144
  • [3] Reversed-phase peptide mapping of glycoproteins using liquid chromatography electrospray ionization mass spectrometry
    Hancock, WS
    Apffel, A
    Chakel, J
    Souders, C
    MTimkulu, T
    Pungor, E
    Guzzetta, AW
    HIGH RESOLUTION SEPARATION AND ANALYSIS OF BIOLOGICAL MACROMOLECULES, PT B: APPLICATIONS, 1996, 271 : 403 - 427
  • [4] Extraction and Identification of Black Rice Polyphenolic Compounds by Reversed Phase High Performance Liquid Chromatography-Electrospray Ionization Mass Spectrometry
    Xie, Feng Ying
    Bi, Wei Wei
    Wang, Xiao Jun
    Zhang, Xiu Ling
    Zhang, Xiao Nan
    Zhao, Gui Xing
    Liu, Qian Qian
    JOURNAL OF FOOD PROCESSING AND PRESERVATION, 2017, 41 (05)
  • [5] Determination of distearyl dimethyl ammonium chloride in textiles by reversed-phase and normal-phase liquid chromatography-electrospray ionization tandem mass spectrometry
    Ding Youchao
    Shen Xiaoping
    Wu Xiaoqiong
    Wu Lina
    Cao Xizhong
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2011, 29 (06) : 507 - 512
  • [6] Analysis of procyanidins in pine bark with reversed-phase and normal-phase high-performance liquid chromatography-electrospray ionization mass spectrometry
    Karonen, M
    Loponen, J
    Ossipov, V
    Pihlaja, K
    ANALYTICA CHIMICA ACTA, 2004, 522 (01) : 105 - 112
  • [7] Analysis of cyanobacterial hepatotoxins in water samples by microbore reversed-phase liquid chromatography-electrospray ionisation mass spectrometry
    Barco, M
    Rivera, J
    Caixach, J
    JOURNAL OF CHROMATOGRAPHY A, 2002, 959 (1-2) : 103 - 111
  • [8] Ion-pair reversed-phase liquid chromatography-electrospray mass spectrometry for the analysis of underivatized small peptides
    Petritis, K
    Brussaux, S
    Guenu, S
    Elfakir, C
    Dreux, M
    JOURNAL OF CHROMATOGRAPHY A, 2002, 957 (02) : 173 - 185
  • [9] Determination of diallyldimethylammonium chloride in drinking water by reversed-phase ion-pair chromatography-electrospray ionization mass spectrometry
    Jin, F
    Hu, JY
    Yang, M
    Jin, XH
    He, WJ
    Han, HD
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1101 (1-2) : 222 - 225
  • [10] Quantification of cardiolipin by liquid chromatography-electrospray ionization mass spectrometry
    Garrett, Teresa A.
    Kordestani, Reza
    Raetz, Christian R. H.
    LIPIDOMICS AND BIOACTIVE LIPIDS: SPECIALIZED ANALYTICAL METHODS AND LIPIDS IN DISEASE, 2007, 433 : 213 - 230