摘要
The Passive Residual Heat Removal Heat Exchanger (PRHR HX) is an important part of the Passive Residual Heat Removal System (PRHRS). The C-shaped bundle is being used in the PRHR HX. A test facility of C-shaped tube immerged in a water tank was built to research the heat transfer of the PRHR HX. Through the experiments, three regions were found within a particular period of time during the heating process in the tank: natural convection region, transition region, and saturation boiling region. For the tube outside saturation boiling, comparisons of three different correlations in literatures with the experimental data were carried out. Results show that the Rohsenow correlation provides a best-estimate fit with the experimental results. For the tube outside transition region, a formulation is put forward to reduce error based on the Rohsenow subcooled boiling correlation.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Influence of pressure on boiling heat transfer outside a horizontal tube bundle
    Liu, Jinrong
    Huaxue Gongcheng/Chemical Engineering, 1998, 26 (03): : 15 - 17
  • [42] Pool boiling heat transfer in a vertical annulus with a stepped outside tube
    Kang, Myeong-Gie
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2011, 54 (23-24) : 4817 - 4822
  • [43] Boiling Heat Transfer on the Outside of A Miniature Diameter Compact Tube Bundle
    Adom, Ebenezer
    Islam, Sheikh Z.
    Kew, Peter
    WORLD CONGRESS ON ENGINEERING, WCE 2010, VOL III, 2010, : 2331 - 2336
  • [44] Analysis on the transient heat transfer process inside and outside the borehole for a vertical U-tube ground heat exchanger under short-term heat storage
    Dai, L. H.
    Shang, Y.
    Li, X. L.
    Li, S. F.
    RENEWABLE ENERGY, 2016, 87 : 1121 - 1129
  • [45] HEAT TRANSFER AUGMENTATION IN A RECTANGULAR HEAT EXCHANGER THROUGH PASSIVE HEAT TRANSFER TECHNIQUES
    Chaudhary, Manoj S.
    Rungta, Sourabh
    Himte, Rakesh
    Sakharwade, Sanjay
    Sharma, Mabhishek
    Kalbande, Vednath
    Mohan, Man
    ADVANCES AND APPLICATIONS IN MATHEMATICAL SCIENCES, 2022, 21 (09): : 5101 - 5108
  • [46] Heat transfer analysis of the passive residual heat removal system in ROSA/AP600 experiments
    Yonomoto, T
    Kukita, Y
    Schultz, RR
    NUCLEAR TECHNOLOGY, 1998, 124 (01) : 18 - 30
  • [47] Scaling distortion analysis of passive residual heat removal heat exchanger in an ACME facility during a station blackout accident
    Liu, Yusheng
    Xu, Chao
    Tan, Sichao
    Jing, Jianping
    Zhuang, Shaoxin
    Wang, Nan
    Harbin Gongcheng Daxue Xuebao/Journal of Harbin Engineering University, 2023, 44 (10): : 1689 - 1695
  • [49] Numerical simulation and analysis of enhanced heat transfer in corrugated tube heat exchanger
    Jiang, Jingzhi
    Bo, Lin
    Chen, Zhengjia
    Cui, Haiting
    Zhu, Hairong
    FOURTH INTERNATIONAL CONFERENCE ON ENERGY ENGINEERING AND ENVIRONMENTAL PROTECTION, 2020, 467
  • [50] Heat transfer analysis of a shell and tube heat exchanger operated with graphene nanofluids
    Fares, Mohammad
    AL-Mayyahi, Mohammad
    AL-Saad, Mohammed
    CASE STUDIES IN THERMAL ENGINEERING, 2020, 18 (18)